Introduction: We sought to determine and compare the effects of vasopressin, fluid resuscitation and saline placebo on haemodynamic variables and short-term survival in an abdominal vascular injury model with uncontrolled haemorrhagic shock in pigs.
Methods: During general anaesthesia, a midline laparotomy was performed on 19 domestic pigs, followed by an incision (width about 5 cm and depth 0.5 cm) across the mesenterial shaft.
Unlabelled: We have shown previously that arginine vasopressin (AVP) given during sinus rhythm increases mean arterial blood pressure (MAP) and left anterior descending (LAD) coronary artery cross sectional area. AVP was assumed to result in vasodilatation via activation of the endothelial nitric oxide system. The purpose of the present study was to assess the effects of AVP before and after NO-inhibition.
View Article and Find Full Text PDFThe effects of vasopressin on the gut in a porcine uncontrolled haemorrhagic shock model are described. In eight anaesthetised pigs, a liver laceration was performed; when haemorrhagic shock was decompensated, all animals received 0.4 IU/kg vasopressin, followed by 0.
View Article and Find Full Text PDFBag-valve-mask ventilation in an unprotected airway is often applied with a high flow rate or a short inflation time and, therefore, a high peak airway pressure, which may increase the risk of stomach inflation and subsequent pulmonary aspiration. Strategies to provide more patient safety may be a reduction in inspiratory flow and, therefore, peak airway pressure. The purpose of this study was to evaluate the effects of bag-valve-mask ventilation vs.
View Article and Find Full Text PDFReducing inspiratory flow rate and peak airway pressure may be important in order to minimise the risk of stomach inflation when ventilating an unprotected airway with positive pressure ventilation. This study was designed to yield enough power to determine whether employing an inspiratory gas flow limiting bag-valve device (SMART BAG, O-Two Medical Technologies Inc., Ontario, Canada) would also decrease the likelihood of stomach inflation in an established bench model of a simulated unintubated respiratory arrest patient.
View Article and Find Full Text PDFThe strategies to ensure safety during ventilation of an unprotected airway are limiting airway pressure and/or inspiratory flow. In this prospective, randomized study we assessed the effect of face mask ventilation with small tidal volumes in the modified mouth-to-bag resuscitator (maximal volume, 500 mL) versus a pediatric self-inflatable bag versus automatic pressure-controlled ventilation in 40 adult apneic patients during induction of anesthesia. The mouth-to-bag resuscitator requires the rescuer to blow up a balloon inside the self-inflating bag that subsequently displaces air which then flows into the patient's airway.
View Article and Find Full Text PDFWhen ventilating an unintubated patient with a standard adult self-inflating bag, high peak inspiratory flow rates may result in high peak airway pressures with subsequent stomach inflation. In a previous study we have tested a newly developed mouth-to-bag-resuscitator (max. volume, 1500 ml) that limits peak inspiratory flow, but the possible advantages were masked by excessive tidal volumes.
View Article and Find Full Text PDFUnlabelled: One approach to make ventilation safer in an unprotected airway has been to limit tidal volumes; another one might be to limit peak airway pressure, although it is unknown whether adequate tidal volumes can be delivered. Accordingly, the purpose of this study was to evaluate the quality of automatic pressure-controlled ventilation versus manual circle system face-mask ventilation regarding ventilatory variables in an unprotected airway. We studied 41 adults (ASA status I-II) in a prospective, randomized, crossover design with both devices during the induction of anesthesia.
View Article and Find Full Text PDFUnlabelled: Reducing inspiratory flow rate and peak airway pressure may be important to minimize the risk of stomach inflation when ventilating an unprotected airway with positive pressure ventilation. In this study, we assessed the effects of a standard self-inflating bag compared with a new pressure-responsive, inspiratory gas flow-limiting device (SMART BAG) on respiratory mechanics in 60 adult patients undergoing routine induction of anesthesia. Respiratory variables were measured using a pulmonary monitor.
View Article and Find Full Text PDFUnlabelled: We assessed the effects of a calcium channel blocker versus saline placebo on ventricular fibrillation mean frequency and hemodynamic variables during prolonged cardiopulmonary resuscitation (CPR). Before cardiac arrest, 10 animals were randomly assigned to receive either nifedipine (0.64 mg/kg; n = 5) or saline placebo (n = 5) over 10 min.
View Article and Find Full Text PDFUnlabelled: We sought to determine the effects of a combination of vasopressin and epinephrine on neurologic recovery in comparison with epinephrine alone and saline placebo alone in an established porcine model of prolonged cardiopulmonary resuscitation (CPR). After 4 min of cardiac arrest, followed by 3 min of basic life support CPR, 17 animals were randomly assigned to receive, every 5 min, either a combination of vasopressin and epinephrine (vasopressin [IU/kg]/epinephrine [ micro g/kg]: 0.4/45, 0.
View Article and Find Full Text PDFReducing inspiratory flow rate and peak airway pressure may be important in order to minimise the risk of stomach inflation when ventilating an unprotected airway with positive pressure ventilation. The purpose of this study was to assess the effects of a newly developed bag-valve-mask device (SMART BAG), O-Two Systems International, Ont., Canada) that limits peak inspiratory flow.
View Article and Find Full Text PDFBackground: The authors compared the effects of vasopressin fluid resuscitation on survival in a liver trauma model with uncontrolled and otherwise lethal hemorrhagic shock in pigs.
Methods: A midline laparotomy was performed on 23 domestic pigs, followed by an incision, and subsequent finger fraction across the right medial liver lobe. During hemorrhagic shock, animals were randomly assigned to receive either 0.
When ventilating an unintubated patient with a self-inflating bag, high peak inspiratory flow rates may result in high peak airway pressure with subsequent stomach inflation; this may occur frequently when rescuers without daily experience in bag-valve-mask ventilation need to perform advanced airway management. The purpose of this study was to assess the effects of a newly developed self-inflating bag (mouth-to-bag resuscitator; Ambu, Glostrup, Denmark) that limits peak inspiratory flow. A bench model simulating a patient with an unintubated airway was used, consisting of a face mask, manikin head, training lung (lung compliance, 100 ml/0.
View Article and Find Full Text PDF