Publications by authors named "Horeman T"

Objective: Cemented total hip arthroplasty (THA) demonstrates superior survival rates compared to uncemented procedures. Nevertheless, most younger patients opt for uncemented THA, as removing well-fixed bone cement in the femur during revisions is complex, particularly the distal cement plug. This removal procedure often increases the risk of femoral fracture or perforation, haemorrhage and weakening bone due to poor drill control and positioning.

View Article and Find Full Text PDF

Hospitals in Europe produce approximately 6 million tons of medical waste annually, about one-third of this originating in operating rooms. Most of it is solid waste, which can be recycled if bodily fluids do not contaminate it. Only 2-3% of hospital waste must be disposed of as infectious waste, and this is much lower than the 50-70% of garbage in the biohazard waste stream.

View Article and Find Full Text PDF
Article Synopsis
  • Hemodialysis patients often use arteriovenous fistulas (AVFs) for dialysis access, but high blood flow through AVFs can lead to complications over time.
  • A new implantable device with a magnetic ring was developed to non-invasively control an AVF valve by transmitting torque, and tests were successfully conducted on arm and sheep cadavers.
  • The prototype demonstrated effective valve closure capabilities through varying skin thicknesses, indicating its potential for non-invasive control and prompting the need for in vivo studies to evaluate its practical functionality.
View Article and Find Full Text PDF

Surgeons performing robotic-assisted laparoscopic surgery experience physical stress and overuse of shoulder muscles due to sub-optimal arm support during surgery. The objective is to present a novel design and prototype of a dynamic arm support for robotic laparoscopic surgery to evaluate its ergonomics and performance on the AdLap-VR simulation training device. The prototype was designed using the mechanical engineering design process: Technical requirements, concept creation, concept selection, 3D-design and built of the prototype.

View Article and Find Full Text PDF

Based on the success of the former "Shaft-Actuated, Tip-Articulated" SATA-Drive, a prototype robotic instrument driver for modular, steerable, laparoscopic instruments, a new driver is designed and tested to improve previously lacking features concerning cleanability, instrument adaptation, practical application and control. The design of the driver engages these issues with a modular design aimed at re-use of both the instrument and the driver, for which a set of design requirements are established. A new modular design has been developed to improve cleanability through separation of the electro-motors and the instrument mechanism which clutches the instrument.

View Article and Find Full Text PDF

In laparoscopic surgery, quality of haptic feedback is reduced compared to conventional surgery, leading to unintentional tissue damage during grasping. From the perspective of haptics, poor mechanical design of laparoscopic instrument joints induces friction and a nonlinear actuation-tip force relation. In this study, a novel laparoscopic grasper using compliant joints and a magnetic balancer is presented, and the reduction in hysteresis and friction is evaluated.

View Article and Find Full Text PDF

Background: During minimal access surgery, surgical smoke is produced which can potentially be inhaled by the surgical team, leading to several health risks. This smoke can escape from the abdominal cavity into the operating room due to trocar leakage. The trocars and insufflator that are used during surgery influence gas leakage.

View Article and Find Full Text PDF

Introduction: Robot-assisted surgery is often performed by experienced laparoscopic surgeons. However, this technique requires a different set of technical skills and surgeons are expected to alternate between these approaches. The aim of this study is to investigate the crossover effects when switching between laparoscopic and robot-assisted surgery.

View Article and Find Full Text PDF

Introduction: Although robotic-assisted surgery is increasingly performed, objective assessment of technical skills is lacking. The aim of this study is to provide validity evidence for objective assessment of technical skills for robotic-assisted surgery.

Methods: An international multicenter study was conducted with participants from the academic hospitals Heidelberg University Hospital (Germany, Heidelberg) and the Amsterdam University Medical Centers (The Netherlands, Amsterdam).

View Article and Find Full Text PDF

Mechanical stress influences scarring of a surgical wound. Several lines have been proposed for the best excision direction. It is unknown if these lines still apply when the body posture changes.

View Article and Find Full Text PDF

Introduction: The recent introduction of the European Medical Device Regulation poses stricter legislation for manufacturers developing medical devices in the EU. Many devices have been placed into a higher risk category, thus requiring more data before market approval, and a much larger focus has been placed on safety. For implantable and Class III devices, the highest risk class, clinical evidence is a necessity.

View Article and Find Full Text PDF

Introduction: Disposable instruments in healthcare have led to a significant increase of medical waste. The aim of this study is to validate the recycling of disposable Zamak laryngoscope blades into new medical components by using a new 'all-in-one' affordable reprocessing setup as alternative for die-casting.

Methods: A n "all-in-one" casting set-up was designed and built.

View Article and Find Full Text PDF

In hip arthroplasties, surgeons rely on their experience to assess the stability and balance of hip tissues when fitting the implant to their patients. During the operation, surgeons use a modular, temporary set of implants to feel the tension in the surrounding soft tissues and adjust the implant configuration. This process is naturally subjective and therefore depends on the operator.

View Article and Find Full Text PDF

The complexity of handheld steerable laparoscopic instruments (SLI) may impair the learning curve compared to conventional instruments when first utilized. This study aimed to provide the current state of interest in the use of SLI, the current use of these in daily practice and the type of training which is conducted before using SLI in the operating room (OR) on real patients. An online survey was distributed by European Association of Endoscopic Surgery (EAES) Executive Office to all active members, between January 4th and February 3rd, 2020.

View Article and Find Full Text PDF

Background: Hospitals in low resource settings (LRS) can benefit from modern laparoscopic methodologies. However, cleaning, maintenance and costs requirements play a stronger role while training and technology are less available. Steerable laparoscopic instruments have additional requirements in these settings and need extra identified adaptations in their design.

View Article and Find Full Text PDF

The success of total hip arthroplasty depends on the experience of the surgeon, and one of the ways the surgeon currently determines the final implant insertion depth is to listen to the change in audible pitch of the hammering sound. We investigated the use of vibration emissions as a novel method for insertion quality assessment. A non-invasive contact microphone-based measurement system for insertion depth estimation, fixation and fracture detection was developed using a simplified in vitro bone/implant (n = 5).

View Article and Find Full Text PDF

Background: As global use of surgical robotic systems is steadily increasing, surgical simulation can be an excellent way for robotic surgeons to acquire and retain their skills in a safe environment. To address the need for training in less wealthy parts of the world, an affordable surgical robot simulator (PoLaRS) was designed.

Methods: The aim of this pilot study is to compare learning curve data of the PoLaRS prototype with those of Intuitive Surgical's da Vinci Skills Simulator (dVSS) and to establish face- and construct validity.

View Article and Find Full Text PDF

Background: During laparoscopy, the abdominal cavity is insufflated with carbon dioxide (CO) that could become contaminated with viruses and surgical smoke. Medical staff is potentially exposed when this gas leaks into the operating room through the instruments and past trocar valves. No detailed studies currently exist that have quantified these leakage pathways.

View Article and Find Full Text PDF

Background: Face masks, also referred to as half masks, are essential to protect healthcare professionals working in close contact with patients with COVID-19-related symptoms. Because of the Corona material shortages, healthcare institutions sought an approach to reuse face masks or to purchase new, imported masks. The filter quality of these masks remained unclear.

View Article and Find Full Text PDF

The Covid-19 pandemic led to threatening shortages in healthcare of medical products such as face masks. Due to this major impact on our healthcare society an initiative was conducted between March and July 2020 for reprocessing of face masks from 19 different hospitals. This exceptional opportunity was used to study the costs impact and the carbon footprint of reprocessed face masks relative to new disposable face masks.

View Article and Find Full Text PDF

Background: Objective force- and motion-based assessment is currently lacking in laparoscopic skills curricula. This study aimed to evaluate the added value of parameter-based assessment and feedback during training.

Methods: Laparoscopy-naïve surgical residents that took part in a 3-week skills training curriculum were included.

View Article and Find Full Text PDF

Background: Robotic-assisted surgery (RAS) potentially reduces workload and shortens the surgical learning curve compared to conventional laparoscopy (CL). The present study aimed to compare robotic-assisted cholecystectomy (RAC) to laparoscopic cholecystectomy (LC) in the initial learning phase for novices.

Methods: In a randomized crossover study, medical students (n = 40) in their clinical years performed both LC and RAC on a cadaveric porcine model.

View Article and Find Full Text PDF

Aims: Resection of bone is performed in over 75% of all orthopaedic procedures and the electrically powered oscillating saw is commonly used to cut bone. Drawbacks are relatively large incisions and tissue damage due to overshooting often occur. Therefore, the goal of this study is to develop an improved bone-cutting system that has minimally invasive characteristics.

View Article and Find Full Text PDF