Publications by authors named "Horea Ilies"

Amino acid crystals are an attractive piezoelectric material as they have an ultrahigh piezoelectric coefficient and have an appealing safety profile for medical implant applications. Unfortunately, solvent-cast films made from glycine crystals are brittle, quickly dissolve in body fluid, and lack crystal orientation control, reducing the overall piezoelectric effect. Here, we present a material processing strategy to create biodegradable, flexible, and piezoelectric nanofibers of glycine crystals embedded inside polycaprolactone (PCL).

View Article and Find Full Text PDF

Protein contact maps represent spatial pairwise inter-residue interactions, providing a protein's translationally and rotationally invariant topological representation. Accurate contact map prediction has been a critical driving force for improving protein structure determination. Contact maps can also be used as a stand-alone tool for varied applications such as prediction of protein-protein interactions, structure-aware thermal stability or physicochemical properties.

View Article and Find Full Text PDF

Recent advances in materials, manufacturing, biotechnology, and microelectromechanical systems (MEMS) have fostered many exciting biosensors and bioactuators that are based on biocompatible piezoelectric materials. These biodevices can be safely integrated with biological systems for applications such as sensing biological forces, stimulating tissue growth and healing, as well as diagnosing medical problems. Herein, the principles, applications, future opportunities, and challenges of piezoelectric biomaterials for medical uses are reviewed thoroughly.

View Article and Find Full Text PDF

Measuring vital physiological pressures is important for monitoring health status, preventing the buildup of dangerous internal forces in impaired organs, and enabling novel approaches of using mechanical stimulation for tissue regeneration. Pressure sensors are often required to be implanted and directly integrated with native soft biological systems. Therefore, the devices should be flexible and at the same time biodegradable to avoid invasive removal surgery that can damage directly interfaced tissues.

View Article and Find Full Text PDF

We describe a cost-effective device that uses an off-the-shelf force transducer to measure patient bite force as a diagnostic aid in determining dental implant size, number of implants, and prosthetic design for restoring partial edentulism. The main advantages of the device are its accuracy, simplicity, modularity, ease of manufacturing, and low cost.

View Article and Find Full Text PDF

Dental implants have enabled a dramatic increase in the quality of life for many partially edentulous and edentulous patents. Immediate loading of newly placed dental implants is a recent advancement that attempts to meet patient demand. However, immediate loading of a just placed implant may induce implant failure to osseointegrate.

View Article and Find Full Text PDF

Immediate loading of newly placed dental implants is a consideration when attempting to meet patients' demands. However, immediate loading may induce implant failure to osseointegrate, particularly in the case of a patient who can generate a biting force that can reach approximately 1300 Newtons (N) in the posterior jaws. The range of biting forces that prevent osseointegration of newly placed implants is currently unknown.

View Article and Find Full Text PDF

The fatigue life of mini or small-diameter dental implants is of particular interest because these implants are used to retain and support fixed and removable dental prostheses. The fatigue life of an implant depends on both the implant itself as well as on the physical properties of the bone. However, the capability to predict the fatigue life of a newly placed implant is currently inexistent.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Notice

Message: fwrite(): Write of 34 bytes failed with errno=28 No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 272

Backtrace:

A PHP Error was encountered

Severity: Warning

Message: session_write_close(): Failed to write session data using user defined save handler. (session.save_path: /var/lib/php/sessions)

Filename: Unknown

Line Number: 0

Backtrace: