The behavior of cells and tissues in vivo is determined by the integration of multiple biochemical and mechanical signals. Of the mechanical signals, stretch has been studied for decades and shown to contribute to pathophysiological processes. Several different stretch devices have been developed for in vitro investigations of cell stretch.
View Article and Find Full Text PDFEndothelialization strategies aim at protecting the surface of cardiovascular devices upon their interaction with blood by the generation and maintenance of a mature monolayer of endothelial cells. Rational engineering of the surface micro-topography at the luminal interface provides a powerful access point to support the survival of a living endothelium under the challenging hemodynamic conditions created by the implant deployment and function. Surface structuring protocols must however be adapted to the complex, non-planar architecture of the target device precluding the use of standard lithographic approaches.
View Article and Find Full Text PDFHeart failure is a raising cause of mortality. Heart transplantation and ventricular assist device (VAD) support represent the only available lifelines for end stage disease. In the context of donor organ shortage, the future role of VAD as destination therapy is emerging.
View Article and Find Full Text PDFThe active and passive mechanical behavior of a cosmetic tightening product for skin anti-aging is investigated based on a wide range of in vivo and in vitro measurements. The experimental data are used to inform a numerical model of the attained cosmetic effect, which is then implemented in a commercial finite-element framework and used to analyze the mechanisms that regulate the biomechanical interaction between the native tissue and the tightening film. Such a film reduces wrinkles and enhances skin consistency by increasing its stiffness by 48-107% and reducing inelastic, non-recoverable deformations (-47%).
View Article and Find Full Text PDFIn this work, we report a mechanism by which stereoisomeric and twisted capsules P/M-1 direct their dynamic chirality in the presence of haloalkane guests. The capsule comprises a static, but twisted, cage that is linked to a dynamic tris(2-pyridylmethyl)amine (TPA) lid at its top. From the results of experimental (NMR spectroscopy and X-ray crystallography) and computational (DFT) studies, the TPA lid was shown to assume clockwise (+) and counterclockwise (-) folds with diastereomeric (but racemic) capsules M-1(+) and M-1(-) interconverting at a rapid rate (ΔG =9.
View Article and Find Full Text PDFBiomech Model Mechanobiol
August 2019
A total of 37 human and 33 murine skin samples were subjected to uniaxial monotonic, cyclic, and relaxation experiments. Detailed analysis of the three-dimensional kinematic response showed that skin volume is significantly reduced as a consequence of a tensile elongation. This behavior is most pronounced in monotonic but persists in cyclic tests.
View Article and Find Full Text PDFThe enantiomers of a homologous series (C6-C10) of 2-mercapto-4-alkanones were obtained by lipase-catalyzed kinetic resolution of the corresponding racemic 2-acetylthio-4-alkanones. Their configurations were assigned via vibrational circular dichroism and H NMR anisotropy based methods. Odor thresholds and odor qualities were determined by capillary gas chromatography-olfactometry using chiral stationary phases.
View Article and Find Full Text PDFSuction experiments have been extensively applied for skin characterization. In these tests the deformation behavior of superficial tissue layers determines the elevation of the skin surface observed when a predefined negative (suction) pressure history is applied. The ability of such measurements to differentiate between skin conditions is limited by the variability of the elevation response observed in repeated experiments.
View Article and Find Full Text PDFUnlabelled: A multiscale mechanics approach to the characterization of murine excisional wounds subjected to uniaxial tensile loading is presented. Local strain analysis at a physiological level of tension uncovers the presence of two distinct regions within the wound: i) a very compliant peripheral cushion and ii) a core area undergoing modest deformation. Microstructural visualizations of stretched wound specimens show negligible engagement of the collagen located in the center of a 7-day old wound; fibers remain coiled despite the applied tension, confirming the existence of a mechanically isolated wound core.
View Article and Find Full Text PDFAlthough recent progress in the field of flexible electronics has allowed the realization of biocompatible and conformable electronics, systematic approaches which combine high bendability (<3 mm bending radius), high stretchability (>3-4%), and low complexity in the fabrication process are still missing. Here, we show a technique to induce randomly oriented and customized wrinkles on the surface of a biocompatible elastomeric substrate, where Thin-Film Transistors (TFTs) and circuits (inverter and logic NAND gates) based on amorphous-IGZO are fabricated. By tuning the wavelength and the amplitude of the wrinkles, the devices are fully operational while bent to 13 μm bending radii as well as while stretched up to 5%, keeping unchanged electrical properties.
View Article and Find Full Text PDFInflammation, fibrosis and perineural adhesions with the surrounding tissue are common pathological processes following nerve injury and surgical interventions on peripheral nerves in human patients. These features can reoccur following external neurolysis, currently the most common surgical treatment for peripheral nerve scarring, thus leading to renewed nerve function impairment and chronic pain. To enable a successful evaluation of new therapeutic approaches, it is crucial to use a reproducible animal model that mimics the main clinical symptoms occurring in human patients.
View Article and Find Full Text PDFThe analysis is based on a finite element procedure to extract the contact forces between an implanted Nitinol stent and the surrounding host tissue using postoperative CT images. The methodology was applied for patients (N=46) which have undergone a TAVI procedure with the Medtronic CoreValve Revalving System (MCRS) to obtain corresponding deformation and force maps. The postoperative CT data were recorded for each patient in both systolic and diastolic phase of the heart cycle.
View Article and Find Full Text PDFBackground Aims: As new approaches for peripheral nerve regeneration are sought, there is an increasing demand for native Schwann cells for in vitro testing and/or reimplantation. Extracorporeal shockwave treatment (ESWT) is an emergent technology in the field of regenerative medicine that has also recently been shown to improve peripheral nerve regeneration.
Methods: In this study, we elucidate the effects of ESWT on Schwann cell isolation and culture.
J Mech Behav Biomed Mater
July 2016
The commercial polydimethysiloxane elastomer Sylgard(®) 184 with mixing ratio 10:1 is in wide use for biomedical research or fundamental studies of mechanobiology. In this paper, a comprehensive study of the large strain mechanical behavior of this material under multiaxial monotonic and cyclic loads, and its change during the first 26 days after preparation is reported. The equibiaxial stress response studied in inflation experiments reveals a much stiffer and more nonlinear response compared to the uniaxial and pure shear characteristics.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
May 2016
A discrete network model (DNM) to represent the mechanical behavior of the human amnion is proposed. The amnion is modeled as randomly distributed points interconnected with connector elements representing collagen crosslinks and fiber segments, respectively. This DNM is computationally efficient and allows simulations with large domains.
View Article and Find Full Text PDFTranscatheter aortic valve implantation (TAVI) is a minimally-invasive method for the treatment of aortic valve stenosis in patients with high surgical risk. Despite the success of TAVI, side effects such as paravalvular leakages can occur postoperatively. The goal of this project is to quantitatively analyze the co-occurrence of this complication and several potential risk factors such as stent shape after implantation, implantation height, amount and distribution of calcifications, and contact forces between stent and surrounding structure.
View Article and Find Full Text PDFOver the past decade, silk fibroin (SF) has been emergently used in peripheral nerve tissue engineering. Current approaches aiming at producing SF-based nerve guidance conduits (SF-NGCs) used dissolved silk based on either aqueous solutions or organic solvents. In this study, we describe a novel procedure to produce SF-NGCs: A braided tubular structure of raw Bombyx mori silk is subsequently processed with the ternary solvent CaCl2/H2O/ethanol, formic acid, and methanol to improve its mechanical and topographical characteristics.
View Article and Find Full Text PDFIntramuscular injection of the calpain inhibitor leupeptin promotes peripheral nerve regeneration in primates (Badalamente et al., 1989 [13]), and direct positive effects of leupeptin on axon outgrowth were observed in vitro (Hausott et al., 2012 [12]).
View Article and Find Full Text PDFAn approach for extracting the radial force load on an implanted stent from medical images is proposed. To exemplify the approach, a system is presented which computes a radial force estimation from computer tomography images acquired from patients who underwent transcatheter aortic valve implantation (TAVI). The deformed shape of the implanted valve prosthesis' Nitinol frame is extracted from the images.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2015
Transcatheter aortic valve implantation (TAVI) is a minimally invasive off-pump procedure to replace diseased aortic heart valves. Known complications include paravalvular leaks, atrioventricular blocks, coronary obstruction and annular rupture. Careful procedure planning including appropriate stent selection and sizing are crucial.
View Article and Find Full Text PDFArch Orthop Trauma Surg
September 2012
Introduction: The aim of our study was to investigate in vitro and in a new in vivo rat model for impaired bone healing whether a low dose BMP-2 preparation in fibrin would be equivalent or better than the combination of collagen and a high dose of BMP-2 which is currently in clinical use.
Materials And Methods: In a 14 day period we compared the in vitro release kinetics of an absorbable collagen sponge (ACS) with 72 μg rhBMP-2 in the BMPC group and fibrin matrix with 10 μg rhBMP-2 in the BMPF group. In our in vivo experiment a critical sized osteotomy was performed in the rat femur, which was filled with a spacer, inhibiting bone formation for a period of 4 weeks.
De-focused low energy extracorporeal shock wave therapy (ESWT) has been widely used in various clinical and experimental models for the treatment of painful conditions such as epicondylitis and plantar fascitis and also bone and wound healing. There is evidence that ESWT improves the metabolic activity of various cell types, e.g.
View Article and Find Full Text PDFIntroduction: Pristane-induced arthritis (PIA) in the rat has been described as an animal model of inflammatory arthritis which exhibits features similar to rheumatoid arthritis in humans, such as a chronic, destructive, and symmetrical involvement of peripheral joints. However, so far little is known about the earliest inflammatory events and their influence on locomotor behaviour during the course of PIA. To investigate this issue a detailed analysis of the pathologic changes occurring during the prodromal and early stages of PIA was performed.
View Article and Find Full Text PDF