Publications by authors named "Hoof C"

Advancements in integrated circuit (IC) technology have accelerated the miniaturization of body-worn sensors and systems, enabling long-term health monitoring. Wearable electrocardiogram (ECG), finger photoplethysmogram (PPG), and wrist-worn PPG have shown great success and significantly improved life quality. Chest-based PPG has the potential to extract multiple vital signs but requires ultra-high dynamic range (DR) IC to read out the small PPG signal among large respiration and artifacts inherent in daily life.

View Article and Find Full Text PDF

Ultrasound (US) as a wireless power transfer methodology has drawn considerable attention from the implantable medical devices (IMD) research community. Beamforming (BF) using an external transducer array patch (ETAP) has been proposed as a robust localization scheme to find a mm-sized IMD inside the human body. However, for applications focusing on deep and shallow IMDs, optimum resource utilization at the ETAP is a major power efficiency concern for energy-constrained wearable patches.

View Article and Find Full Text PDF
Article Synopsis
  • The World Health Organization recommends the use of single-dose rifampicin (SDR) for leprosy post-exposure prophylaxis (PEP), potentially reducing leprosy risk by about 50% in contacts of patients.
  • A Phase 2 trial tested a new PEP regimen that combines bedaquiline with rifampicin (BE-PEP) against the standard therapy (SDR-PEP), focusing on safety and QT interval changes in patients.
  • The trial, involving 313 participants, demonstrated that BE-PEP did not significantly differ from SDR-PEP regarding QT interval changes after treatment, indicating comparable safety profiles between the two regimens.
View Article and Find Full Text PDF
Article Synopsis
  • - Anti-mycobacterial drugs can cause QT interval prolongation, risking serious heart issues, but monitoring is tough in places with high rates of leprosy and tuberculosis.
  • - The BE-PEOPLE trial assessed the safety of a bedaquiline regimen while measuring QT intervals before and after treatment using both mobile electrocardiogram (mECG) and standard methods.
  • - Results showed that mECG is a feasible and accurate tool for QT interval tracking, with a strong correlation to traditional measurements, although automated readings were generally less precise.
View Article and Find Full Text PDF

Background And Objectives: The number of people with dementia is expected to triple to 152 million in 2050, with 90% having accompanying behavioral and psychological symptoms (BPSD). Agitation is among the most critical BPSD and can lead to decreased quality of life for people with dementia and their caregivers. This study aims to explore objective quantification of agitation in people with dementia by analyzing the relationships between physiological and movement data from wearables and observational measures of agitation.

View Article and Find Full Text PDF

Background: Post-exposure prophylaxis (PEP) using single-dose rifampicin reduces progression from infection with Mycobacterium leprae to leprosy disease. We compared effectiveness of different administration modalities, using a higher (20 mg/kg) dose of rifampicin-single double-dose rifampicin (SDDR)-PEP.

Methods: We did a cluster randomised study in 16 villages in Madagascar and 48 villages in Comoros.

View Article and Find Full Text PDF

Repeated single-point measurements of thoracic bioimpedance at a single (low) frequency are strongly related to fluid changes during hemodialysis. Extension to semi-continuous measurements may provide longitudinal details in the time pattern of the bioimpedance signal, and multi-frequency measurements may add in-depth information on the distribution between intra- and extracellular fluid. This study aimed to investigate the feasibility of semi-continuous multi-frequency thoracic bioimpedance measurements by a wearable device in hemodialysis patients.

View Article and Find Full Text PDF

Background Pulse wave velocity (PWV) is a marker of arterial stiffness and local measurements could facilitate its widescale clinical use. However, confluence of incident and early reflected waves leads to biased spatiotemporal PWV estimates. Objective We introduce the Double Gaussian Propagation Model (DGPM) to measure local PWV in consideration of wave confluence (PWV[Formula: see text]) and compare it against conventional spatiotemporal PWV (PWV[Formula: see text]), with Bramwell-Hill PWV (PWV[Formula: see text]) and blood pressure (BP) as reference measures.

View Article and Find Full Text PDF

Background And Objectives: Monitoring electrodermal activity (EDA) in daily life requires effective handling of low-quality segments, which are common in ambulatory EDA data. Although several low-quality handling methods have been implemented, systematic comparison of these methods, which requires a large annotated dataset, is lacking.

Methods: Therefore, we proposed the simulation of realistic ambulatory EDA data starting from high-quality EDA signals, which were subsequently contaminated with varying concentrations of artifacts.

View Article and Find Full Text PDF

In contrast to whole body bioimpedance, which estimates fluid status at a single point in time, thoracic bioimpedance applied by a wearable device could enable continuous measurements. However, clinical experience with thoracic bioimpedance in patients on dialysis is limited. To test the reproducibility of whole body and thoracic bioimpedance measurements and to compare their relationship with hemodynamic changes during hemodialysis, these parameters were measured pre- and end-dialysis in 54 patients during two sessions.

View Article and Find Full Text PDF

Active Inference is a recently developed framework for modeling decision processes under uncertainty. Over the last several years, empirical and theoretical work has begun to evaluate the strengths and weaknesses of this approach and how it might be extended and improved. One recent extension is the "sophisticated inference" (SI) algorithm, which improves performance on multi-step planning problems through a recursive decision tree search.

View Article and Find Full Text PDF

Speckle Plethysmography (SPG) and Photoplethysmography (PPG) are different biophotonics technologies that allow for measurement of haemodynamics. As the difference between SPG and PPG under low perfusion conditions is not fully understood, a Cold Pressor Test (CPT-60 s full hand immersion in ice water), was used to modulate blood pressure and peripheral circulation. A custom-built setup simultaneously derived SPG and PPG from the same video streams at two wavelengths (639 nm and 850 nm).

View Article and Find Full Text PDF

Background: Limited recent data exists regarding discospondylitis in dogs.

Hypothesis/objectives: (i) Describe the signalment, clinical and imaging findings, etiologic agents, treatment, and outcome of dogs with discospondylitis, (ii) determine diagnostic agreement between radiographs, CT, and MRI with regard to the presence of discospondylitis and its location, and (iii) determine risk factors for relapse and progressive neurological deterioration.

Animals: Three hundred eighty-six dogs.

View Article and Find Full Text PDF

Background: Leprosy is an ancient infectious disease with an annual global incidence of around 200,000 over the past decade. Since 2018, the World Health Organization (WHO) recommends single-dose rifampicin as post-exposure prophylaxis (SDR-PEP) for contacts of leprosy patients. The Post ExpOsure Prophylaxis for Leprosy (PEOPLE) trial evaluated PEP with a double dose of rifampicin in Comoros and Madagascar.

View Article and Find Full Text PDF

Objective: The goal was to compare Speckle plethysmography (SPG) and Photoplethysmography (PPG) with non-invasive finger Arterial Pressure (fiAP) regarding Pulse Wave Morphology (PWM) and Pulse Arrival Time (PAT).

Methods: Healthy volunteers (n = 8) were connected to a Non-Invasive Blood Pressure (NIBP) monitor providing fiAP pulse wave and PPG from a clinical transmission-mode SpO finger clip. Biopac recorded 3-lead ECG.

View Article and Find Full Text PDF

Background And Objectives: Agitation, a critical behavioral and psychological symptom in dementia, has a profound impact on a patients' quality of life as well as their caregivers'. Autonomous and objective characterization of agitation with multimodal systems has the potential to capture key patient responses or agitation triggers.

Research Design And Methods: In this article, we describe our multimodal system design that encompasses contextual parameters, physiological parameters, and psychological parameters.

View Article and Find Full Text PDF

In proteomics, the need to precisely examine the protein compounds of small samples, requires sensitive analytical methods which can separate and enrich compounds with high precision. Current techniques require a minimal analysis time to obtain satisfactory compound separation where longer analysis time means better separation of compounds. But, molecular diffusion will create broadening of the separated compound bands over time, increasing the peak width, and thus reducing the resolution and the enrichment.

View Article and Find Full Text PDF

Stressful life experiences may jeopardize the healthy development of children. To improve interventions, more knowledge is needed on the perception of stress by children. In adults, stress is regarded as a state of low valence and high arousal.

View Article and Find Full Text PDF

Background: Chronic stress and depressive symptoms have both been linked to increased heart rate (HR) and reduced HR variability. However, up to date, it is not clear whether chronic stress, the mechanisms intrinsic to depression or a combination of both cause these alterations. Subclinical cases may help to answer these questions.

View Article and Find Full Text PDF

Background: Although both speckle plethysmography (SPG) and photoplethysmography (PPG) examine pulsatile changes in the vasculature using opto-electronics, PPG has a long history, whereas SPG is relatively new and less explored. The aim of this study was to compare the effects of integration time and light-source coherence on signal quality and waveform morphology for reflective and transmissive rSPG and rPPG. Methods: (A) Using time-domain multiplexing, we illuminated 10 human index fingers with pulsed lasers versus LEDs (both at 639 and 850 nm), in transmissive versus reflective mode.

View Article and Find Full Text PDF

The ability to objectively measure aspects of performance and behavior is a fundamental pillar of digital health, enabling digital wellness products, decentralized trial concepts, evidence generation, digital therapeutics, and more. Emerging multimodal technologies capable of measuring several modalities simultaneously and efforts to integrate inputs across several sources are further expanding the limits of what digital measures can assess. Experts from the field of digital health were convened as part of a multi-stakeholder workshop to examine the progress of multimodal digital measures in two key areas: detection of disease and the measurement of meaningful aspects of health relevant to the quality of life.

View Article and Find Full Text PDF

Changes in respiratory rate have been found to be one of the early signs of health deterioration in patients. In remote environments where diagnostic tools and medical attention are scarce, such as deep space exploration, the monitoring of the respiratory signal becomes crucial to timely detect life-threatening conditions. Nowadays, this signal can be measured using wearable technology; however, the use of such technology is often hampered by the low quality of the recordings, which leads more often to wrong diagnosis and conclusions.

View Article and Find Full Text PDF

Background: There are 1.1 billion smokers worldwide, and each year, more than 8 million die prematurely because of cigarette smoking. More than half of current smokers make a serious quit every year.

View Article and Find Full Text PDF

Technological advancements and miniaturization of wearable sensors have enabled long-term pervasive physiological monitoring. Wrist-worn photoplethysmography (PPG) sensors, although quite popular owing to their form factor, suffer from poor signal quality in ambulatory settings due to motion artifacts. This affects the reliable estimation of vital cardiac parameters, especially during motion/activities of daily living.

View Article and Find Full Text PDF

Continuous and non-invasive cardiovascular monitoring has gained attention due to the miniaturization of wearable devices. Particularly, wrist-worn photoplethysmography (PPG) sensors present an alternative to electrocardiogram recording for heart rate (HR) monitoring as it is cheaper and non-intrusive for daily activities. Yet, the accuracy of PPG measurements is heavily affected by motion artifacts which are inherent to ambulatory environments.

View Article and Find Full Text PDF