Biofunctional magnetic nanoparticles (MNPs) have been widely applied in biomedical engineering. MNPs are used as a contrast medium in magnetic imaging. Current methods of magnetic imaging, such as magnetic particle imaging and magnetic relaxometry, use small amounts of MNPs at target points far from the surface of the patient's body; these methods always consume considerable power to produce magnetic fields of high uniformity or gradient excitations.

View Article and Find Full Text PDF

After a needle biopsy, immunohistochemistry is generally used to stain tissue slices for clinically confirming tumours. Currently, tissue slices are immersed in a bioprobe-linked fluorescent reagent for several minutes, washed to remove the unbound reagent, and then observed using a fluorescence microscope. However, the observation must be performed by experienced pathologists, and producing a qualitative analysis is time consuming.

View Article and Find Full Text PDF

We report herein an investigation into dynamic magnetic clustering that occurs during immunoassays as biofunctionalized magnetic nanoparticles (BMNs) become associated with biotargets. We measure the dynamic effective relaxation time τeff(t) and use scanning electron microscopy (SEM) and transmission electron microscopy (TEM) to investigate the C-reactive protein (CRP) as it associates with the BMN Fe3O4-antiCRP to form the magnetic cluster Fe3O4-antiCRP-CRP. The results indicate that τeff(t) increases with increasing association time.

View Article and Find Full Text PDF

In this work, we report the use of bio-functionalized magnetic nanoparticles (BMNs) and dynamic magnetic resonance (DMR) to characterize the time-dependent spin-spin relaxation time for sensitive bio-detection. The biomarkers are the human C-reactive protein (CRP) while the BMNs are the anti-CRP bound onto dextran-coated Fe3O4 particles labeled as Fe3O4-antiCRP. It was found the time-dependent spin-spin relaxation time, T2, of protons decreases as time evolves.

View Article and Find Full Text PDF

Background: Stress nuclear myocardial perfusion imaging (MPI) is an established method for diagnosis and prognosis of coronary artery disease (CAD). However, radiation exposure limits its clinical application. Magnetocardiography (MCG) has been proposed as a non-contact, rapid and non-radiation technique with high reproducibility.

View Article and Find Full Text PDF

Background: Patients with transfusion-dependent beta-thalassemia major (TM) are at risk for myocardial iron overload and cardiac complications. Spatial repolarization heterogeneity is known to be elevated in patients with certain cardiac diseases, but little is known in TM patients. The purpose of this study was to evaluate spatial repolarization heterogeneity in patients with TM, and to investigate the relationships between spatial repolarization heterogeneity, cardiac iron load, and adverse cardiac events.

View Article and Find Full Text PDF

Although the biomarker carcinoembryonic antigen (CEA) is expressed in colorectal tumors, the utility of an anti-CEA-functionalized image medium is powerful for in vivo positioning of colorectal tumors. With a risk of superparamagnetic iron oxide nanoparticles (SPIONPs) that is lower for animals than other material carriers, anti-CEA-functionalized SPIONPs were synthesized in this study for labeling colorectal tumors by conducting different preoperatively and intraoperatively in vivo examinations. In magnetic resonance imaging (MRI), the image variation of colorectal tumors reached the maximum at approximately 24 h.

View Article and Find Full Text PDF

A highly sensitive immunoassay, the immunomagnetic reduction, is used to measure several biomarkers for plasma that is related to Alzheimer's disease (AD). These biomarkers include Aβ-40, Aβ-42, and tau proteins. The samples are composed of four groups: healthy controls (n=66), mild cognitive impairment (MCI, n=22), very mild dementia (n=23), and mild-to-serve dementia, all due to AD (n=22).

View Article and Find Full Text PDF

To perform a rat experiment using a high-temperature superconducting (HTS) surface resonator, a cryostat is essential to maintain the rat's temperature. In this work, a compact temperature-stable HTS cryo-system, keeping animal rectal temperature at 37.4°C for more than 3 hours, was successfully developed.

View Article and Find Full Text PDF

Background: Electrophysiological information as well as anatomic information are important for the detection of coronary artery lesions. The aim of this study was to assess the efficacy of resting magnetocardiography (MCG) in stable coronary artery disease (CAD) and cardiac allograft vasculopathy (CAV).

Methods And Results: MCG and coronary angiography were performed within 1 month in 75 patients with suspected CAD and in 26 subjects after orthotopic heart transplantation (OHT).

View Article and Find Full Text PDF

Magnetic nanoparticles (MNPs) of Fe(3)O(4) have been widely applied in many medical fields, but few studies have clearly shown the outcome of particles following intravenous injection. We performed a magnetic examination using scanning SQUID biosusceptometry (SSB). Based on the results of SSB analysis and those of established in vitro nonmagnetic bioassays, this study proposes a model of MNP metabolism consisting of an acute metabolic phase with an 8 h duration that is followed by a chronic metabolic phase that continues for 28 d following MNP injection.

View Article and Find Full Text PDF

In this study, we report the spin-lattice relaxation rate of hepatocellular carcinoma (HCC) and normal liver tissue in rats using a high-T(c) superconducting quantum interference device (SQUID) based nuclear magnetic resonance (NMR) spectrometer. The resonance spectrometer used for discriminating liver tumors in rats via the difference in longitudinal relaxation time in low magnetic fields was set up in a compact and portable magnetic shielding box. The frequency-domain NMR signals of HCC tissues and normal liver tissues were analyzed to study their respective longitudinal relaxation rate T(1) (-1).

View Article and Find Full Text PDF

With antibody-mediated magnetic nanoparticles (MNPs) applied in cancer examinations, patients must pay at least twice for MNP reagents in immunomagnetic reduction (IMR) of in vitro screening and magnetic resonance imaging (MRI) of in vivo tests. This is because the high maintenance costs and complex analysis of MRI have limited the possibility of in vivo screening. Therefore, this study proposes novel methods for in vivo screening of tumors by examining the AC susceptibility of bound MNPs using scanning superconducting-quantum-interference-device (SQUID) biosusceptometry (SSB), thereby demonstrating high portability and improved economy.

View Article and Find Full Text PDF

Background: Magnetic nanoparticles biofunctionalized with antibodies are able to recognize and bind to the corresponding antigens. In this work, anti-C-reactive protein (CRP) antibody was covalently conjugated onto the surface of magnetic nanoparticles to label CRP specifically in serum.

Methods: The level of serum CRP was detected by immunomagnetic reduction (IMR) assay, which identifies the changes in the magnetic signal representing the level of interaction between antibody-conjugated magnetic nanoparticles and CRP proteins.

View Article and Find Full Text PDF

This study examines the enlargement of the field of view (FOV) and the maintenance of a high signal-to-noise ratio (SNR) through the use of two high-temperature superconducting (HTS) resonators in a 3T MRI. Two Bi(2)Sr(2)Ca(2)Cu(3)O(x) (Bi-2223) surface resonators, each of 4-cm diameter, were used in a 3T MRI. Professionally made copper resonators operate at 300 K, but each Bi-2223 resonator, operated at 77 K and demonstrated a 3.

View Article and Find Full Text PDF

Magnetic nanoparticles biofunctionalized with antibodies against β-amyloid-40 (Aβ-40) and Aβ-42, which are promising biomarkers related to Alzheimer's disease (AD), were synthesized. We characterized the size distribution, saturated magnetizations, and stability of the magnetic nanoparticles conjugated with anti-Aβ antibody. In combination with immunomagnetic reduction technology, it is demonstrated such biofunctionalized magnetic nanoparticles are able to label Aβs specifically.

View Article and Find Full Text PDF

For preoperative and intraoperative detection of tumor distribution, numerous multimodal contrast agents, such as magnetic nanoparticles (MNPs) with several examination indicators, are currently in development. However, complex materials, configuration, and cost are required for multimodal contrast agents, accompanied by a high possibility of toxicity and low popularity in clinics. Nevertheless, the magnetic labeling of MNPs using bioprobes should be feasible not only in preoperative magnetic resonance imaging (MRI), but also in intraoperative examination based on other magnetic properties.

View Article and Find Full Text PDF

Some previous reports have already shown the characterizations of immunomagnetic reduction (IMR). The assay technology involves the utilities of biofunctionalized magnetic nanoparticles to label target biomolecules. However, the detection threshold and interference tests for IMR have not been investigated in detail.

View Article and Find Full Text PDF

High temperature superconducting (HTS) surface resonators have been used as a low loss RF receiver resonator for improving magnetic resonance imaging image quality. However, the application of HTS surface resonators is significantly limited by their filling factor. To maximize the filling factor, it is desirable to have the RF resonator wrapped around the sample so that more nuclear magnetic dipoles can contribute to the signal.

View Article and Find Full Text PDF

To achieve early-stage diagnosis, a high-sensitivity assay method is needed. As a biomarker, vascular endothelial growth factor (VEGF) has played a growing role in diagnosing and treating hepatocellular carcinoma (HCC). In this work, an immunomagnetic reduction (IMR) through bio-functionalized magnetic nanoparticles and a high-temperature superconducting-quantum-interference-device magnetometer were utilized for quantitative detection of low-concentration VEGF in serum from rats with HCC.

View Article and Find Full Text PDF

In this paper, an instrumentation of the Earth's field nuclear magnetic resonance (EFNMR) inside a laboratory is presented. A lock-in analysis (LIA) technique was proposed to enhance the signal-to-noise ratio (SNR). A SNR of 137.

View Article and Find Full Text PDF

We use a heterodyne Mach-Zehnder interferometer to simultaneously and simply measure the complex refractive index by only normal incidence on the specimen, instead of using a complicated measurement procedure or instrument that only measures the real or imaginary part of the complex refractive index. To study the tiny variation of the complex refractive index, the small complex refractive-index variation of a rare-concentration magnetic-fluid thin film, due to a weak field of less than 200 Oe, was processed by this interferometer. We also present the wavelength trend of the complex refractive index of magnetic fluids to verify the appearance of the slight change in a small wavelength range.

View Article and Find Full Text PDF
Article Synopsis
  • - This study investigates a new method for gene transfer using Fe3O4 nanoparticles to introduce DNA expression vectors into mammalian cells, specifically focusing on the EGFP gene.
  • - Four different delivery systems were tested, including liposome-enveloped DNA with and without the nanoparticles, and it was found that Fe3O4 nanoparticles allow for effective gene transfection without causing cytotoxicity.
  • - The results indicate that applying a magnetic field significantly increases the efficiency of this method, enabling better gene delivery to osteoblast cells compared to traditional methods.
View Article and Find Full Text PDF

High-temperature superconducting (HTS) coil is one of the best ways to increase the signal-to-noise ratio (SNR). Bi2Sr2Ca2Cu3Ox (Bi-2223) tapes were suitable to use because of the easier fabrications and lower cost. In this study, we built HTS Bi-2223 tape coils and demonstrated that the SNR of using the HTS tape coil was 3 or 4 folds higher than that of the traditional copper coil for a rat brain MR study.

View Article and Find Full Text PDF

One way to reduce receiving coil noise in MRI scans is using non-resistive high-temperature superconducting (HTS) coils [1]. They show advantages of much lower cost and easier fabrication over HTS thin iilm coils. In this work, we built a 200mm in diameter Bi2Sr2Ca2Cu3Ox(Bi-2223) tape HTS RF coil and demonstrated that the SNR of using the HTS tape coil was 2.