A novel ionization technique named medium vacuum chemical ionization (MVCI) mass spectrometry (MS), which is a chemical ionization using oxonium (HO) and hydroxide (OH) formed from water, has excellent compatibility with the supercritical fluid extraction (SFE)/supercritical fluid chromatography (SFC). We have studied a method to determine free fatty acids (FFAs) in a small section of bovine liver tissue using SFE/SFC-MVCI MS analysis without further sample preparation. A series of FFA molecules interact with the C18 stationary phase, exhibiting broad chromatographic peaks when using a non-modified CO as the mobile phase.
View Article and Find Full Text PDFThe gain of the microchannel plate temporally drops after an ion initiates an electron avalanche. Electron multiplication was expected to deplete the charge from the microchannel wall and produce the depleted charge (wall charge). Moreover, it was reported that the gain drop occurred not only in the activated channels, where the electrons are multiplied, but also in the surrounding channels.
View Article and Find Full Text PDFWe have developed a rapid and sensitive analytical method for α-tocopherol and its oxidative products by combining online hyphenation of supercritical fluid extraction-supercritical fluid chromatography (SFC) with proton transfer reaction (PTR) ionization mass spectrometry (MS). α-Tocopherol is a well-known antioxidant that plays a vital role in the antioxidant defense system in plant cells. However, studies on the cellular mechanisms of α-tocopherol have been limited owing to the lack of a rapid analytical method, which limits the comparison of plant cells incubated in various conditions.
View Article and Find Full Text PDFProton-transfer-reaction (PTR) mass spectrometry (MS), a widely used method for detecting trace-levels of volatile organic compounds in gaseous samples, can also be used for the analysis of small non-volatile molecules by using supercritical fluid as a transporter for the molecules. Supercritical fluid extraction (SFE) is a method that permits lipophilic compounds to be rapidly and selectively extracted from complex matrices. The combination of the high sensitivity of PTR MS with the SFE is a potentially novel method for analyzing small molecules in a single cell, particularly for the analysis of lipophilic compounds.
View Article and Find Full Text PDFThe application of proton transfer ionization reaction mass spectrometry (PTR MS) combined with microscale supercritical fluid extraction (SFE) and supercritical fluid chromatography (SFC) aiming to quantitate single-cell fatty acid analysis levels was investigated. Using a microscale extraction vessel, the obtained low limits of quantitation (LLOQs) of arachidonic acid and arachidic acid were 1.2 and 2.
View Article and Find Full Text PDFUnderstanding the growth status of fruits can enable precise growth management and improve the product quality. Previous studies have rarely used deep learning to observe changes over time, and manual annotation is required to detect hidden regions of fruit. Thus, additional research is required for automatic annotation and tracking fruit changes over time.
View Article and Find Full Text PDFAs the COVID-19 pandemic persists, pregnant women have been increasingly affected worldwide. Women during the last trimester of pregnancy are susceptible to severe COVID-19, and there are many challenges towards its treatment. Monoclonal antibody treatment (MAT) is approved for COVID-19 patients to reduce disease severity.
View Article and Find Full Text PDFA time-of-flight mass spectrometer that uses a closed-orbit flight path can achieve a high mass resolving power and a high mass accuracy with a small instrument footprint. It has long been known that a drawback to a closed flight path is an obtained spectrum may contain peaks by ions at a different number of laps. A lower / ion may overtake higher / ions, resulting in the peak being superimposed on an acquired mass spectrum; therefore, such a mass bandwidth of the analyzer is limited to a narrow range given the current situation.
View Article and Find Full Text PDFProton-transfer-reaction (PTR) mass spectrometry (MS) is capable of detecting trace-level volatile organic compounds (VOCs) in gaseous samples in real time. Therefore, PTR-MS has become a popular method in many different study areas. Most of the currently reported PTR-MS applications are designed to determine volatile compounds.
View Article and Find Full Text PDFUse of a two-stage microchannel plate (MCP) detector is common in time-of-flight (TOF) mass spectrometry because it shows excellent time resolution with sufficient gains. However, the gain drops significantly when the detector detects intense ion fluxes, such as matrix ions, by matrix-assisted laser desorption/ionization mass spectrometry. As a result, significant ion signals corresponding to analytes, such as proteins, are hidden, thereby hampering the mass spectral interpretation.
View Article and Find Full Text PDFUsing a multi-turn time-of-flight (TOF) mass spectrometer, we have extracted a single xenon isotope ion, Xe, from its orbit at given a lap number without disturbing the rest of isotopes. After detecting the Xe at 20 laps, the rest of the xenon isotope spectrum was obtained at 30 laps, which generated a TOF spectrum where the TOF difference between Xe and Xe was 87.4 μs while Xe and Xe were 1.
View Article and Find Full Text PDFSimultaneous ion counting and waveform averaging implemented on a field-programmable gate array compiled with a high-speed digitizer was applied to ultraperformance liquid chromatography-time-of-flight mass spectrometric analysis of sulfa drugs. Ion counting was carried out by a "Peak Detection" (PKD) function that works together with signal averaging (AVG). Sulfadimidine (SDD) and sulfadimethoxine (SDMX) were measured in human serum (HS) model sample matrix.
View Article and Find Full Text PDFAn 82-year-old woman was admitted to our hospital with heart failure. Coronary angiography revealed one anatomically normal right coronary artery and three left coronary arteries (LCA-1, LSA-2, and LSA-3) separately originating from the right sinus of Valsalva, comprising multiple atherosclerotic lesions. LCA-1 became the obtuse marginal branch after branching off into the septal branches.
View Article and Find Full Text PDFTwo different types of data acquisition methods, "averaging mode" and "ion-counting mode", have been used in a time-of-flight (TOF) mass spectrometry. The most common method is an averaging mode that sums waveform signals obtained from each flight cycle. While it is possible to process many ions arriving at the same TOF in one flight cycle, low-abundance ions are difficult to measure because ion signals are overwhelmed by noises from the detection system.
View Article and Find Full Text PDFEur J Mass Spectrom (Chichester)
December 2017
A simple, effective accurate mass assignment procedure for a time-of-flight mass spectrometer is desirable. External mass calibration using a mass calibration standard together with an internal mass reference (lock mass) is a common technique for mass assignment, however, using polynomial fitting can result in mass-dependent errors. By using the multi-turn time-of-flight mass spectrometer infiTOF-UHV, we were able to obtain multiple time-of-flight data from an ion monitored under several different numbers of laps that was then used to calculate a mass calibration equation.
View Article and Find Full Text PDFSintering is a common process during which nanoparticles and microparticles are bonded, leading to the shrinkage of interstitial pore space. Understanding morphological evolution during sintering is a challenge, because pore structures are elusive and very complex. A topological model of sintering is presented here, providing insight for understanding 3-D microstructures observed by X-ray microtomography.
View Article and Find Full Text PDFHelium isotope determination may be useful in measuring volcanic activity and issuing earlier warnings of possible eruptions. A method is presented for measuring the He/He ratio in a gas sample using a multiturn time-of-flight mass spectrometer "infiTOF". In contrast to conventional waveform averaging, peaks are determined by counting ion pulses from each time-of-flight trigger.
View Article and Find Full Text PDFMicrofold (M) cells in the follicle-associated epithelium (FAE) of Peyer's patches contribute to the mucosal immune response by the transcytosis of microorganisms. The mechanism by which M cells take up microorganisms, and the functional proteins by which they do this, are not clear. In order to explore one such protein, we developed a 2H5-F3 monoclonal antibody (2H5-F3 mAb) through its binding to bovine M cells, and identified the antibody reactive molecule as cyclophilin A (Cyp-A).
View Article and Find Full Text PDFEur J Mass Spectrom (Chichester)
May 2015
Rapid acquisition of time-of-flight (TOF) spectra from fewer acquisitions on average was investigated using the newly introduced 12-bit digitizer, Keysight model U5303A. This is expected to achieve a spectrum acquisition 32 times faster than the commonly used 8-bit digitizer for an equal signal-to-noise (S/N) ratio. Averaging fewer pulses improves the detection speed and chromatographic separation performance.
View Article and Find Full Text PDFAfrican elephant mitochondrial (mt) DNA follows a distinctive evolutionary trajectory. As females do not migrate between elephant herds, mtDNA exhibits low geographic dispersal. We therefore examined the effectiveness of mtDNA for assigning the provenance of African elephants (or their ivory).
View Article and Find Full Text PDFD-Amino acid oxidase (DAAO) catalyzes the oxidation of d-amino acids including d-serine, a coagonist of the N-methyl-d-aspartate receptor. We identified a series of 4-hydroxypyridazin-3(2H)-one derivatives as novel DAAO inhibitors with high potency and substantial cell permeability using fragment-based drug design. Comparisons of complex structures deposited in the Protein Data Bank as well as those determined with in-house fragment hits revealed that a hydrophobic subpocket was formed perpendicular to the flavin ring by flipping Tyr224 in a ligand-dependent manner.
View Article and Find Full Text PDFAn 81-year-old woman was admitted to our hospital with acute heart failure. A coronary stent was implanted in the left circumflex artery (LCX) on day 3, and elective percutaneous coronary intervention for stenosis in the left anterior descending artery (LAD) was planned for day 10. However, 15 minutes after heparin administration, sudden thrombotic occlusion occurred first in the LAD and then in the LCX.
View Article and Find Full Text PDF