Publications by authors named "Hollis J Batterman"

Some sera tested for 1-3-beta-D-glucan to identify invasive fungal infections exhibit interference. To assess interference transience, we evaluated results for 426 patients with an interference sample followed by a later sample. Interference was transient for 73% of patients (later sample negative or positive); median time between samples was 8 days.

View Article and Find Full Text PDF
Article Synopsis
  • The study analyzed the effectiveness of two tests (DiaSorin and HerpeSelect) for detecting herpes simplex virus type 2 (HSV-2), focusing on discrepancies between their results.
  • Out of 2305 samples that tested positive with DiaSorin, 411 (about 18%) were negative when retested with HerpeSelect, indicating a high false positive rate in the DiaSorin results.
  • The findings suggest that many low-positive results from the DiaSorin test may not be reliable and highlight the need for confirmatory testing for these cases using both testing methods.
View Article and Find Full Text PDF
Article Synopsis
  • * Consensus interpretations (positive or negative) were established when at least three out of the four assays agreed, showing very high agreement rates among the assays (96.7% to 100% for negatives and 94.3% to 100% for positives).
  • * Although some false positives were identified, they were infrequent, confirming that the assays are reliable for detecting SARS-CoV-2 IgG antibodies.
View Article and Find Full Text PDF

The global coronavirus (CoV) disease 2019 (COVID-19) pandemic has resulted in a worldwide shortage of viral transport media and raised questions about specimen stability. The objective of this study was to determine the stability of severe acute respiratory syndrome CoV 2 (SARS-CoV-2) RNA in specimen transport media under various storage conditions. Transport media tested included UTM, UTM-RT, ESwab, M4, and saline (0.

View Article and Find Full Text PDF

CDC guidelines recommend confirmatory testing of sera with low-positive indices (1.10-3.50) in the HerpeSelect® (HSLT) HSV-2 IgG screening assay.

View Article and Find Full Text PDF

The objective of this study was to provide real-world clinical laboratory-based data to supplement Centers for Disease Control and Prevention (CDC) reporting of Q fever. We analysed titre results of specimens submitted to a large US clinical laboratory for Coxiella burnetii IgG antibody testing from 2010 through 2016. Presumptive Q fever was defined as acute (phase II IgG titre ⩾1:128, phase I titre <1:1024) or chronic (phase I IgG titre ⩾1:1024), based on the results from a single serum specimen.

View Article and Find Full Text PDF

We present a case of JC polyomavirus (JCV)-associated nephropathy (PyVAN) in an asymptomatic deceased-donor kidney transplant recipient. Despite the presence of viral cytopathic effect in the kidney biopsy and positive BK polyomavirus (BKV) in situ hybridization (ISH), BKV real-time polymerase chain reaction (PCR) results of plasma and urine were negative. JCV ISH was performed and was found to be positive.

View Article and Find Full Text PDF

The Simplexa™ Group A Strep Direct assay is intended for use on the Integrated Cycler for detection of Group A Streptococcus (GAS) directly from throat swabs that have not undergone nucleic acid extraction. A prospective study of 1352 samples in 4 geographically diverse sites showed an overall prevalence of GAS of 15.4%.

View Article and Find Full Text PDF

Since first reported in the Americas in December 2013, chikungunya virus (CHIKV) infections have been documented in travelers returning from the Caribbean, with many cases identified by CHIKV antibody and/or RNA testing at our laboratory. We used our large data set to characterize the relationship between antibody titers and RNA detection and to estimate IgM persistence. CHIKV RNA was measured by nucleic acid amplification and CHIKV IgG/IgM by indirect immunofluorescence.

View Article and Find Full Text PDF