Publications by authors named "Holger Muller"

The methoxy radical, CHO, has long been studied experimentally and theoretically by spectroscopists because it displays a weak Jahn-Teller effect in its electronic ground state, combined with a strong spin-orbit interaction. In this work, we report an extension of the measurement of the pure rotational spectrum of the radical in its vibrational ground state in the submillimeter-wave region (350-860 GHz). CHO was produced by H-abstraction from methanol using F atoms, and its spectrum was probed in absorption using an association of source-frequency modulation and Zeeman modulation spectroscopy.

View Article and Find Full Text PDF

In this paper, we report on the sensing role of the 1,2,3-triazol unit in a 1,4-diyl arrangement in a fully π-conjugated fluorescent probe 1 (cf. Scheme 1) towards the fluorometric detection of 3d metal ions. The 1,2,3-triazol-1,4-diyl-fluoroionophore 1 was designed in a donor(D)-acceptor(A) arrangement with a 1,2,3-triazol unit as a π-linker between a terpyridine (A) ionophore and a diethylaminocoumarin (D) fluorophore to study the fluorescence behavior towards the divalent 3d metal ions Mn, Fe, Co, Ni, Cu and Zn.

View Article and Find Full Text PDF

Objectives: Serum total bile acid (TBA) levels are frequently assessed in clinical routine for the early detection of hepatobiliary dysfunction. However, the comparability of current 5th-generation TBA cycle assays based on 3α-hydroxysteroid dehydrogenase (3α-HSD) and their ability to quantify individual bile acids has not been systematically addressed.

Methods: Patient serum samples (n=60) across the diagnostically relevant TBA range (1-200 μmol/L) were analyzed using five TBA routine assays from Abbott, DiaSys, Diazyme, Beijing Strong (BSBE) and Randox on the same analyzer (BioMajesty JCA-BM6010/C).

View Article and Find Full Text PDF

For decades since the development of phase-contrast optical microscopy, an analogous approach has been sought for maximizing the image contrast of weakly-scattering objects in transmission electron microscopy (TEM). The recent development of the laser phase plate (LPP) has demonstrated that an amplified, focused laser standing wave provides stable, tunable phase shift to the high-energy electron beam, achieving phase-contrast TEM. Building on proof-of-concept experimental demonstrations, this paper explores design improvements tailored to biological imaging.

View Article and Find Full Text PDF

Deployment of ultracold atom interferometers (AI) into space will capitalize on quantum advantages and the extended freefall of persistent microgravity to provide high-precision measurement capabilities for gravitational, Earth, and planetary sciences, and to enable searches for subtle forces signifying physics beyond General Relativity and the Standard Model. NASA's Cold Atom Lab (CAL) operates onboard the International Space Station as a multi-user facility for fundamental studies of ultracold atoms and to mature space-based quantum technologies. We report on pathfinding experiments utilizing ultracold Rb atoms in the CAL AI.

View Article and Find Full Text PDF

Despite being the dominant force of nature on large scales, gravity remains relatively elusive to precision laboratory experiments. Atom interferometers are powerful tools for investigating, for example, Earth's gravity, the gravitational constant, deviations from Newtonian gravity and general relativity. However, using atoms in free fall limits measurement time to a few seconds, and much less when measuring interactions with a small source mass.

View Article and Find Full Text PDF

Although defocus can be used to generate partial phase contrast in transmission electron microscope images, cryo-electron microscopy (cryo-EM) can be further improved by the development of phase plates which increase contrast by applying a phase shift to the unscattered part of the electron beam. Many approaches have been investigated, including the ponderomotive interaction between light and electrons. We review the recent successes achieved with this method in high-resolution, single-particle cryo-EM.

View Article and Find Full Text PDF

Although defocus can be used to generate partial phase contrast in transmission electron microscope images, cryo-electron microscopy (cryo-EM) can be further improved by the development of phase plates which increase contrast by applying a phase shift to the unscattered part of the electron beam. Many approaches have been investigated, including the ponderomotive interaction between light and electrons. We review the recent successes achieved with this method in high-resolution, single-particle cryo-EM.

View Article and Find Full Text PDF

Electrochromic optical recording (ECORE) is a label-free method that utilizes electrochromism to optically detect electrical signals in biological cells with a high signal-to-noise ratio and is suitable for long-term recording. However, ECORE usually requires a large and intricate optical setup, making it relatively difficult to transport and to study specimens on a large scale. Here, we present a Compact ECORE (CECORE) apparatus that drastically reduces the spatial footprint and complexity of the ECORE setup whilst maintaining high sensitivity.

View Article and Find Full Text PDF

The capability to reach ultracold atomic temperatures in compact instruments has recently been extended into space. Ultracold temperatures amplify quantum effects, whereas free fall allows further cooling and longer interactions time with gravity-the final force without a quantum description. On Earth, these devices have produced macroscopic quantum phenomena such as Bose-Einstein condensates (BECs), superfluidity, and strongly interacting quantum gases.

View Article and Find Full Text PDF

Herein, we report on highly Ba selective fluorescence sensing in water by a fluorescent probe consisting of a benzo-21-crown-7 as a Ba binding unit (ionophore) and a tetramethylated BODIPY fluorophore as a fluorescence reporter. This fluorescent probe showed a Ba induced fluorescence enhancement (FE) by a factor of 12±1 independently of the pH value and a high Ba sensitivity with a limit of detection (LOD) of (17.2±0.

View Article and Find Full Text PDF

We identify thermal magnetic field fluctuations, caused by thermal electron motion ("Johnson noise") in electrically conductive materials, as a potential resolution limit in transmission electron microscopy with a phase plate. Specifically, resolution loss can occur if the electron diffraction pattern is magnified to extend phase contrast to lower spatial frequencies, and if conductive materials are placed too close to the electron beam. While our initial implementation of a laser phase plate (LPP) was significantly affected by these factors, a redesign eliminated the problem and brought the performance close to the expected level.

View Article and Find Full Text PDF

We identify thermal magnetic field fluctuations, caused by thermal electron motion ("Johnson noise") in electrically conductive materials, as a potential resolution limit in transmission electron microscopy with a phase plate. Specifically, resolution loss can occur if the electron diffraction pattern is magnified to extend phase contrast to lower spatial frequencies, and if conductive materials are placed too close to the electron beam. While our initial implementation of a laser phase plate (LPP) was significantly affected by these factors, a redesign eliminated the problem and brought the performance close to the expected level.

View Article and Find Full Text PDF

Since SARS-CoV-2 emerged in December 2019 in Wuhan, the resulting pandemic has paralyzed the economic and cultural life of the world. Variants of concern (VOC) strongly increase pressure on public health systems. Rapid, easy-to-use, and cost-effective assays are essential to manage the pandemic.

View Article and Find Full Text PDF

Optical recording based on voltage-sensitive fluorescent reporters allows for spatial flexibility of measuring from desired cells, but photobleaching and phototoxicity of the fluorescent labels often limit their sensitivity and recording duration. Voltage-dependent optical absorption, rather than fluorescence, of electrochromic materials, would overcome these limitations to achieve long-term optical recording of bioelectrical signals. Electrochromic materials such as PEDOT:PSS possess the property that an applied voltage can either increase or decrease the light absorption depending on the wavelength.

View Article and Find Full Text PDF

In principle, electron cryo-tomography (cryo-ET) of thin portions of cells provides high-resolution images of the three-dimensional spatial arrangement of all members of the proteome. In practice, however, radiation damage creates a tension between recording images at many different tilt angles, but at correspondingly reduced exposure levels, versus limiting the number of tilt angles in order to improve the signal-to-noise ratio (SNR). Either way, it is challenging to read the available information out at the level of atomic structure.

View Article and Find Full Text PDF

Measuring and monitoring the electrical signals transmitted between neurons is key to understanding the communication between neurons that underlies human perception, information processing, and decision-making. While electrode-based electrophysiology has been the gold standard, optical electrophysiology has opened up a new area in the past decade. Voltage-dependent fluorescent reporters enable voltage imaging with high spatial resolution and flexibility to choose recording locations.

View Article and Find Full Text PDF

Understanding how a network of interconnected neurons receives, stores, and processes information in the human brain is one of the outstanding scientific challenges of our time. The ability to reliably detect neuroelectric activities is essential to addressing this challenge. Optical recording using voltage-sensitive fluorescent probes has provided unprecedented flexibility for choosing regions of interest in recording neuronal activities.

View Article and Find Full Text PDF

The secular dynamics of a nonrelativistic charged particle in an electromagnetic wave can be described by the ponderomotive potential. Although ponderomotive electron-laser interactions at relativistic velocities are important for emerging technologies from laser-based particle accelerators to laser-enhanced electron microscopy, the effects of special relativity on the interaction have only been studied theoretically. Here, we use a transmission electron microscope to measure the position-dependent phase shift imparted to a relativistic electron wave function when it traverses a standing laser wave.

View Article and Find Full Text PDF

Naturally occurring fructosamines are of high clinical significance due to their potential use in diabetes mellitus monitoring (quantification of fructosylated hemoglobin, HbA) or for the investigation of their reactivity in consecutive reactions and harmfulness towards the organism. Here we report the specific synthesis of the fructosylated dipeptide L-valyl-L-histidine (Fru-Val-His) and fructosylated L-valine (Fru-Val). Both are basic tools for the development and validation of enzymatic HbA assays.

View Article and Find Full Text PDF

Atom interferometers are powerful tools for both measurements in fundamental physics and inertial sensing applications. Their performance, however, has been limited by the available interrogation time of freely falling atoms in a gravitational field. By suspending the spatially separated atomic wave packets in a lattice formed by the mode of an optical cavity, we realize an interrogation time of 20 seconds.

View Article and Find Full Text PDF

Transmission electron microscopy (TEM) of rapidly frozen biological specimens, or cryo-EM, would benefit from the development of a phase plate for in-focus phase contrast imaging. Several types of phase plates have been investigated, but rapid electrostatic charging of all such devices has hindered these efforts. Here, we demonstrate electron phase manipulation with a high-intensity continuous-wave laser beam, and use it as a phase plate for TEM.

View Article and Find Full Text PDF

Mobile gravimetry is important in metrology, navigation, geodesy, and geophysics. Atomic gravimeters could be among the most accurate mobile gravimeters but are currently constrained by being complex and fragile. Here, we demonstrate a mobile atomic gravimeter, measuring tidal gravity variations in the laboratory and surveying gravity in the field.

View Article and Find Full Text PDF

Atom interferometers require precise control of digital, analog, and radio frequency signals for effective operation. In this paper, we propose and implement a control system for mobile atom interferometers. The system consists of a microcontroller and peripherals to synthesize radio frequency signals and to read or write analog signals.

View Article and Find Full Text PDF