To enhance sustainability and resilience against climate change in infrastructure, a quantitative evaluation of both environmental impact and cost is important within a life cycle framework. Climate change effects can lead performance deterioration in bridge components during their operational phase, highlighting the necessity for a risk-based evaluation process aligned with maintenance strategies. This study employs a two-phase life cycle assessments (LCA) framework.
View Article and Find Full Text PDFTaehan Yongsang Uihakhoe Chi
November 2021
Purpose: Dedicated breast CT is an emerging volumetric X-ray imaging modality for diagnosis that does not require any painful breast compression. To improve the detection rate of weakly enhanced lesions, an adaptive image rescaling (AIR) technique was proposed.
Materials And Methods: Two disks containing five identical holes and five holes of different diameters were scanned using 60/100 kVp to obtain single-energy CT (SECT), dual-energy CT (DECT), and AIR images.
Recent tragedies around the world have shown how accidents in the cable-stayed bridges can wreak havoc on the society. To ensure the safety of the cable-stayed bridges, several studies have estimated the cable tension force using the vibration of cables. Most of these methods for estimating the tension of a cable start with measuring the displacement of the cable.
View Article and Find Full Text PDFThe feasibility of single-exposure dual-energy imaging (DEI) was investigated in pursuit of motion-artifact-free subtraction angiography. To acquire low- and high-energy images simultaneously from a single X-ray exposure, a sandwich-like multilayered detector was fabricated by configuring two phosphor-coupled photodiode array layers in tandem. A simple analytic model describing the signal in DE-reconstructed images was derived.
View Article and Find Full Text PDFRadiat Prot Dosimetry
November 2021
For the purpose of real-time scan-protocol optimisation and patient-specific dose management in cone-beam computed tomography, we introduce a numerical algorithm that estimates the primary dose distributions in reconstructed images. The proposed algorithm is based on the ray-tracing technique and utilises reconstructed voxel data and scanning protocol. The algorithm is validated with the Monte Carlo (MC) and conventional model-based dose reconstruction methods for the simple cylindrical water and anthropomorphic head phantoms.
View Article and Find Full Text PDFMost dental cone-beam computed tomography (CBCT) uses an x-ray beam field covering the maxillomandibular region and the width-truncated detector geometry. The spatial dose distribution in dental CBCT is analyzed in terms of local primary and remote secondary doses by using a list-mode analysis of x-ray interactions obtained from the Monte Carlo simulations. The patient-dose benefit due to the width-truncated detector geometry is also investigated for a wide range of detector offsets.
View Article and Find Full Text PDFPurpose: We present a new framework for theoretical analysis of the noise power spectrum (NPS) of photon-counting x-ray detectors, including simple photon-counting detectors (SPCDs) and spectroscopic x-ray detectors (SXDs), the latter of which use multiple energy thresholds to discriminate photon energies.
Methods: We show that the NPS of SPCDs and SXDs, including spatio-energetic noise correlations, is determined by the joint probability density function (PDF) of deposited photon energies, which describes the probability of recording two photons of two different energies in two different elements following a single-photon interaction. We present an analytic expression for this joint PDF and calculate the presampling and digital NPS of CdTe SPCDs and SXDs.
Purpose: Acquisition of high-quality x-ray images using low patient exposures requires detectors with high detective quantum efficiency (DQE). We describe a novel apodized-aperture pixel (AAP) design that increases high-frequency modulation transfer function (MTF) and DQE values. The AAP design makes a separation of physical sensor elements from image pixels by using very small sensor elements (e.
View Article and Find Full Text PDFGoal: We investigate the signal and noise performance of an x-ray microtomography system that incorporates a complementary metal-oxide-semiconductor flat-panel detector as a projection image receptor.
Methods: Signal and noise performance is analyzed in the Fourier domain using modulation-transfer function (MTF), noise-power spectrum (NPS), and noise-equivalent number of quanta (NEQ) with respect to magnification and different convolution kernels for image reconstruction.
Results: Higher magnification provides lower NPS, and thus, higher NEQ performance in the transaxial planes from microtomography.
Purpose: The overall goal of this study is to restore kilovoltage computed tomography (kV-CT) images which are disfigured by patients' metal prostheses. By generating a hybrid sinogram that is a combination of kV and megavoltage (MV) projection data, the authors suggest a novel metal artifact-reduction (MAR) method that retains the image quality to match that of kV-CT and simultaneously restores the information of metal prostheses lost due to photon starvation.
Methods: CT projection data contain information about attenuation coefficients and the total length of the attenuation.
Purpose: Single-photon-counting (SPC) x-ray imaging has the potential to improve image quality and enable novel energy-dependent imaging methods. Similar to conventional detectors, optimizing image SPC quality will require systems that produce the highest possible detective quantum efficiency (DQE). This paper builds on the cascaded-systems analysis (CSA) framework to develop a comprehensive description of the DQE of SPC detectors that implement adaptive binning.
View Article and Find Full Text PDFA bioassay-guided fractionation and chemical investigation of the MeOH extract from the twigs of Lindera glauca (SIEB. et ZUCC.) BLUME resulted in the isolation and identification of six lignans (1-6) including three new lignan derivatives, named linderuca A (1), B (2), and C (3).
View Article and Find Full Text PDFX-ray computed laminography is widely used in nondestructive testing of relatively flat objects using an oblique scanning configuration for data acquisition. In this work, a new scanning scheme is proposed in conjunction with the compressive-sensing-based image reconstruction for reducing imaging radiation dose and scanning time. We performed a numerical study comparing image qualities acquired by various scanning configurations that are practically implementable: single-arc, double-arc, oblique, and spherical-sinusoidal trajectories.
View Article and Find Full Text PDFIEEE Trans Med Imaging
October 2013
The absorbed energy distribution (AED) in X-ray imaging detectors is an important factor that affects both energy resolution and image quality through the Swank factor and detective quantum efficiency. In the diagnostic energy range (20-140 keV), escape of characteristic photons following photoelectric absorption and Compton scatter photons are primary sources of absorbed-energy dispersion in X-ray detectors. In this paper, we describe the development of an analytic model of the AED in compound X-ray detector materials, based on the cascaded-systems approach, that includes the effects of escape and reabsorption of characteristic and Compton-scatter photons.
View Article and Find Full Text PDFPurpose: Theoretical models of the detective quantum efficiency (DQE) of x-ray detectors are an important step in new detector development by providing an understanding of performance limitations and benchmarks. Previous cascaded-systems analysis (CSA) models accounted for photoelectric interactions only. This paper describes an extension of the CSA approach to incorporate coherent and incoherent interactions, important for low-Z detectors such as silicon and selenium.
View Article and Find Full Text PDFPurpose: Single-photon counting (SPC) x-ray imaging has the potential to improve image quality and enable new advanced energy-dependent methods. The purpose of this study is to extend cascaded-systems analyses (CSA) to the description of image quality and the detective quantum efficiency (DQE) of SPC systems.
Methods: Point-process theory is used to develop a method of propagating the mean signal and Wiener noise-power spectrum through a thresholding stage (required to identify x-ray interaction events).
On the search for anti-cancer compounds from natural Korean medicinal sources, a bioassay-guided fractionation and chemical investigation of the MeOH extract from the rhizomes of Acorus gramineus resulted in the isolation and identification of thirteen phenolic derivatives (1-13) including two new 8-O-4'-neolignans, named surinamensinols A (1) and B (2) and a new phenolic compound, named acoramol (9). The structures of these new compounds were elucidated on the basis of 1D and 2D NMR spectroscopic data analyses as well as circular dichroism (CD) spectroscopy studies. The cytotoxic activities of the isolates (1-13) were evaluated by determining their inhibitory effects on human tumor cell lines.
View Article and Find Full Text PDFPurpose: This study investigates the fundamental signal and noise performance limitations imposed by the stochastic nature of x-ray interactions in selected photoconductor materials, such as Si, a-Se, CdZnTe, HgI(2), PbI(2), PbO, and TlBr, for x-ray spectra typically used in mammography.
Methods: It is shown how Monte Carlo simulations can be combined with a cascaded model to determine the absorbed energy distribution for each combination of photoconductor and x-ray spectrum. The model is used to determine the quantum efficiency, mean energy absorption per interaction, Swank noise factor, secondary quantum noise, and zero-frequency detective quantum efficiency (DQE).
Purpose: Compressed sensing theory has enabled an accurate, low-dose cone-beam computed tomography (CBCT) reconstruction using a minimal number of noisy projections. However, the reconstruction time remains a significant challenge for practical implementation in the clinic. In this work, we propose a novel gradient projection algorithm, based on the Gradient-Projection-Barzilai-Borwein formulation (GP-BB), that handles the total variation (TV)-norm regularization-based least squares problem for the CBCT reconstruction in a highly efficient manner, with speed acceptable for routine use in the clinic.
View Article and Find Full Text PDFPurpose: X-ray digital subtraction angiography (DSA) is widely used for vascular imaging. However, the need to subtract a mask image can result in motion artifacts and compromised image quality. The current interest in energy-resolving photon-counting (EPC) detectors offers the promise of eliminating motion artifacts and other advanced applications using a single exposure.
View Article and Find Full Text PDFAs a part of our ongoing search for bioactive constituents from natural Korean sources, the investigation of rhizomes of Acorus gramineus afforded five new lignans, named ligraminols A-E (1-5), together with seven known ones (6-12). The structures of 1-5 were determined by a combination of 1D and 2D NMR, HRMS, CD, and enzymatic hydrolysis. Compounds 1-12 were tested for their antiproliferative activities toward a panel of human-derived normal and cancer cell lines.
View Article and Find Full Text PDFThe performance of a specialized dual γ-ray imager using both mechanical and electronic collimation was evaluated by Monte Carlo simulation (MCNP5). The dual imager consisted of an active collimator and a planar detector that were made from scintillators. The active collimator served not only as a coded aperture for mechanical collimation but also as a first detector for electronic collimation.
View Article and Find Full Text PDFThe purpose of this work is to demonstrate an ultra-fast reconstruction technique for digital tomosynthesis (DTS) imaging based on the algorithm proposed by Feldkamp, Davis, and Kress (FDK) using standard general-purpose graphics processing unit (GPGPU) programming interface. To this end, the FDK-based DTS algorithm was programmed "in-house" with C language with utilization of 1) GPU and 2) central processing unit (CPU) cards. The GPU card consisted of 480 processing cores (2 x 240 dual chip) with 1,242 MHz processing clock speed and 1,792 MB memory space.
View Article and Find Full Text PDFPurpose: Energy-resolved x-ray imaging has the potential to improve contrast-to-noise ratio by measuring the energy of each interacting photon and applying optimal weighting factors. The success of energy-resolving photon-counting (EPC) detectors relies on the ability of an x-ray detector to accurately measure the energy of each interacting photon. However, the escape of characteristic emissions and Compton scatter degrades spectral information.
View Article and Find Full Text PDF