The applicability of a polyether ether ketone locking compression plate (PEEK LCP) fabricated using FDM (fused deposition modeling)-based 3D printing to treat actual patients was studied. Three different tests-bending, axial compression, and axial torsion-were conducted on tibial non-osteoporotic comminuted diaphyseal fracture samples fixed with the commercial titanium alloy LCP and 3D-printed PEEK LCP. Comparing the outcomes of these tests revealed that the commercial titanium alloy LCP underwent plastic deformation in the bending and axial torsion tests, though the LCP did not fail even when an external force greater than the maximum allowable load of the tibia fixture of the LCP was applied.
View Article and Find Full Text PDFThis study compared sensitivity encoding (SENSE) and compressed sensing sensitivity encoding (CS-SENSE) for phase oversampling distance and assessed its impact on image quality and image acquisition time. The experiment was performed with a large diameter phantom using 16-channel anterior body coils. All imaging data were divided into three groups according to the parallel imaging technique and oversampling distances: groups A (SENSE with phase oversampling distance of 150 mm), B (CS-SENSE with phase oversampling distance of 100 mm), and C (CS-SENSE with phase oversampling distance of 75 mm).
View Article and Find Full Text PDFIn this study, we assessed how image quality depends on the angle of tilt of a flex tilt coil supporting device during an MRI examination. All measurements were performed with an American College of Radiology (ACR) MRI phantom using a flex tilt coil supporting device. All images were analyzed using an automatic assessment method following the ACR MRI accreditation guidance.
View Article and Find Full Text PDFPurpose: To compare the ability of 2-hydroxyglutarate (2HG)-to-lipid and lactate (2HG/[lipid + lactate]) ratio with the ability of 2HG concentration alone to predict the isocitrate dehydrogenase mutation status in patients with glioma.
Materials And Methods: In this retrospective study, consecutive patients with histopathologically proven glioma were enrolled between July 2016 and February 2019. A total of 79 patients were enrolled (mean age, 44 years; 49 men).
Objective: To compare conventional sensitivity encoding (SENSE) to compressed sensing plus SENSE (CS) for high-resolution magnetic resonance imaging (HR-MRI) of intracranial and extracranial arteries.
Materials And Methods: HR-MRI was performed in 14 healthy volunteers. Three-dimensional T1-weighted imaging (T1WI) and proton density-weighted imaging (PD) were acquired using CS or SENSE under the same total acceleration factors (AF)-5.
Background: Incomplete fat suppression induced by magnetic field inhomogeneity is difficult to compensate for with hardware magnetic-field shimming.
Purpose: To evaluate the effectiveness of a silicone device used to obtain homogeneous fat suppression during 3T magnetic resonance imaging (MRI) scans of the foot.
Material And Methods: Thirty-eight healthy volunteers were enrolled and examined twice, before (group A) and after (group B) the application of a silicone device.