Nihon Hoshasen Gijutsu Gakkai Zasshi
October 2024
Purpose: In DRLs 2020, the entrance surface air kerma (Ka,e) was set to 17 mGy/min as the reference dose rate in fluoroscopy. But, Ka,e in fluoroscopy for different regions and Ka,e in exposure was not set. A multicenter survey was conducted to evaluate Ka,e by each area.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
June 2024
Radiation exposure of a practitioner's fingers is a problem in interventional radiology, and radiation protection gloves (protective gloves) can help reduce such exposure. Several types of protective gloves are commercially available from various manufacturers. In the present study, we compared the protective effects and usability of four types of protective gloves.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
May 2022
This study aimed to investigate the feasibility of estimating functional ischemia information from coronary artery computed tomography (CACT) data (i.e., morphological information).
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
July 2021
We conducted a nationwide multicenter survey of various interventional radiology (IVR) procedures. Data were collected from 385 X-ray systems in 126 institutions, including 432 cine programs and 380 digital subtraction angiography (DSA) programs for diagnostic catheterization, percutaneous coronary intervention (PCI), ablation, transcatheter aortic valve implantation (TAVI), neurologic IVR, thorax IVR, abdominal IVR, and endovascular therapy (EVT). Fluoroscopic and cine dose rates were 10.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
July 2021
The purpose of this study was to educate operators regarding cardiac catheterization using radiation protection slides prepared for this study and to consider whether or not this radiation protection education contributes to reducing the exposure of the operator's ocular lens. Thermoluminescent dosimeter (TLD) was installed at the outside left, inside left, outside right, and inside right of the X-ray protective eyewear of the operators performing the cardiac catheterization. The exposure dose rate before and after radiation protection education for 3 operators performing cardiac catheterization was compared.
View Article and Find Full Text PDFFractional flow reserve (FFR) is used to evaluate the need for percutaneous coronary intervention (PCI) in cases of moderate stenosis of the coronary artery. Recently, diagnostic imaging support with computational fluid dynamics (CFD) analysis has been garnering attention. This study defines the relationship between FFR conducted for cardiac catheterization and CFD analyses conducted using coronary computed tomography (CT) for moderate stenosis, in addition to considering whether wall pressure (WP) and wall shear stress (WSS) can be used to evaluate ischemia.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
September 2020
It is important to optimize the exposure dose when conducting interventional radiology, but optimization is difficult for medical centers to achieve independently. In 2005, we administered a questionnaire on the measurement of dose rates and awareness of exposure reduction when performing percutaneous coronary intervention. Ten years later, we conducted a follow-up survey of the same 31 centers to determine the current situation and identify trends.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
September 2020
We conducted a nationwide survey of multiple institutions and collected data of various interventional procedures in the field of cardiology. Included in the analysis were 126 institutions, 381 X-ray systems, and 805 protocols. The dose values were compared with the Japanese diagnostic reference levels (DRLs) 2015.
View Article and Find Full Text PDFJ Appl Clin Med Phys
December 2019
In coronary angiography (CAG) and percutaneous coronary intervention (PCI), it is important for radiological technologists to optimize the balance between radiation dose and image quality for physicians to be able to perform CAG and PCI most effectively. Evaluation of image processing is necessary to ensure that technologists can optimally adjust image quality for clinical use to the extent that physicians require. However, few phantoms are available for evaluating fluoroscopic image processing, and this makes it necessary to adjust image quality in clinical settings while utilizing the image processing according to the manufacturer's recommendations.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
September 2019
Purpose: We conducted a multicenter study to investigate the current status of difference between the actual values at the patient entrance reference point (PERP) and display air kerma.
Methods: We exposure dose and fluoroscopy dose were measured by 32 apparatuses at 32 member institutions of the Japanese Society of Circulation Imaging Technology (CITEC) under unified conditions, and the actual measured values and display air kerma were compared. We entrance doses during fluoroscopy and imaging were measured at the PERP, with focus detector distance (FDD) 110 cm, a copper plate of 3.
The quality of the present day fluoroscopic images is sufficiently high for use as exposure images depending on the environment where the fluoroscopic images are recorded. In some facilities which use fluoroscopic images as exposure images they are recorded with a radiological x-ray diagnostic device equipped with a fluoroscopic storage function. There are, however, cases where fluoroscopic images cannot be used as exposure images because the quality of the fluoroscopic image cannot be assured in the environment where the fluoroscopic images are recorded.
View Article and Find Full Text PDFIn recent years, reports have been made that predict the state of aneurysm by performing computational fluid dynamics (CFD) analysis using cerebral aneurysm blood flow analysis software. However, analysis results are not constant and there are various opinions, and it is conceivable that the image quality and analysis conditions of medical images used for CFD analysis are not standardized. In this study, CFD analysis of cerebral aneurysm phantom was performed, and image quality and analysis conditions were standardized.
View Article and Find Full Text PDFWe developed a dynamic phantom for use in routine checks. This phantom can be used to physically evaluate image lag that occurs in dynamic images. It has a unique measurement method.
View Article and Find Full Text PDFThis study aimed to evaluate the effect of a metal artifact reduction (MAR) algorithm using 1D linear interpolation on cone-beam CT (CBCT). We performed phantom and clinical qualitative studies with and without MAR application using 1D linear interpolation. In the phantom study, the standard deviation (SD) was estimated from the images obtained from the water phantom in which a metal coil was placed at the center, and observed the changes in the SDs before and after MAR application.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
October 2014
Following recent rapid advances in devices and treatment technology, indications for percutaneous peripheral intervention (PPI) have been expanded to include complex lesions (long-segment lesions, completely obstructed chronic lesions, etc.) and even lesions of the superficial femoral artery and arteries distal to the popliteal artery. However, when PPI is used for treatment of complete obstruction, treatment can take a long time or its outcome can be less satisfactory for reasons such as difficulty in assessing the vascular distribution/arrangement or the direction of calcification in the obstructed area or excessively long lesions.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
June 2014
The hamate bone, one of the carpal (wrist) bones, has a large uncinate process protruding from the palm side. In sports such as golf and tennis, the hamate bone can break if is subjected to a high external force, such as from the handle of a racquet or club. At our hospital we take X-ray images of the hamate bone from two directions: an axial image through the carpal tunnel and an image at the base of the hamate hook (conventional method).
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
October 2013
The reproducibility of lateral radiography of the knee joint in the lateral position is low because patient positioning can be easily affected by passive rotation of the knee joint. We calculated the correction angle of the femoral external rotation and the lower leg elevation and developed our own auxiliary tool for obtaining a lateral view image. We were able to obtain, in a single attempt, an image with misalignment of the condyle limited to less than 7 mm.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
April 2013
We noted that breast-like artifacts occur in photo-stimulable phosphor plates (PSPs) used for long periods in digital mammography systems. This prompted us to investigate the effects on mammography diagnoses of these artifacts. Our study took the form of a comparison between the images generated by a long-term use PSP (four years use) and a short-term use PSP.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
August 2010
How the maintenance checks of the medical treatment system, including start of work check and the ending check, was effective for preventive maintenance and the safety improvement was verified. In this research, date on the failure of devices in multiple facilities was collected, and the data of the trouble repair record was analyzed by the technique of reliability engineering. An analysis of data on the system (8 general systems, 6 Angio systems, 11 CT systems, 8 MRI systems, 8 RI systems, and the radiation therapy system 9) used in eight hospitals was performed.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
July 2010
A catheterization study and treatment of coronary arteriopathy are performed by investigating the coronary artery from different angles to find the region to be treated. In doing so, our system always started from the initial value of the loading factor, using this only for the first time, and the system started from the last loading factor the second time and later, at all angles. Therefore, depending on the angle, the loading factor at the start of fluoroscopy sometimes became unstable, and it took time to stabilize.
View Article and Find Full Text PDFA global quantitative analysis of post-translational modifications (PTMs) of distinct proteins was executed at the proteomic level using two-dimensional fluorescence differential gel electrophoresis. We evaluated the effects of 66 chemical compounds, including 15 genotoxic carcinogens, 28 non-genotoxic carcinogens, and 23 non-carcinogens, in the male F344 rat liver in a 28-day repeated dose study. In the master gel of rat liver protein, we identified 728 spots by hybrid quadrupole time-of-flight mass spectrometry.
View Article and Find Full Text PDFCytochrome P450 isoforms from male rat liver microsomes were comprehensively identified using nano liquid chromatography tandem mass spectrometry (nanoLC-MS/MS). The enrichment of P450, an endomembrane-anchored heme protein, was achieved by solubility-based protein fractionation, and greatly improved the total number of identified P450 isoforms. LC-MS/MS analysis of fractions resulted in the identification of total 36 P450 isoforms.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
June 2007
The new type of coronary angiography(CAG)that uses 40 mm volumetric computed tomography(VCT)has great potential for cardiac disease. However, it is still necessary to be cognizant of exposure dose. We measured doses of CAG by both VCT and cardiovascular X-ray using a body phantom within 170 glass dosimeters.
View Article and Find Full Text PDF