Color-coded circulation is a display method that generates dynamic color-coded images based on the time of arrival of contrast agents using parametric imaging to create video displays. By cyclically displaying information in color according to the arrival time of the contrast agent at each pixel, anatomical blood vessel paths and blood flow information can be simultaneously visualized. Three-dimensional (3D) helical stents increase wall shear stress due to swirling flow and prevent intimal hyperplasia.
View Article and Find Full Text PDFPurpose: To evaluate improvement in local vascular perfusion of the lower limbs on intravoxel incoherent motion (IVIM) imaging after endovascular therapy (EVT).
Materials And Methods: IVIM imaging was performed on 20 lower limbs of 16 patients with lower extremity arterial diseases before and after EVT. To estimate IVIM, diffusion-weighted lower-limb axial images (number of slices = 25 and slice thickness = 3.
A 43-year-old woman, with a history of uterine fibroids and multiple myomectomy, presented with acute lower abdominal pain. Computed tomography revealed multiple tumors, including a high-density mass in the left lower abdomen indicative of a parasitic leiomyoma undergoing red degeneration. This uncommon condition is due to acute occlusion, often caused by peripheral venous thrombosis at the fibroid edge.
View Article and Find Full Text PDFThe assessment of stent lumen patency via non-contrast-enhanced 2-dimensional time-of-flight magnetic resonance angiography (2D TOF MRA) is complex due to stent-related artifacts. However, an imaging technique using the phase-contrast method, which can reduce susceptibility to artifact, is available. Herein, we report the use of 3-dimensional velocity vector image obtained via 4-dimensional flow magnetic resonance imaging (4D flow MRI) for in-stent flow visualization after stent development in the right superficial femoral artery.
View Article and Find Full Text PDFIntravoxel incoherent motion imaging has its improvement-evaluating ability in lower limb perfusion after endovascular therapy in individuals with lower extremity arterial disease. Here, we present a 70-year-old man with intermittent claudication of the left lower limb, whose microperfusion on intravoxel incoherent motion imaging improved after endovascular therapy. The patient underwent intravoxel incoherent motion imaging of the lower extremities pre- and postendovascular therapy.
View Article and Find Full Text PDFPulmonary actinomycosis is a rare disease frequently misdiagnosed as primary lung cancer. Herein, we presented pulmonary actinomycosis mimicking pulmonary cancer on fluorine-18 fluorodeoxyglucose (F-18-FDG) PET-CT.
View Article and Find Full Text PDFPurpose: To evaluate the utility of future liver remnant plasma clearance rate of indocyanine green (ICGK-F) for predicting post-hepatectomy liver failure (PHLF) compared with percentage future liver remnant volume-to-total liver volume ratio (%FLR) after portal vein embolization (PVE).
Materials And Methods: PVE procedures in 20 patients (15 patients underwent PVE with absolute ethanol; 5 patients with gelatin particles) from 2010 to 2017 were analyzed. %FLR = future liver remnant volume (ml)/[total liver volume (ml) - tumor volume (ml)] × 100; ICGK-F = plasma clearance rate of indocyanine green (ICGK) × %FLR/100 were calculated before and after PVE.
Background: The apparent diffusion coefficient (ADC) value is known to be an indicator of tumor activity. The ADC value of high-grade clear-cell renal cell carcinoma (RCC) is significantly lower than that of low-grade clear-cell RCC.
Purpose: To investigate the utility of ADC values of clear-cell RCC by comparing ADC values between groups with T1a RCC (tumor size ≤ 4 cm) without metastasis and the group with metastasis.