Publications by authors named "Hironori Ohba"

Utilizing microlasers and microwaves, our study examined the impact of microwaves on the expansion of air plasma. We applied microwaves to the air plasma generated by a microlaser, visualized its growth using a phone camera, and recorded plasma emissions using a high-resolution spectrometer. Software tools were then used to analyze these emissions for temperature changes and electron density.

View Article and Find Full Text PDF

This study explores the potential of utilizing microwaves to sustain the expansion of transient laser ablation plasma of Zr target. By application of microwaves on the plasma, we observe a significant enhancement with a two to three order of magnitude increase in the plasma emission intensity, and 18 times increase in the plasma's spatial volume. We investigate the temperature change of the plasma and observe that it decreases from 10,000 K to approximately 3000 K.

View Article and Find Full Text PDF

We report on the analysis of pure gadolinium oxide (GdO) and its detection when mixed in surrogate nuclear debris using microwave-enhanced fiber-coupled micro-laser-induced breakdown spectroscopy (MWE-FC-MLIBS). The target application is remote analysis of nuclear debris containing uranium (U) inside the Fukushima Daiichi Nuclear Power Station. The surrogate nuclear debris used in this study contained gadolinium (Gd), cerium (Ce), zirconium (Zr), and iron (Fe).

View Article and Find Full Text PDF

In this study, we developed a simple and one-step Pd separation technique based on photoreduction with Xe lamp irradiation for the determination of Pd in highly radioactive samples. A simulated high-level radioactive liquid wastes (HLLW) solution, consisting of 14 major elements in a 3 mol L HNO solution, was used to evaluate the separation performance. The Pd precipitate was formed by Xe lamp irradiation, and recovered by centrifugation.

View Article and Find Full Text PDF

Laser-induced breakdown spectroscopy (LIBS) combined with liquid jets was applied to the detection of trace sodium (Na) in aqueous solutions. The sensitivities of two types of liquid jets were compared: a liquid cylindrical jet with a diameter of 500 µm and a liquid sheet jet with a thickness of 20 µm. Compared with the cylindrical jet, the liquid sheet jet effectively reduced the splash from the laser-irradiated surface and produced long-lived luminous plasma.

View Article and Find Full Text PDF

We measured X-ray absorption fine structure (XAFS) and Raman spectra of isopolymolybdates(VI) in highly concentrated HNO solution (0.15 - 4.0 M), which change their geometries depending on the acid concentration, and performed the simultaneous resolution of the XAFS and Raman data using a multivariate curve resolution by alternating least-squares (MCR-ALS) analysis.

View Article and Find Full Text PDF

Determination of radiopalladium Pd is required to ensure radiation safety of the Pd extracted from spent nuclear fuel for recycling or disposal. We employed nanosecond laser ablation inductively coupled plasma quadrupole mass spectrometry (ns-LA-ICP-QMS) to simplify the analytical procedure of Pd. Pd was separated through a selective Pd precipitation reaction induced by pulsed laser irradiation that reduces Pd(II) ions to metal Pd(0).

View Article and Find Full Text PDF

Safety evaluation of a radioactive waste repository requires credible activity estimates confirmed by actual measurements. A long-lived radionuclide, Pd, which can be found in radioactive wastes, is one of the difficult-to-measure nuclides and results in a deficit in experimentally determined contents. In this study, a precipitation-based separation method has been developed for the determination of Pd with inductively coupled plasma mass spectrometry.

View Article and Find Full Text PDF

For aqueous-solution-based elemental analysis, we used a thin liquid sheet (μm-scale thickness) in laser-induced breakdown spectroscopy with nanosecond laser pulses. Laser-induced plasma is emitted by focusing a pulsed Nd:YAG laser (1064 nm) on a 5- to 80-μm-thick liquid sheet in air. To optimize the conditions for detecting elements, we studied how the signal-to-background ratio (SBR) for Hα Balmer and Na-neutral emission lines depends on the liquid-sheet thickness.

View Article and Find Full Text PDF

Oxygen isotopic selectivity on infrared multiphoton dissociation of 2,3-dihydropyran has been studied by the examination of the effects of excitation frequency, laser fluence, and gas pressure on the dissociation probability of 2,3-dihydropyran and isotopic composition of products. Oxygen-18 was enriched in a dissociation product: 2-propenal. The enrichment factor of 18O and the dissociation probability were measured at a laser frequency between 1033.

View Article and Find Full Text PDF