Publications by authors named "Hiromi Takiguchi"

A stable two-phase sheath flow using tetrahydrofuran (THF) for an inner flow and water for an outer flow was formed in a glass capillary, and worked as a stable liquid-core/liquid-cladding optical waveguide (THF/water LLW). Although THF and water were miscible with any ratio, the length of the stable THF/water LLW at 0.9 - 2.

View Article and Find Full Text PDF

Surface plasmon field-enhanced fluorescence spectroscopy (SPFS) is a promising methodology for point-of-care (POC) testing. The SPFS devices that have been reported are equipped with an angle rotating stage to adjust the surface plasmon resonance (SPR) angle. In a clinical setting, however, the SPR angle determination is a tedious and time-consuming process.

View Article and Find Full Text PDF

Surface plasmon field-enhanced fluorescence spectroscopy (SPFS) combines enhanced field platform and fluorescence detection. Its advantages are the strong intensity of the electromagnetic field and the high signal/noise (S/N) ratio due to the localized evanescent field at the water/metal interface. However, the energy transfer from the fluorophore to the metal surface diminishes the fluorescence intensity, and this reduces the sensitivity.

View Article and Find Full Text PDF

A novel spectrophotometric flow injection method for determination of silver(I) in a strongly acidic solution containing concentrated copper(II) was developed using a coloring ligand, 4-(3,5-dibromo-2-pyridylazo)-N-ethyl-N-(3-sulfopropyl)aniline (3,5-diBr-PAESA). The method was first investigated by batch method. The interference from copper(II) chelate could be eliminated by the masking effect of EDTA.

View Article and Find Full Text PDF

Surface plasmon resonance (SPR), which provides real-time, in situ analysis of dynamic surface events, is a valuable tool for studying interactions between biomolecules. In the clinical diagnosis of tumor markers in human blood, SPR is applied to detect the formation of a sandwich-type immune complex composed of a primary antibody immobilized on a sensor surface, the tumor marker, and a secondary antibody. However, the SPR signal is quite low due to the minute amounts (ng-pg/mL) of most tumor markers in blood.

View Article and Find Full Text PDF

A sensitive and fast-responsive evanescent wave absorption sensor has been constructed for pH measurements in highly acidic ranges. This sensor is based on a pH-dependent color change of protoporphyrin IX (PPIX). For the sensitive detection, a visible attenuated total reflection spectrometer with a slab optical waveguide (SOWG) was laboratory-made, and the guiding layer surface was modified with a PPIX-immobilized acrylamide-based thin membrane.

View Article and Find Full Text PDF

A flow injection analysis system was built with a liquid core waveguide spectrophotometric detector using an 80 cm Teflon AF-1600 capillary tube (2,2-bistrifluoromethyl-4,5-difluoro-1,3-dioxole/tetrafluoroethylene). The system was applied to determine nitrite ion in river water samples. The lower limit of detection for nitrite was 2.

View Article and Find Full Text PDF

The formation conditions and characteristics of a liquid/liquid optical waveguide (LLW) were studied using a two-phase sheath flow, where the inner organic phase flow acted as the core and the outer aqueous flow acted as the clad. In immiscible solvent systems, i.e.

View Article and Find Full Text PDF

A liquid/liquid optical waveguide was constructed using a sheath flow. Since the refractive index of an organic solvent is generally higher than that of water (nD = 1.33), light introduced into the inner organic flow should proceed with total multi-reflection within the inner flow, so that the inner part of the sheath flow acts as the core of an optical waveguide.

View Article and Find Full Text PDF