Hypoxic training enhances endurance sports tolerance. However, individual responses vary due to physiological differences. This study investigated the relationship between genetic factors and exercise tolerance in hypoxic conditions.
View Article and Find Full Text PDFObjective: To determine the effects of exercise on trunk performance and balance in patients with spinal cord injury (SCI).
Methods: We searched the databases MEDLINE, Cochrane Library, EMBASE, Physiotherapy Evidence Database, Web of Science, PsycINFO, and CINAHL from inception to June 2020. Our search targeted studies such as randomized or non-randomized controlled trials and randomized crossover trials that evaluated the effects of exercise on trunk performance and balance in patients with SCI.
A simple method for determining the anaerobic threshold in patients with heart failure (HF) is needed. This prospective clinical trial (LacS-001) aimed to investigate the safety of a sweat lactate-monitoring sensor and the correlation between lactate threshold in sweat (sLT) and ventilatory threshold (VT). To this end, we recruited 50 patients with HF and New York Heart Association functional classification I-II (mean age: 63.
View Article and Find Full Text PDFSince assessing aerobic capacity is key to enhancing swimming performance, a simple and widely applicable technology should be developed. Therefore, we aimed to noninvasively visualize real-time changes in sweat lactate (sLA) levels during swimming and investigate the relationship between lactate thresholds in sweat (sLT) and blood (bLT). This prospective study included 24 university swimmers (age: 20.
View Article and Find Full Text PDFObjective: To optimize workplace health promotion, a simple method for quantifying allostatic load response is needed. This study examines the feasibility of optimizing objective anxiety and presenteeism monitoring using daily smartwatch-measured ultra-short heart rate variability (HRV).
Methods: Office workers without diagnosed disease prospectively performed 30 s HRV self-measurement each morning for two months and responded to the State-Trait Anxiety Inventory (STAI) and Work Limitation Questionnaire (WLQ).
Background: Local alternating heat and cold stimulation as an alternative to contrast bath may cause intermittent vasoconstriction and vasodilation, inducing a vascular pumping effect and consequently promoting increased tissue blood flow and oxygenation. This study aimed to examine the effects of local alternating heat and cold stimulation, using a wearable thermal device, on the hemodynamics of fatigued muscle tissue and autonomic nervous activity.
Methods: Twenty healthy individuals experienced fatigue in the periarticular muscles of the shoulder joint due to a typing task.
Background: Deterioration of physical function in middle-aged adults is a significant challenge that can lead to increased risk of future falls. However, a screening method for the functional decline in middle-aged adults has not been established.
Research Question: To evaluate the relationship between biomechanical parameters assessed by the timed up and go test (TUG) and locomotive syndrome (LS) in middle-aged adults.
We aimed to investigate the reliability and validity of sweat lactate threshold (sLT) measurement based on the real-time monitoring of the transition in sweat lactate levels (sLA) under hypoxic exercise. In this cross-sectional study, 20 healthy participants who underwent exercise tests using respiratory gas analysis under hypoxia (fraction of inspired oxygen [FiO], 15.4 ± 0.
View Article and Find Full Text PDFA simple, non-invasive algorithm for maximal lactate steady state (MLSS) assessment has not been developed. We examined whether MLSS can be estimated from the sweat lactate threshold (sLT) using a novel sweat lactate sensor for healthy adults, with consideration of their exercise habits. Fifteen adults representing diverse fitness levels were recruited.
View Article and Find Full Text PDFThe relationship between the onset of sweating (OS) and sweat lactate threshold (sLT) assessed using a novel sweat lactate sensor remains unclear. We aimed to investigate the implications of the OS on the sLT. Forty healthy men performed an incremental cycling test.
View Article and Find Full Text PDFA novel exercise modality combined with electrical muscle stimulation (EMS) has been reported to increase cardiovascular and metabolic responses, such as blood lactate concentration. We aimed to examine the effect of constant load pedaling exercise, combined with EMS, by non-invasively and continuously measuring sweat lactate levels. A total of 22 healthy young men (20.
View Article and Find Full Text PDFEpidermal wearable sweat biomarker sensing technologies are likely affected by sweat rate because of the dilution effect and limited measurement methods. However, there is a dearth of reports on the local sweat rate (LSR) monitored in real-time during exercise. This explorative study investigated the feasibility of real-time LSR monitoring and clarified LSR kinetics on the forehead and upper arm during constant-load exercise using a perspiration meter with an airflow compensation system.
View Article and Find Full Text PDFBackground: Plantar pressure assessment is commonly performed to identify pathognomonic gait characteristics and evaluate therapeutics against them in people with various foot disorders. Little is known about the reliability and validity of this assessment in people with hallux valgus (HV) per foot region.
Research Question: This study aimed to assess the reliability and validity of the in-shoe plantar pressure measurement method during gait in people with HV and the required number of footsteps, as an intra-subject sample size, to ensure a reliable and valid use of this method.
Background: A small, wearable thermo device that uses Peltier elements for programmed heat and cold stimulation has been developed recently and is expected to be applied in conventional contrast bath therapy. This study was aimed to examine improvements in trapezius muscle hardness and subjective symptoms resulting from alternating heat and cold stimulation, with different rates of cooling.
Methods: This cross-over study included four conditions.
It is useful to investigate various physiological responses induced by fatigue in athletes. Moreover, wearable noninvasive sensors, including sweat sensors, are compatible with fatigue evaluation because of their ease of use, and ability to measure repeatedly and continual data. This cross-sectional study aimed to clarify how sweat lactate elimination curves obtained during constant workload exercise changed following fatigue.
View Article and Find Full Text PDFBackground: Technological innovations have allowed the use of miniature apparatus that can easily control and program heat and cold stimulations using Peltier elements. The wearable thermo-device has a potential to be applied to conventional contrast bath therapy. This study aimed to examine the effects of alternating heat and cold stimulation (HC) using a wearable thermo-device on subjective and objective improvement of shoulder stiffness.
View Article and Find Full Text PDFParticulate generation occurs during exercise-induced exhalation, and research on this topic is scarce. Moreover, infection-control measures are inadequately implemented to avoid particulate generation. A laminar airflow ventilation system (LFVS) was developed to remove respiratory droplets released during treadmill exercise.
View Article and Find Full Text PDFThe aim of this study was to investigate whether body weight-supported treadmill training with voluntary-driven exoskeleton body weight-supported treadmill training (VDE-BWSTT) improves the quality of life (QOL) of persons with chronic spinal cord injury (SCI). Nineteen individuals with chronic SCI with walking limitation underwent a total of 20 sessions of VDE-BWSTT using the hybrid assistant limb. The QOL was measured using the Short Form-36v2 (SF-36v2) questionnaire at preintervention and postintervention.
View Article and Find Full Text PDFBody weight-supported treadmill training with the voluntary driven exoskeleton (VDE-BWSTT) has been shown to improve the gait function of patients with chronic spinal cord injury. However, little is known whether VDE-BWSTT can effectively improve the trunk function of patients with chronic spinal cord injury. In this open-label, single-arm study, nine patients with chronic spinal cord injury at the cervical or thoracic level (six males and three females, aged 37.
View Article and Find Full Text PDFProlonged computer work and smartphone use can cause stiffness of the neck and shoulder muscles, including the trapezius muscle. Hence, muscle hardness quantification is clinically beneficial. The present study aimed to examine the reliability of trapezius muscle hardness measurement using a portable muscle hardness meter and ultrasound strain elastography.
View Article and Find Full Text PDFStudy Design: A non-randomized open-label single-arm clinical trial.
Objectives: To analyze the effect of body weight supported treadmill training (BWSTT) with the voluntary driven exoskeleton (VDE) in persons with differing levels and completeness of spinal cord injury (SCI) and differing walking abilities.
Setting: Keio University Hospital, Tokyo, Japan.
Possible effects of Chern-Simons (CS) gravity on a quantum interferometer turn out to be dependent on the latitude and direction of the interferometer on Earth in orbital motion around the Sun. Daily and seasonal variations in phase shifts are predicted with an estimate of the size of the effects, wherefore neutron interferometry with ~5 m arm length and ~10(-4) phase measurement accuracy would place a bound on a CS parameter comparable to the Gravity Probe B satellite.
View Article and Find Full Text PDF