This study investigates a novel microfluidic mixing technique that uses the resonant oscillation of coalescent droplets. During the vertical contact-separation process, solutes are initially separated as a result of the combined effects of diffusion and gravity. We show that the application of alternating current (AC) voltage to microelectrodes below the droplets causes a resonant oscillation, which enhances the even distribution of the solute.