Patient respiration is characterized by respiratory parameters, such as cycle, amplitude, and baseline drift. In treatment planning using four-dimensional computed tomography (4DCT) images, the target dose may be affected by variations in image reconstruction techniques and respiratory parameters. This study aimed to optimize 4DCT image reconstruction techniques for the treatment planning of lung stereotactic body radiotherapy (SBRT) based on respiratory parameters using respiratory motion phantom.
View Article and Find Full Text PDFBackground: We devised a method that combines the 3D-Dixon-gradientecho (GRE) method with an improved motion-sensitized driven-equilibrium (iMSDE) to suppress blood flow signals.
Purpose: The purpose of this study was to evaluate the effectiveness of the new method we developed plaque imaging method (3D-Dixon-GRE with the iMSDE method).
Study Type: Retrospective cohort.
In magnetic resonance imaging (MRI), it is necessary to reduce image distortion as much as possible because it suppresses the increase in the planning target volume. This study investigated the relationship between imaging parameters and image distortion when using G-frames. The images were obtained using a 1.
View Article and Find Full Text PDFThis study aimed to investigate the effect of using slice partial Fourier (SPF), phase partial Fourier (PPF), and radial scan (Elliptical scanning) methods on image quality. Changes in signal-to-noise ratio (SNR), effective slice thickness, and in-plane resolution were measured in 3D-gradient echo when SPF, PPF, and radial scan were used. Effective slice thickness increased and SNR increased when SPF was used; in-plane resolution decreased and SNR decreased when PPF was used; effective slice thickness did not change, in-plane resolution decreased, and SNR increased when the radial scan method was used.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
July 2023
Purpose: To validate the point-A dose and dose distribution of metal and resin applicators in comparison with those of TG-43U1.
Methods: The metal and resin applicators consisting of tandem and ovoid were modeled by the egs_brachy. The doses to point A and dose distributions considering each applicator were calculated and compared to those of TG-43U1.
This paper proposes a new concept of phantom development, along with the utilization of new materials that can reproduce lung morphology and density. A lung substitute phantom using microspheres was fabricated; then, its dosimetric utility in radiotherapy was investigated, during which the density was adjusted to closely resemble the morphology of the actual human lung. Microspheres were used to reproduce alveoli, which are the main components of the lung.
View Article and Find Full Text PDFIn this study, we developed a mouthpiece-type gel dosimeter to prevent the oral mucositis caused by the perturbation effect of dental alloys in the radiotherapy of the head and neck regions and to enable in vivo dosimetry. Understanding the dose distribution in the oral cavity during radiotherapy helps identify the possible site for oral mucositis during treatment. Here agarose, which has a higher melting point than gelatin, was added as a coagulant to stabilize the shape of the dosimeter.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
May 2022
Purpose: The incident electron energy spectrum was determined by an estimation formula based on the Lévy distribution in order to calculate the PDD and OAR that is consistent with the measurement.
Methods: EGSnrc was used to calculate PDD and OAR at nominal energies of 4, 6, 9, 12, and 15 MeV. The parameters for determining the incident electron energy spectrum were adjusted to be a reasonable value in the error between the measured and the calculated values.
This study aimed to quantitatively clarify the baseline drift for each respiratory cycle in two respiratory-gating methods using the intra-beam respiratory motion data of lung cancer patients. The residual motion and dose distribution were calculated based on intra-beam respiratory motion data with the baseline drift. To quantify the baseline drift $\Delta$ during irradiation, it was defined as the inclination between the detected expiration point and the expiration point in the next cycle in the anterior-posterior (AP), cranial-caudal (CC) and left-right (LR) directions obtained using an in-house programme.
View Article and Find Full Text PDFReal-time tumor tracking radiotherapy (RTRT) systems typically use fiducial markers implanted near the tumor to track the target using X-ray fluoroscopy. Template pattern matching, used in tracking, is often used to automatically localize the fiducial markers. In radiotherapy of the liver, the thickness of the body that can recognize the fiducial markers must be clinically assessed.
View Article and Find Full Text PDFTemperature corrections are necessary to account for the varying mass of air in the cavity volume of a vented ionization chamber. The temporal response resulting from temperature changes in a cylindrical and/or Farmer-type ionization chamber, which is the standard dosimeter, has been thoroughly discussed by some researchers. The purpose of this study was to characterise and analyse the dependence of the cavity air temperature of the parallel-plate-type ionization chamber on changes in the ambient temperature.
View Article and Find Full Text PDFIn this study, we propose a methodology for temperature determination of the temperature and pressure correction factor, PTP, by analyzing the temperature distribution of the modeled ionization chamber taking into account the thermal effect of a water phantom on neighboring materials in the process. Additionally, we present an appropriate temperature-equilibrium time for conducting measurements. The temporal response in the cavity is acquired at 20-s intervals using a Farmer ionization chamber and an electrometer.
View Article and Find Full Text PDFAppl Radiat Isot
September 2019
Herein, we investigate the use of agar and gelatin in a polymer gel dosimeter. The polymer gel is enclosed in a vinyl film to obtain a dosimeter of arbitrary shape and maintain the shape at room temperature. The resulting polymer gel dosimeter could preserve its shape across a wide temperature range.
View Article and Find Full Text PDFTangential beam radiotherapy is routinely used for radiation therapy after breast conserving surgery. A tissue-equivalent bolus placed on the irradiated area shifts the depth of the dose distribution; this bolus provides uniform dose distribution to the breast. The gel bolus made by the BANG-Pro(®) polymer gel and in an oxygen non-transmission pack was applicable as a dosimeter to measure dose distribution in near-surface buildup region.
View Article and Find Full Text PDFIn this study, we developed an isocenter verification device for use in proton therapy. Radiation and mechanical isocenters were verified for treatment equipment including room lasers, a digital radiography system and the beam axis of a rotational gantry. The special feature of this device is its ability to correlate the position of the three isocenters in one measurement and thus improve accuracy compared to the conventional method using three separate devices.
View Article and Find Full Text PDFExternal electron radiotherapy is performed using a cone or applicator to collimate the beam. However, because of a trade-off between collimation and scattering/bremsstrahlung X-ray production, applicators generate a small amount of secondary radiation (leakage). We investigate the peripheral dose outside the radiation field of a Varian-type applicator.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
February 2012
It is stated that cardiac MRI imaging can provide accurate estimation of left ventricular (LV) volumes and ejection fraction (EF). The purpose of this study was to evaluate the accuracy of gated myocardial perfusion SPECT for assessment of LV end-diastolic volume (EDV), end-systolic volume (ESV) and EF, using cardiac MRI as the reference methods/(methodology). Gated myocardial perfusion SPECT images were analyzed with two different quantification software, QGS and 4D-MSPECT.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
November 2011
Unlabelled: The purpose of this study was to evaluate the effect of myocardial perfusion imaging that is reconstructed using the ordered subsets-expectation maximization (OS-EM) method with collimator broad correction.
Methods: A cardiac phantom and clinical data (with ten normal patients) were used. These projection data were reconstructed using OS-EM with collimator broad correction (OS-EM(+)), without collimator broad correction (OS-EM(-)), and with filtered back projection (FBP).