Purpose: The application of histotripsy, an emerging noninvasive, non-ionizing, and non-thermal tumor treatment, is currently limited by the inherent limitations of diagnostic ultrasound as the sole targeting modality. This study evaluates the feasibility and accuracy of cone beam computed tomography (CBCT) guidance for histotripsy treatments in an porcine model.
Materials And Methods: Histotripsy treatments were performed in the liver of seven healthy swine under the guidance of a C-arm CBCT system that was calibrated to the robotic arm of the histotripsy system.
Cryo-electron tomography (cryoET) provides sub-nanometer protein structure within the dense cellular environment. Existing sample preparation methods are insufficient at accessing the plasma membrane and its associated proteins. Here, we present a correlative cryo-electron tomography pipeline optimally suited to image large ultra-thin areas of isolated basal and apical plasma membranes.
View Article and Find Full Text PDFPurpose: To evaluate the response of the ureter and renal pelvis to direct targeting by histotripsy guided by cone-beam computed tomography (CT) in a human-scale porcine chronic-survival model.
Materials And Methods: Bilateral ureteral histotripsy treatments were completed on 6 female swine (n = 12). Animals were divided into 2 groups: (a) acute (n = 2 animals, 4 treatments, sacrificed at Day 0) and (b) chronic (n = 4 animals, 8 treatments, sacrificed at Day 7 [n = 2] and Day 28 [n = 2]).
Cryo-electron tomography (cryoET) provides sub-nanometer protein structure within the dense cellular environment. Existing sample preparation methods are insufficient at accessing the plasma membrane and its associated proteins. Here, we present a correlative cryo-electron tomography pipeline optimally suited to image large ultra-thin areas of isolated basal and apical plasma membranes.
View Article and Find Full Text PDFDynamin assembles as a helical polymer at the neck of budding endocytic vesicles, constricting the underlying membrane as it progresses through the GTPase cycle to sever vesicles from the plasma membrane. Although atomic models of the dynamin helical polymer bound to guanosine triphosphate (GTP) analogs define earlier stages of membrane constriction, there are no atomic models of the assembled state post-GTP hydrolysis. Here, we used cryo-EM methods to determine atomic structures of the dynamin helical polymer assembled on lipid tubules, akin to necks of budding endocytic vesicles, in a guanosine diphosphate (GDP)-bound, super-constricted state.
View Article and Find Full Text PDFRadiol Imaging Cancer
March 2024
Purpose To determine if microwave ablation (MWA) of retroperitoneal tumors can safely provide high rates of local tumor control. Materials and Methods This retrospective study included 19 patients (median age, 65 years [range = 46-78 years]; 13 [68.4%] men and six [31.
View Article and Find Full Text PDFBackground Splenic biopsy is rarely performed because of the perceived risk of hemorrhagic complications. Purpose To evaluate the safety of large bore (≥18 gauge) image-guided splenic biopsy. Materials and Methods This retrospective study included consecutive adult patients who underwent US- or CT-guided splenic biopsy between March 2001 and March 2022 at eight academic institutions in the United States.
View Article and Find Full Text PDFTech Vasc Interv Radiol
September 2023
CT navigation (CTN) has recently been developed to combine many of the advantages of conventional CT and CT-fluoroscopic guidance for needle placement. CTN systems display real-time needle position superimposed on a CT dataset. This is accomplished by placing electromagnetic (EM) or optical transmitters/sensors on the patient and needle, combined with fiducials placed within the scan field to superimpose a known needle location onto a CT dataset.
View Article and Find Full Text PDFPurpose: To evaluate the concordance between lung biopsy puncture pathways determined by artificial intelligence (AI) and those determined by expert physicians.
Materials And Methods: An AI algorithm was created to choose optimal lung biopsy pathways based on segmented thoracic anatomy and emphysema in volumetric lung computed tomography (CT) scans combined with rules derived from the medical literature. The algorithm was validated using pathways generated from CT scans of randomly selected patients (n = 48) who had received percutaneous lung biopsies and had noncontrast CT scans of 1.
Purpose: Multidisciplinary conferences (MDCs) are important for clinical care but are unreimbursed and can be time-consuming for radiologists to prepare for and present. The purpose of this single-center, prospective, survey-based study is to measure the per-conference time and total time radiologists devote to MDCs at a single academic medical center. Secondary objectives are to determine the source of radiologist preparation time, and calculate the per conference and overall radiology departmental costs of MDC participation.
View Article and Find Full Text PDFDominant optic atrophy is one of the leading causes of childhood blindness. Around 60-80% of cases are caused by mutations of the gene that encodes optic atrophy protein 1 (OPA1), a protein that has a key role in inner mitochondrial membrane fusion and remodelling of cristae and is crucial for the dynamic organization and regulation of mitochondria. Mutations in OPA1 result in the dysregulation of the GTPase-mediated fusion process of the mitochondrial inner and outer membranes.
View Article and Find Full Text PDFPurpose: To compare the safety and efficacy of histotripsy with cryoablation in a chronic human-scale normal porcine kidney model.
Materials And Methods: Eighteen female domestic swine were divided evenly into histotripsy and cryoablation treatment arms. A planned 2-3 cm diameter treatment was performed under ultrasound (histotripsy) or ultrasound and computed tomography (CT) guidance (cryoablation).
Purpose: To compare electromagnetic navigation (EMN) with computed tomography (CT) fluoroscopy for guiding percutaneous biopsies in the abdomen and pelvis.
Materials And Methods: A retrospective matched-cohort design was used to compare biopsies in the abdomen and pelvis performed with EMN (consecutive cases, n = 50; CT-Navigation; Imactis, Saint-Martin-d'Hères, France) with those performed with CT fluoroscopy (n = 100). Cases were matched 1:2 (EMN:CT fluoroscopy) for target organ and lesion size (±10 mm).
Objective: To compare the acute and chronic safety and treatment effects of non-invasive hepatic histotripsy vs. percutaneous microwave (MW) ablation in a healthy porcine model.
Methods: This was a dual-arm study in which each animal (n = 14) received either a single hepatic microwave (n = 6) or histotripsy (n = 6 single treatment; n = 2 double treatment) under ultrasound guidance.
Purpose: To evaluate the efficacy and safety of microwave (MW) ablation as first-line locoregional therapy (LRT) for bridging patients with hepatocellular carcinoma (HCC) to liver transplant.
Materials And Methods: This retrospective study evaluated 88 patients who received percutaneous MW ablation for 141 tumors as first-line LRT for HCC and who were listed for liver transplantation at a single medical center between 2011 and 2019. The overall survival (OS) rate statuses after liver transplant, waitlist retention, and disease progression were evaluated using the Kaplan-Meier techniques.
Transmembrane β barrel proteins are folded into the outer membrane (OM) of Gram-negative bacteria by the β barrel assembly machinery (BAM) via a poorly understood process that occurs without known external energy sources. Here, we used single-particle cryo-EM to visualize the folding dynamics of a model β barrel protein (EspP) by BAM. We found that BAM binds the highly conserved "β signal" motif of EspP to correctly orient β strands in the OM during folding.
View Article and Find Full Text PDFER network formation depends on membrane fusion by the atlastin (ATL) GTPase. In humans, three paralogs are differentially expressed with divergent N- and C-terminal extensions, but their respective roles remain unknown. This is partly because, unlike Drosophila ATL, the fusion activity of human ATLs has not been reconstituted.
View Article and Find Full Text PDFPurpose: To evaluate utility of advanced CT techniques including HighlY constrained back-projection and dual-energy CT for intra- and post-procedure hepatic microwave ablation zone monitoring.
Methods: 8 hepatic microwave ablations were performed in 4 adult swine (5 min/65 W). Low-dose routine CECT and dual-energy CT images were obtained every 1 min during ablation.
Background: The purpose of this study is to evaluate the safety and intermediate-term efficacy of percutaneous microwave (MW) ablation for the treatment of colorectal liver metastases (CRLM) at a single institution.
Methods: A retrospective review was performed of all CRLM treated with MW ablation from 3/2011 to 7/2020 (102 tumors; 72 procedures; 57 patients). Mean age was 60 years (range, 36-88) and mean tumor size was 1.
Management options for small renal masses include active surveillance, partial nephrectomy, radical nephrectomy, and thermal ablation. For tumors typically ≤3 cm in size, thermal ablation is a good option for those desiring an alternative to surgery or active surveillance, especially in patients who are considered high surgical risk. We favor microwave ablation because of the more rapid heating, higher temperatures that overcome the heat sink effect of vessels, reproducible cell kill, and a highly visible ablation zone formed by water vapor that corresponds well to the zone of necrosis.
View Article and Find Full Text PDF