Publications by authors named "Hilton A Koch"

Background and Objectives: Proximal humerus fractures are the second most frequent site of avascular necrosis (AVN), occurring in up to 16% of cases. The Hertel criteria have been used as a reference for the prediction of humerus head ischemia. However, these are based solely on the use of radiographs, which can make interpretation extremely difficult due to several reasons, such as the overlapping fragments, severity of the injury, and noncompliant acute pain patients.

View Article and Find Full Text PDF

Articular fractures of the distal humerus in adults are challenging fractures requiring adequate surgical exposure for optimum reconstruction. Most commonly, an articular osteotomy of the olecranon is performed, but complications have been reported related to both creating and repairing the articular osteotomy. We describe the use of an extra-articular olecranon osteotomy for approaching articular fractures of the distal humerus.

View Article and Find Full Text PDF

Our objective is to describe the technique of intramedullary (IM) nailing of lateral malleolus in the surgical management of ankle fractures. Fracture reduction is performed either percutaneously with a small pointed reduction clamp in simple oblique fractures or using longitudinal traction and rotation for comminuted fractures, thus reducing complications related to open reduction and internal fixation with a plate. The technique has been shown to be simple and reproducible.

View Article and Find Full Text PDF

The aim of this study was to evaluate the biomechanical role of both a non-locking two-hole small fragment dynamic compression plate with 3.5-mm screws and a 4.5-mm cortical screw with a washer applied to a Schatzker type-I tibial plateau fracture.

View Article and Find Full Text PDF

Objective To describe functional and quality of life results after extended supratracheal laryngectomy. Methods In the period from September 2009 to January 2018, 11 male subjects were submitted to extended supratracheal laryngectomy. Swallowing abilities were assessed through videofluoroscopy and the clinical scale Functional Communication Measures of Swallowing.

View Article and Find Full Text PDF

Purpose: Despite the fact that open reduction and internal fixation with a plate, either non-locked or locked, is the standard of care for managing lateral malleolus fractures, intramedullary (IM) fixation of the fibula has been recently introduced as an alternative, mainly for some potential complicated situations. We hypothesized that almost all patterns of distal fibula fracture can be safely fixed with an IM device, with the potential benefit of providing biomechanical efficiency, but using a soft-tissue friendly implant. Here, we present a multicenter case series based on a proposed algorithm.

View Article and Find Full Text PDF

Purpose: The aim of this study is to compare the biomechanical behavior of three different fixation constructions currently used for buttressing the posteromedial shearing tibial plateau fragment. Our hypothesis is that non-locked implants provide sufficient comparable stability in posteromedial tibial plateau fractures as locked implants.

Methods: Fifteen left synthetic tibiae from a single manufacturing batch were used to create a posteromedial shear tibial plateau fracture.

View Article and Find Full Text PDF

 The aim of the present study was to evaluate the practices and preferences of Brazilian orthopedic surgeons for the treatment of femoral neck fractures in middle-aged patients.  A survey containing 10 images of femoral neck fractures was sent to a group of 100 orthopedic surgeons, all of them members of the Brazilian Society of Orthopedics and Traumatology. The questionnaire asked the treatment option for cases of nondisplaced and displaced fractures of the femoral neck in middle-aged patients, that is, those between 50 and 69 years old.

View Article and Find Full Text PDF

Background: The purpose of this study was to evaluate the role of a non-locking plate applied to the anteromedial surface of the proximal humerus on loads at the implant-bone interface of non-locking and locking lateral plate fixation of proximal humeral fractures with a medial gap.

Methods: Twenty synthetic humeri models were used. In fifteen, the proximal portion of the humerus was osteotomized to create a two-part surgical neck fracture, with a 10-mm medial gap and a 5-mm lateral gap; five models were controls.

View Article and Find Full Text PDF

Background: The biomechanical behavior of Pauwels type III fractures should be taken into consideration when performing internal fixation, since this repair should resist the shear force inherent in the vertical fracture line to the greatest extent possible. Recently, the use of a small fragment plate on the medial face of the femoral neck has been proposed by some authors, with satisfactory initial results. In the current study we analyze the mechanical role a medial plate used as a buttress plate for Pauwels type III femoral neck fractures, comparing the resistance of two fixation configurations using three cannulated screws.

View Article and Find Full Text PDF

Dysplasia epiphysealis hemimelica is a rare osteocartilaginous overgrowth syndrome of bone epiphysis, mostly encountered in the lower limbs of immature skeleton patients. We report a case of proximal humerus presentation in an adult male, with neither articular involvement nor clinical dysfunction. This case highlights the importance of stratification into intra- and extra-articular lesions, as this distinction ultimately influences both symptoms and treatment outcome.

View Article and Find Full Text PDF

Acral metastases in the hand are exceedingly rare. We present the unusual case of a metastatic tumor of the hand of unknown primary site in a 77-year-old man with no known cancer history. The patient presented with pain and swelling in the tip of the left ring finger, which had previously been diagnosed as gout at another clinic.

View Article and Find Full Text PDF

Femoral head fractures occur almost exclusively as a result of a traumatic hip dislocation. Treatment is typically an emergency and includes the reduction of the dislocated hip under anesthesia. As a rule, the earlier the reduction, the better the outcome.

View Article and Find Full Text PDF

Introduction: The use of mini plates as a reduction tool is an elegant technique for temporary stabilization of multifragmentary fractures. For some complex periarticular fractures with severe comminution close to the articular surface, mini plates seem to be a better option than K-wires for provisional as well as definitive fixation, because of the presence of small fragments and proximity to the joint increases the risk of additional fragmentation and articular penetration, respectively.

Case Report: Five cases of complex periarticular fractures of the upper limb are presented.

View Article and Find Full Text PDF

Avulsion fractures of the calcaneal tuberosity represent a rare injury pattern that is caused by a powerful tension force from the Achilles tendon and is usually seen following minor trauma, especially in elderly patients. The objective of this study is to describe a surgical technique using cerclage wiring through cannulated screws in the treatment of extra- and intra-articular avulsion fractures of the calcaneal tuberosity and to present our results in a small patient's cohort. Through a 5.

View Article and Find Full Text PDF

There is a strong relationship between venous thromboembolism and cancer. Patients with tumors have a higher incidence of thromboembolic events in their clinical evolution. The occurrence of such events is considered a negative predictive marker in this group of patients.

View Article and Find Full Text PDF

Objective The primary aim of this study was to survey current practices and preferences behind internal fixation of trochanteric femoral fractures among Brazilian orthopedic surgeons. The secondary aim was to identify the main reason for these preferences. Methods A survey containing 20 images of trochanteric fractures of the femur was presented to a group of 62 orthopedists, all members of the Brazilian Society of Orthopedics and Traumatology (SBOT).

View Article and Find Full Text PDF

Purpose: The aim of our study is to compare the mechanical resistance of two screw configurations in fixating type II Pauwels femoral neck fractures.

Methods: Fifteen synthetic models of femur bones in young adults were divided into three equal groups: intact (G1), models with fixation of a 5.0-mm failure zone created in the posterior cortex of the femoral neck using an L-shaped screw arrangement (G2, n = 5), and models with an identical failure zone fixated using an inverted triangle assembly (G3, n = 5).

View Article and Find Full Text PDF

Objective: To determine the ideal working area for a simple transverse fracture line treated with a bridge plate.

Methods: A 2-D finite element analysis of a hypothetical femur was performed for the quantitative evaluation of a large-fragment titanium alloy locking plate based on the precept of relative stability in a case of a simple transverse diaphyseal fracture. Two simulations (one case of strain and another case of stress distribution) were analyzed in three unique situations according to the von Mises stress theory.

View Article and Find Full Text PDF

Background: The universal accepted strategy for treating high-energy tibial plateau fractures remains a topic of ongoing debate. The challenge for the practicing orthopaedic trauma surgeon is to provide anatomical articular fracture reduction, with successfully managing the complex soft-tissue injury that is commonly present at patient admission. The primary aim of the actual study was to evaluate the results of a staged protocol for the treatment of high-energy bicondylar tibial plateau fractures.

View Article and Find Full Text PDF

To evaluate the mechanical stress and elastic deformation exercised in the thread/shaft transition of Schanz screws in assemblies with different screw anchorage distances in the entrance to the bone cortex, through the distribution and location of tension in the samples. An analysis of 3D finite elements was performed to evaluate the distribution of the equivalent stress (triple stress state) in a Schanz screw fixed bicortically and orthogonally to a tubular bone, using two mounting patterns: (1) thread/shaft transition located 20 mm from the anchorage of the Schanz screws in the entrance to the bone cortex and (2) thread/shaft transition located 3 mm from the anchorage of the Schanz screws in entrance to the bone cortex. The simulations were performed maintaining the same direction of loading and the same distance from the force vector in relation to the center of the hypothetical bone.

View Article and Find Full Text PDF

Background: Open pelvic fractures are rare but usually associated with a high incidence of complications and increased mortality rates. The aim of this study was to retrospectively evaluate all consecutive open pelvic fractures in patients treated at a single Level-1 Trauma Center during a 10-year interval.

Patients And Methods: In a 10-year interval, 30 patients with a diagnosis of open pelvic fracture were admitted at a Level-1 Trauma Center.

View Article and Find Full Text PDF

Objective: : to evaluate the histologic and morphometric characteristics of bone biopsies of the anterior iliac crest of patients of different age groups.

Methods: : we studied 30 bone samples from the iliac crest, using brightfield optical microscopy. We divided the samples by donors' age groups in three groups: Group 1 (n = 10), subjects aged between 25 and 39 years; Group 2 (n = 10), subjects aged between 40 and 64 years; Group 3 (n = 10), individuals aged 65 years and over.

View Article and Find Full Text PDF

Objective: The aim of this study was to evaluate the inter- and intra-observer agreement in the initial diagnosis and classification by means of plain radiographs and CT scans of tibial plateau fractures photographed and sent via WhatsApp Messenger.

Background: The increasing popularity of smartphones has driven the development of technology for data transmission and imaging and generated a growing interest in the use of these devices as diagnostic tools. The emergence of WhatsApp Messenger technology, which is available for various platforms used by smartphones, has led to an improvement in the quality and resolution of images sent and received.

View Article and Find Full Text PDF