Objective: Extracorporeal membrane oxygenation has been shown to be effective in term neonates with severe but reversible lung disease within the context of randomized, controlled trials. Extracorporeal membrane oxygenation now has been open to a wider population of infants in the United Kingdom, and other treatments have become available. The population referred for extracorporeal membrane oxygenation, therefore, has changed.

View Article and Find Full Text PDF

Introduction: The inflammatory response caused by extracorporeal membrane oxygenation (ECMO) is clearly visible within the first 24 h of cannulation. The inflammatory process affects all areas of the lung, even areas previously spared by the primary disease.

Objective: To compare the change in the radiographic signs of inflammatory response to ECMO between poly-methyl pentene and silicon oxygenators.

View Article and Find Full Text PDF

Background: An estimated 350 adults develop severe, but potentially reversible respiratory failure in the UK annually. Current management uses intermittent positive pressure ventilation, but barotrauma, volutrauma and oxygen toxicity can prevent lung recovery. An alternative treatment, extracorporeal membrane oxygenation, uses cardio-pulmonary bypass technology to temporarily provide gas exchange, allowing ventilator settings to be reduced.

View Article and Find Full Text PDF

Objective: To report a single case of oxygenator failure caused by clot embolism originating from the bladder; and to discuss some preventative options.

Case Report: A 2.5 kg neonate with a diagnosis of influenza A received veno-arterial (V-A) extracorporeal membrane oxygenation (ECMO) for cardiorespiratory support.

View Article and Find Full Text PDF

Objective: To review the performance of polymethyl pentene versus silicone oxygenators in terms of efficiency in priming and oxygenation, oxygenator resistance, requirements for coagulation proteins and consumption of blood products, for neonatal extracorporeal membrane oxygenation (ECMO) patients.

Study Design: Forty consecutive neonates were selected retrospectively pre- and post-introduction of the new polymethyl pentene (PMP) oxygenators. They formed two equal groups.

View Article and Find Full Text PDF

The performance of poly-methyl pentene (PMP) oxygenators (Medos Hilite 7000LT) was compared with that of silicone membrane (SM) oxygenators (Medtronic 1-4500-2A) for adult extracorporeal membrane oxygenation (ECMO). Forty consecutive patients were selected retrospectively pre- and post-introduction of PMP oxygenators. They were selected according to the dates they received ECMO and were separated into two equal groups with similar backgrounds.

View Article and Find Full Text PDF

Objective: To investigate the safety and feasibility of using mild hypothermia in neonates receiving extracorporeal membrane oxygenation (ECMO). Study design A prospective, nonrandomized pilot study of 25 neonates referred for ECMO. Whole body cooling was achieved by adjustment of the temperature of the extracorporeal circuit water bath.

View Article and Find Full Text PDF

Severe B. pertussis infection in infants is characterized by severe respiratory failure, pulmonary hypertension, leukocytosis, and death. This retrospective case analysis highlights the course and outcome of severe B.

View Article and Find Full Text PDF

The experience of extracorporeal membrane oxygenation (ECMO) use for severe chickenpox pneumonia was reviewed. Case notes of all patients treated with ECMO for this disease between 1992 and 1997 were reviewed. Of 405 patients referred for ECMO during this period, the diagnosis was chickenpox pneumonia in 14 (3.

View Article and Find Full Text PDF

Silicone oxygenators are the standard devices used for Extracorporeal Life Support (ECLS), but they have some limitations. Microporous polypropylene hollow fiber oxygenators overcome many of these problems but, unfortunately, develop plasma leak. Polymethyl-pentene (PMP) is a novel oxygenator material.

View Article and Find Full Text PDF

Unlabelled: We measured the response of fresh heparinized human blood to recirculation through circuits made of LVA (Portex Industries, Hythe, Kent, UK), SRT (Rehau UK, Langley, Slough, UK) and Tygon S-65-HL (Norton Performance Plastics, Corby, Northants, UK), as control. Circuit construction: 1/2 in. tubing, heat exchanger (Dideco D-720P), Stockert roller pump, just underoccluded, Cincinnati Sub Zero heater, circuit volume of 500 ml.

View Article and Find Full Text PDF