Introduction: The OneTouch Verio Reflect (OTVR) Blood Glucose Meter features a color range indicator and provides on-meter guidance, insights, and encouragement. Diabetes management is enhanced by the OneTouch Reveal (OTR) Mobile App. We sought to provide real-world evidence (RWE) that combining devices improves glycemia.
View Article and Find Full Text PDFBackground: Glucose oxidase (GOx)-based blood glucose monitors (BGMs) are influenced by the partial pressure of oxygen (Po) within the applied sample. Limited in-clinic data exists regarding the quantitative effect of Po in unmanipulated capillary fingertip blood samples across physiologically representative glucose and Po ranges.
Method: Clinical accuracy data were collected as part of a BGM manufacturer's ongoing post-market surveillance program for a commercially available GOx-based BGM test-strip.
Background: The OneTouch Verio Flex® (OTVF) blood glucose (BG) meter features a ColorSure® Range Indicator. Diabetes management is enhanced by connecting the meter to the OneTouch Reveal® (OTR) mobile app. We sought to provide real-world evidence (RWE) that combining both devices improves glycemic control.
View Article and Find Full Text PDFThe OneTouch Verio Reflect (OTVR) meter provides ColorSure Dynamic Range Indicator (DCRI) and Blood Sugar Mentor (BSM) features that are complemented by the OneTouch Reveal (OTR) mobile app. We sought to provide real-world evidence that these products support improved glycemic control. Anonymised glucose and app analytics were extracted from the LifeScan server for 4154 people with type 1 diabetes (PwT1D) and 13,623 people with type 2 diabetes (PwT2D).
View Article and Find Full Text PDFA data set comprising 28 533 oxygen partial pressure (pO) values gathered from nonarterialized fingertip capillary blood samples of a large diabetes population is reported. Data were gathered routinely as part of the ongoing clinical surveillance activities of a blood glucose monitoring (BGM) system manufacturer. Overall, a mean pO level of 75.
View Article and Find Full Text PDFObjective: To demonstrate the clinical value of OneTouch (OT) Verio Flex glucose meter used in combination with a Spanish-language version of the OT Reveal mobile application (app) to support diabetes care and improve glycemic control in an underserved Hispanic population with type 2 diabetes.
Research Design And Methods: Test subjects ( = 81) used the meter and app for 12 weeks, while a randomized control group ( = 39) used their own glucose meters without connection to an app. Thereafter, test subjects continued the same regimen for an additional 12 weeks to determine the durability of effect, and control subjects crossed over to use the new meter and app.
Background: Regulations and industry guidance relating to testing for interference in blood glucose monitoring (BGM) systems continue to focus on in vitro laboratory bench tests. Post-market surveillance (PMS) in a clinical setting allows for BGM accuracy assessments to evaluate the impact of real-world exposure to polypharmacy in people with diabetes. This study evaluated the OneTouch Select Plus® BGM test-strip accuracy with respect to polypharmacy using a clinical registry dataset.
View Article and Find Full Text PDFBackground: On-going manufacturer-led post-market surveillance (PMS), assessing the clinical accuracy of blood glucose monitoring (BGM) systems, is critical to substantiate the performance of such products for people with diabetes.
Materials And Methods: Batches of Verio test-strip product were randomly and routinely selected over the period from launch of an improved-algorithm product to reporting date and sent to 3 clinic sites for clinician-led accuracy assessment. Accuracy is reported as per recently adopted FDA guidance for BGM systems, EN ISO 15197:2015 and MARD/MAD (Mean absolute relative difference/Mean absolute difference).
Background: We examined whether dynamic color range indicator (DCRI) and blood sugar mentor (BSM) features in a new blood glucose meter could improve interpretation of results and encourage patient action.
Methods: One hundred and thirty three people with type 2 (T2D) ( = 73) or type 1 diabetes (T1D) ( = 60) evaluated information first without and then with DCRI or BSM guidance using interactive exercises.
Results: Subjects improved their ability to categorize results into low, in range, or high glycemic ranges by 29% (T2D) and 22% (T1D) (each < .
People with diabetes (PWD) who need to take mealtime insulin to help control their blood sugar often have difficulty correctly calculating their dose due to consideration of many factors such as current blood glucose, carbohydrate consumption, active insulin duration, insulin-to-carb ratio, and insulin sensitivity. The Insulin Mentor, a bolus calculator tool in the OneTouch Reveal diabetes management app, uses an algorithm to automate many of these calculations and contains a link to a food diary to help estimate carbohydrate intake. In the current study, healthcare professionals and PWD from United States and Germany responded favorably to simulations of this calculator tool and compared it positively with other apps on the market.
View Article and Find Full Text PDFThe OneTouch Verio Reflect blood glucose monitor (BGM) has market clearance in several countries based in part on fulfilling the lay user and system accuracy criteria described in ISO15197:2015. However, the Food and Drug Administration (FDA) does not recognize the accuracy criteria in ISO15197 as a basis for gaining regulatory clearance for these devices. The current study evaluates the BGM using the accuracy guidelines issued by the agency for self-monitoring blood glucose test systems for over-the-counter use.
View Article and Find Full Text PDFBackground: Despite a marked increase in polypharmacy in patients with diabetes there have been no thorough evaluations of the impact of polypharmacy on the accuracy of any current blood glucose monitoring (BGM) system. This study evaluated the accuracy of a BGM test-strip with respect to polypharmacy using a large clinical registry dataset.
Methods: Medication profiles were analyzed for 830 subjects (334 with type 1 [T1D] and 496 with type 2 diabetes [T2D]) attending three hospitals.
Background: Accurate self-monitoring of blood glucose (SMBG) is a key component of effective self-management of glycemic control.
Methods: The OneTouch Verio Reflect and OneTouch Ultra Plus Reflect BG monitoring systems were evaluated for accuracy in a clinical setting. Subjects also used the meters for a one-week trial period and reported their level of satisfaction with meter features.
Background: Patients worldwide use lancing devices to perform self-monitoring of blood glucose (SMBG). Continued innovation remains important to minimize pain associated with finger sticking to facilitate patient adherence to SMBG regimens. The original One Touch Delica lancer (OTD) reduced the pain of testing.
View Article and Find Full Text PDFBackground: Many patients struggle to interpret and respond appropriately to the numerical blood glucose results displayed on their meter, with many regularly taking no action or self-care adjustment for out-of-range results. We recently reported that a glucose meter that provides automatic onscreen information using a color range indicator (ColorSure Technology) improved the ability of patients to categorize their blood glucose results.
Objective: The objective of this study was to examine how ColorSure Technology (or color) affected patient decision making on blood glucose results and how patient numeracy levels influenced such decisions.
Background: Anecdotal blood glucose assessments conducted by health care professionals (HCPs) in the field have highlighted differences in results when methodology used is not according to best practices for measuring blood glucose. This study assessed the impact on accuracy of blood glucose measurements when methodology deviates from the recommended study design and recommended reference instrument.
Methods: Adults with type 1 or type 2 diabetes provided capillary and venous blood samples for accuracy assessments using OneTouch® Verio® (Verio) and OneTouch® Ultra 2® (Ultra) blood glucose meters (BGM) and two different reference instruments.
Background: Mobile diabetes apps enable health care professionals (HCPs) to monitor patient progress, offer remote consultations, and allow more effective and informed treatment decisions between patients and HCPs. The OneTouch Reveal app aggregates data from a blood glucose meter and provides analytics to help patients and HCPs visualize glycemic trends and patterns, enabling more informed treatment and lifestyle decisions. The app also allows patients and HCPs to keep connected by exchanging text messages (short message service [SMS]) or progress reports via email.
View Article and Find Full Text PDFBackground: Accurate self-monitoring of blood glucose (BG) is a key component of effective self-management of glycemic control.
Methods: The OneTouch Select Plus Simple™ (OTSPS) BG monitoring system (BGMS) was evaluated for accuracy in a clinical setting.
Results: OTSPS was accurate over a wide glucose range and met lay user and system accuracy BG standards described in ISO 15197:2013.
Background: A key approach in enabling people with diabetes to better manage their condition is through self-monitoring of blood glucose (SMBG). Any functional SMBG system should demonstrate clinical accuracy across a broad glucose range and be insensitive to hematocrit. Furthermore, it should be incumbent on the manufacturer to demonstrate that their product continues to meet clinical accuracy claims during product lifetime.
View Article and Find Full Text PDFAims: We previously demonstrated that people with type 2 diabetes (T2DM) can improve their ability to categorize blood glucose (BG) results into low, in range, or high glycemic ranges after experiencing a color range indicator (CRI or ColorSure™ Technology) in a single meter. This study examined whether a CRI was effective in people with type 1 (T1) or T2DM when used in 3 glucose meters.
Methods: A total of 179 subjects (139 T2DM and 40 T1DM) classified BG values as low, in range, or high based on individual current knowledge.
Accurate self-monitoring of blood glucose is a key component of effective self-management of glycemic control. The OneTouch VerioFlex(™) (OTVF) blood glucose monitoring system (BGMS) was evaluated for accuracy in a clinical setting. Patients also used OTVF for a 1-wk trial period and reported their level of satisfaction with meter features.
View Article and Find Full Text PDFBackground: Cloud-connected diabetes applications enable health care professionals (HCPs) to monitor patient progress and offer the potential for remote consultations. OneTouch Reveal (OTR) is a cloud-based web application that aggregates data from blood glucose (BG) meters or insulin pumps and provides analytics to help patients and HCPs make more informed treatment and lifestyle decisions. This study assessed the experience of patients using OTR and the OneTouch Verio (OTV) BG meter and determined the extent of changes in glycemic control.
View Article and Find Full Text PDF