2D and 3D topographic cues made of photoresist, a polymer, are used for cell culture and cell analysis. Photoresists used for cell analysis provide the surface conditions necessary for proper cell growth, along with patterning properties of a wide range and high precision, and low auto-fluorescence that does not affect fluorescence imaging. In this study, we developed a thick negative photoresist SJI-001 possessing the aforementioned properties.
View Article and Find Full Text PDFKinesin is a motor protein that plays important roles in a variety of cellular functions. In vivo, multiple kinesin molecules are bound to cargo and work as a team to produce larger forces or higher speeds than a single kinesin. However, the coordination of kinesins remains poorly understood because of the experimental difficulty in controlling the number and arrangement of kinesins, which are considered to affect their coordination.
View Article and Find Full Text PDFThe physical fractionation of cytoplasmic versus nuclear components of cells is a key step for studying the subcellular localization of molecules. The application of an electric field is an emerging method for subcellular fractionation of proteins and nucleic acids from single cells. However, the multibiophysical process that involves electrical lysis of cytoplasmic membranes, electrophoresis, and diffusion of charged molecules remains unclear.
View Article and Find Full Text PDFCooperativity of motor proteins is essential for intracellular transport. Although their motion is unidirectional, they often cause bidirectional movement by different types of motors as seen in organelles. However, in vitro assessments of such cellular functions are still inadequate owing to the experimental limitations in precisely patterning multiple motors.
View Article and Find Full Text PDFMotor proteins function in in vivo ensembles to achieve cargo transport, flagellum motion, and mitotic cell division. Although the cooperativity of multiple motors is indispensable for physiological function, reconstituting the arrangement of motors in vitro is challenging, so detailed analysis of the functions of motor ensembles has not yet been achieved. Here, we developed an assay platform to study the motility of microtubules driven by a defined number of kinesin motors spaced in a definite manner.
View Article and Find Full Text PDFSingle-molecule fluorescence observation of adenosine triphosphate (ATP) is a powerful tool to elucidate the chemomechanical coupling of ATP with a motor protein. However, in total internal reflection fluorescence microscopy (TIRFM), available ATP concentration is much lower than that in the in vivo environment. To achieve single-molecule observation with a high signal-to-noise ratio, zero-mode waveguides (ZMWs) are utilized even at high fluorescent molecule concentrations in the micromolar range.
View Article and Find Full Text PDFWe present a microfluidic method for electrical lysis and RNA extraction from single fixed cells leveraging reversible cross-linker dithiobis(succinimidyl propionate) (DSP). Our microfluidic system captures a single DSP-fixed cell at a hydrodynamic trap, reverse-cross-links the DSP molecules on a chip with dithiothreitol, lyses the plasma membrane via electrical field, and extracts cytoplasmic RNA with isotachophoresis-aided nucleic acids extraction. All of the on-chip processes complete in less than 5 min.
View Article and Find Full Text PDFWe show that a human pluripotent stem cell (hPSC) population cultured on a low-adhesion substrate developed two hPSC subtypes with different colony morphologies: flat and domed. Notably, the dome-like cells showed higher active proliferation capacity and increased several pluripotent genes' expression compared with the flat monolayer cells. We further demonstrated that cell-matrix adhesion mediates the interaction between cell morphology and expression of KLF4 and KLF5 through a serum response factor (SRF)-based regulatory double loop.
View Article and Find Full Text PDFWe report a microfluidic system that physically separates nuclear RNA (nucRNA) and cytoplasmic RNA (cytRNA) from a single cell and enables single-cell integrated nucRNA and cytRNA-sequencing (SINC-seq). SINC-seq constructs two individual RNA-seq libraries, nucRNA and cytRNA, per cell, quantifies gene expression in the subcellular compartments, and combines them to create novel single-cell RNA-seq data. Leveraging SINC-seq, we discover distinct natures of correlation among cytRNA and nucRNA that reflect the transient physiological state of single cells.
View Article and Find Full Text PDFCurrent 3D culture models lack a vascular system to transport oxygen and nutrients, as well as cells, which is essential to maintain cellular viability and functions. Here, we describe a microfluidic method to generate a perfusable vascular network that can form inside 3D multicellular spheroids and functionally connect to microchannels. Multicellular spheroids containing endothelial cells and lung fibroblasts were embedded within a hydrogel inside a microchannel, and then, endothelial cells were seeded into both sides of the hydrogel so that angiogenic sprouts from the cell spheroids and the microchannels were anastomosed to form a 3D vascular network.
View Article and Find Full Text PDFA spheroid (a multicellular aggregate) is regarded as a good model of living tissues in the human body. Despite the significant advancement in the spheroid cultures, a perfusable vascular network in the spheroids remains a critical challenge for long-term culture required to maintain and develop their functions, such as protein expressions and morphogenesis. The protocol presents a novel method to integrate a perfusable vascular network within the spheroid in a microfluidic device.
View Article and Find Full Text PDFHigh-purity cardiomyocytes (CMs) derived from human induced pluripotent stem cells (hiPSCs) are promising for drug development and myocardial regeneration. However, most hiPSC-derived CMs morphologically and functionally resemble immature rather than adult CMs, which could hamper their application. Here, we obtained high-quality cardiac tissue-like constructs (CTLCs) by cultivating hiPSC-CMs on low-thickness aligned nanofibers made of biodegradable poly(D,L-lactic-co-glycolic acid) polymer.
View Article and Find Full Text PDFKinesin-driven microtubules have been focused on to serve as molecular transporters, called "molecular shuttles," to replace micro/nanoscale molecular manipulations necessitated in micro total analysis systems. Although transport, concentration, and detection of target molecules have been demonstrated, controllability of the transport directions is still a major challenge. Toward broad applications of molecular shuttles by defining multiple moving directions for selective molecular transport, we integrated a bottom-up molecular design of microtubules and a top-down design of a microfluidic device.
View Article and Find Full Text PDFCreating vascular networks in tissues is crucial for tissue engineering. Although recent studies have demonstrated the formation of vessel-like structures in a tissue model, long-term culture is still challenging due to the lack of active perfusion in vascular networks. Here, we present a method to create a three-dimensional cellular spheroid with a perfusable vascular network in a microfluidic device.
View Article and Find Full Text PDFHuman pluripotent stem cells (hPSCs) are thought to be a promising cell-source solution for regenerative medicine due to their indefinite proliferative potential and ability to differentiate to functional somatic cells. However, issues remain with regard to achieving reproducible differentiation of cells with the required functionality for realizing human transplantation therapies and with regard to reducing the potential for bacterial or fungal contamination. To meet these needs, we have developed a closed-channel culture device and corresponding control system.
View Article and Find Full Text PDFHuman induced pluripotent stem cells (hiPSCs) can be differentiated at high efficiency into cells of a targeting type but the resulting cell population has to be of high purity for clinical therapies to avoid teratomas. Herein, we report a microfluidic device with integrated and surface functionalised fishnet-like structures for specific cell capture. With the help of a flow derivation surface pattern, cells in solution are forced to cross the fishnet-like structure, resulting in high efficiency and selective retention of a chosen cell population.
View Article and Find Full Text PDFTau protein is a well-established biomarker for a group of neurodegenerative diseases collectively called tauopathies. So far, clinically relevant detection of tau species in cerebrospinal fluid (CSF) cannot be achieved without immunological methods. Recently, it was shown that different tau isoforms including the ones carrying various types of mutations affect microtubule (MT)-kinesin binding and velocity in an isoform specific manner.
View Article and Find Full Text PDFMechanical methods for inducing differentiation and directing lineage specification will be instrumental in the application of pluripotent stem cells. Here, we demonstrate that minimization of cell-substrate adhesion can initiate and direct the differentiation of human pluripotent stem cells (hiPSCs) into cyst-forming trophoblast lineage cells (TLCs) without stimulation with cytokines or small molecules. To precisely control cell-substrate adhesion area, we developed a novel culture method where cells are cultured on microstructured mesh sheets suspended in a culture medium such that cells on mesh are completely out of contact with the culture dish.
View Article and Find Full Text PDFMicrotubules driven by kinesin motors have been utilised as "molecular shuttles" in microfluidic environments with potential applications in autonomous nanoscale manipulations such as capturing, separating, and/or concentrating biomolecules. However, the conventional flow cell-based assay has difficulty in separating bound target molecules from free ones even with buffer flushing because molecular manipulations by molecular shuttles take place on a glass surface and molecular binding occurs stochastically; this makes it difficult to determine whether molecules are carried by molecular shuttles or by diffusion. To address this issue, we developed a microtubule-based transport system between two compartments connected by a single-micrometre-scale channel array that forms dynamically via pneumatic actuation of a polydimethylsiloxane membrane.
View Article and Find Full Text PDFOne of challenges for using microtubules (MTs) driven by kinesin motors in microfluidic environments is to control their direction of movement. Although applying physical biases to rectify MTs is prevalent, it has not been established as a design methodology in conjunction with microfluidic devices. In the future, the methodology is expected to achieve functional motor-driven nanosystems.
View Article and Find Full Text PDFThe microenvironment of cells, which includes basement proteins, shear stress, and extracellular stimuli, should be taken into consideration when examining physiological cell behavior. Although microfluidic devices allow cellular responses to be analyzed with ease at the single-cell level, few have been designed to recover cells. We herein demonstrated that a newly developed microfluidic device helped to improve culture conditions and establish a clonality-validated human pluripotent stem cell line after tracing its growth at the single-cell level.
View Article and Find Full Text PDFIntracellular cargo is transported by multiple motor proteins. Because of the force balance of motors with mixed polarities, cargo moves bidirectionally to achieve biological functions. Here, we propose a microtubule gliding assay for a tug-of-war study of kinesin and dynein.
View Article and Find Full Text PDFIn living tissues, a cell is exposed to chemical substances delivered partially to its surface. Such a heterogeneous chemical environment potentially induces cell polarity. To evaluate this effect, we developed a microfluidic device that realizes spatially confined delivery of chemical substances at subcellular resolution.
View Article and Find Full Text PDFThe simultaneous analysis of RNA and DNA of single cells remains a challenge as these species have very similar physical and biochemical properties and can cross-contaminate each other. Presented is an on-chip system that enables selective lysing of single living cells, extraction, focusing, and absolute quantification of cytoplasmic RNA mass and its physical separation from DNA in the nucleus using electrical lysing and isotachophoresis (ITP). This absolute quantitation is performed without enzymatic amplification in less than 5 min.
View Article and Find Full Text PDF