Purpose: Oxygen extraction fraction (OEF) is a biomarker for the viability of brain tissue in ischemic stroke. However, acquisition of the OEF map using positron emission tomography (PET) with oxygen-15 gas is uncomfortable for patients because of the long fixation time, invasive arterial sampling, and radiation exposure. We aimed to predict the OEF map from magnetic resonance (MR) and PET images using a deep convolutional neural network (CNN) and to demonstrate which PET and MR images are optimal as inputs for the prediction of OEF maps.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
February 2020
Purpose: The International Commission on Radiological Protection recommended that interventional radiologies (IRs) have high radiation doses and that staff may also be exposed to high doses. In the present study, we measured the radiation exposure dose [3 mm dose equivalent, Hp (3) ] in the eye using an appropriate dosimeter placed next to the physician' s eye during neurovascular intervention procedure (Neuro-IR) and interventional cardiac electrophysiology procedure (EP-IR).
Method: Physicians wore a direct eye dosemeter just lateral to the left eye and an additional direct eye dosemeter outside the radiation protective glasses close to their left eye.
Radiat Prot Dosimetry
December 2019
Interventional radiology (IR) procedures tend to be complex, which delivers high radiation exposure to patient. In the present study, we measured the radiation exposure dose [Hp(3)] in the eye using a direct eye dosemeter placed next to the physician's eye during procedures. Physicians wore a direct eye dosemeter just lateral to eyes and an additional direct eye dosemeter outside the radiation protective eyeglasses close to their eyes.
View Article and Find Full Text PDFIn a previous study, we reported on a novel (prototype) real-time patient dosimeter with non-toxic phosphor sensors. In this study, we developed new types of sensors that were smaller than in the previous prototype, and clarified the clinical feasibility of our newly proposed dosimeter. Patient dose measurements obtained with the newly proposed real-time dosimeter were compared with measurements obtained using a calibrated radiophotoluminescence glass reference dosimeter (RPLD).
View Article and Find Full Text PDFRadiat Prot Dosimetry
December 2019
Neurovascular interventional radiology (neuro-IR) procedures tend to require an extended fluoroscopic exposure time and repeated digital subtraction angiography. To evaluate the actual measurement of eye lens dose using a direct eye dosemeter in neuro-IR physicians is important. Direct dosimetry using the DOSIRIS™ (IRSN, France) [3 mm dose equivalent, Hp(3)] was performed on 86 cases.
View Article and Find Full Text PDFPseudo-continuous arterial spin labeling (pCASL) is a completely non-invasive method of cerebral perfusion measurement. However, cerebral blood flow (CBF) quantification is hampered by arterial transit artifacts characterized by bright vascular signals surrounded by decreased signals in tissue regions, which commonly appear in patients with reduced cerebral perfusion pressure. The spatial coefficient of variation (CoV) of pCASL CBF images has been proposed as an alternative region-of-interest (ROI)-based hemodynamic measure to predict prolonged arterial transit time (ATT).
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
January 2018
Purpose: CT perfusion (CTP) is a powerful tool for the assessment of cerebrovascular disease. However, CTP maps are significantly different depending on CTP software and algorithm, even when using identical image data. We developed a phase-ratio image map (PI map), which was a novel perfusion map, without using CTP software.
View Article and Find Full Text PDFThe purpose of this research was to measure accurate patient entrance skin dose and maximum skin absorbed dose (MSD) to prevent radiation skin injuries in percutaneous coronary interventions (PCIs). We directly measured the MSD on 50 PCIs by using multiple radiophotoluminescence glass dosimeters and a modified dosimetry gown. Also, we analysed the correlation between the MSD and indirect measurement parameters, such as fluoroscopic time (FT), dose-area product (DAP) and cumulative air kerma (C-AK).
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
January 2016
Deterministic effects have been reported in cardiac interventional procedures. To prevent radiation skin injuries in percutaneous coronary intervention (PCI), it is necessary to measure accurate patient entrance skin dose (ESD) and maximum skin absorbed dose (MSD). We measured the MSD on 62 patients in four facilities by using the Chest-RADIREC(Ⓡ) system.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
November 2015
CT perfusion (CTP) is obtained cerebrovascular circulation image for assessment of stroke patients; however, at the expense of increased radiation dose by dynamic scan. Iterative reconstruction (IR) method is possible to decrease image noise, it has the potential to reduce radiation dose. The purpose of this study is to assess the visual effect of IR method by using a digital perfusion phantom.
View Article and Find Full Text PDFThe volume of the temporal horn of the lateral ventricle (THLV) on brain computed tomography (CT) images is important for neurologic diagnosis. Our purpose in this study was to develop a z-score-based semi-quantitative analysis for estimation of the THLV volume by using voxel-based morphometry. The THLV volume was estimated by use of a z-score mapping method that consisted of four main steps: anatomic standardization, construction of a normal reference database, calculation of the z score, and calculation of the mean z score in a volume of interest (VOI).
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
November 2013
The purpose of this study was to evaluate the image noise reduction effect of iterative reconstruction (IR) when used to reduce radiation exposure during computed tomography (CT) perfusion. We scanned a contrast phantom using various radiation doses. Image reconstruction was via filtered back projection (FBP) and IR (adaptive iterative dose reduction 3D: AIDR3D).
View Article and Find Full Text PDFObjective: The 320-detector row computed tomography (CT) can provide whole-brain CT perfusion (CTP) maps with continuous angiographic images by performing a single dynamic scan. We investigated the reliability of CTP cerebral blood flow (CTP-CBF) with 320-detector row CT by comparing findings with O-positron emission tomography (PET-CBF).
Methods: Whole-brain CTP and PET were performed in 10 patients with chronic unilateral steno-occlusive disease.
Nihon Hoshasen Gijutsu Gakkai Zasshi
March 2009
We performed an estimation of longitudinal (T1) and transverse relaxation (T2) time using the general-purpose spreadsheet software Microsoft Excel. The Excel tool "solver" is useful for the simultaneous estimation of both T1 and steady-state magnetization from the non-linear least square method. The estimation time is quick enough for the purpose.
View Article and Find Full Text PDFCerebral vascular mean transit time (MTT), defined as the ratio of cerebral blood volume to cerebral blood flow (CBV/CBF), is a valuable indicator of the cerebral circulation. Positron emission tomography (PET) and dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSC-MRI) are useful for the quantitative determination of MTT in the clinical setting. The aim of this study was to establish a normal value set of MTT as determined by PET and by DSC-MRI and to identify differences between these methods.
View Article and Find Full Text PDFPurpose: The purpose of this study was to depict( 18)F-fluoro-2-deoxy-D: -glucose (FDG) accumulation in atherosclerotic lesions of the thoracic and carotid arteries on CT and MR images by means of automatic co-registration software.
Methods: Fifteen hospitalised men suffering cerebral infarction or severe carotid stenosis requiring surgical treatment participated in this study. Automatic co-registration of neck MR images and FDG-PET images and of contrast-enhanced CT images and FDG-PET images was achieved with co-registration software.
Purpose: Deconvolution based on truncated singular value decomposition (SVD deconvolution) is a promising method for measuring cerebral blood flow (CBF) with dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSC-MRI), but it has proved extremely sensitive to tracer delay. The purpose of this study was to investigate the effect of regional tracer delay on CBF determined by SVD deconvolution (SVD-CBF). SVD-CBFs with and without correction for the delay were compared with CBF measured by positron emission tomography (PET-CBF), which is regarded as the gold standard for quantification of CBF.
View Article and Find Full Text PDFVolume expansion associated with brain infarction occurs in perfusion-diffusion mismatch of magnetic resonance imaging. We aimed at elucidating the metabolic impairment of this phenomenon with (15)O positron emission tomography and perfusion and diffusion magnetic resonance imaging. Eleven patients with acute unilateral embolic occlusion of the internal carotid or middle cerebral artery were studied within 6 hours of onset.
View Article and Find Full Text PDFCerebral blood flow (CBF) and vascular mean transit time (MTT) can be determined by dynamic susceptibility contrast-enhanced magnetic resonance imaging and deconvolution with an arterial input function. However, deconvolution by a singular value decomposition (SVD) method is sensitive to the tracer delay that often occurs in patients with cerebrovascular disease. We investigated the effect of tracer delay on CBF determined by SVD deconvolution.
View Article and Find Full Text PDFBackground And Purpose: Acute decreases in the MR T2*-weighted signal have been reported in experimental models of middle cerebral artery occlusion. This has been attributed to blood deoxygenation in association with an increased brain oxygen extraction fraction. The aim of this study was to detect this signal by susceptibility-weighted MR imaging in acute ischemic stroke patients.
View Article and Find Full Text PDF