Introduction: Multiple groups have reported on the usefulness of ablating in atrial regions exhibiting abnormal electrograms during atrial fibrillation (AF). Still, previous studies have suggested that ablation outcomes are highly operator- and center-dependent. This study sought to evaluate a novel machine learning software algorithm named VX1 (Volta Medical), trained to adjudicate multipolar electrogram dispersion.
View Article and Find Full Text PDFBackground: The present study was designed to evaluate the respective value of left ventricular (LV) reverse remodeling (changes in LV end-systolic volume relative to baseline (ΔLVESV)) or LV performance improvement (ΔLV ejection fraction (ΔLVEF) or ΔGlobal longitudinal strain (GLS)) to predict long-term outcome in a prospective cohort of consecutive patients receiving routine cardiac resynchronization therapy (CRT).
Methods: One hundred and seventy heart failure patients (NYHA classes II-IV, LVEF ≤ 35%, QRS width ≥ 120 ms) underwent echocardiography before and 9 months after CRT. The relationships between ΔLVESV, ΔLVEF, ΔGLS and outcome (all-cause mortality and/or CHF hospitalization, overall mortality, cardiovascular mortality, CHF hospitalization) were investigated.
Background: Previous studies have demonstrated variable patterns of longitudinal septal deformation in patients with left ventricular (LV) dysfunction and left bundle branch block. This prospective single center study was designed to assess the relationship between septal deformation patterns obtained by two-dimensional speckle-tracking echocardiography and response to cardiac resynchronization therapy (CRT).
Methods: One hundred one patients with New York Heart Association class II to IV heart failure, LV ejection fractions ≤ 35%, and left bundle branch block underwent echocardiography before CRT.
Persistent left superior vena is a relatively rare congenital variant. It is, however, the most common variation of the thoracic venous system. Prevalence is estimated in about 0.
View Article and Find Full Text PDFPacing Clin Electrophysiol
September 2004
The wireless capsule video endoscopy is useful in patients with occult blood loss, but is contraindicated in patients with cardiac pacemaker (PM). No case of interference has been published. We report the case of a patient with a PM implanted in the abdominal wall.
View Article and Find Full Text PDFPacing Clin Electrophysiol
June 2003
The aim of this study was to analyze the onset mechanisms of atrial tachyarrhythmias using a dedicated diagnostic system in 83 recipients of DDDR pacemakers implanted for standard clinical indications. The pulse generator was programmed in DDD mode, at 60 beats/min, and the diagnostic instrument was programmed to document atrial tachyarrhythmic episodes at rates >200 beats/min. Onset mechanism was defined as the combination of ambient rhythm and trigger.
View Article and Find Full Text PDFMitral regurgitation is common in adults with aortic stenosis. When severe, it may aggravate the clinical condition and pose an additional therapeutic problem. The authors studied 40 consecutive patients with severe surgical aortic stenosis prospectively by transthoracic echocardiography and pre-operative transoesophageal echocardiography to determine the incidence, mechanism and degree of mitral regurgitation and its eventual relationship to the aortic stenosis.
View Article and Find Full Text PDFAnn Cardiol Angeiol (Paris)
May 1998
The authors report a case of isolated thrombus of the aortic arch discovered incidentally during thoracic CT angiography, complicated by clinical features of embolic renal infarction despite introduction of anticoagulant treatment. This case confirms the value of transoesophageal echocardiography to diagnose and follow these lesions and illustrates the therapeutic approach following discovery of aortic thrombi.
View Article and Find Full Text PDFArch Mal Coeur Vaiss
February 1998
In view of the important prognostic significance of right ventricular systolic function, there have been many non-invasive studies of this subject. The majority of these studies have been limited by difficulties in modelisation of this geometrically complex cardiac chamber. Automatic border detection by acoustic quantification based on the back scatter of ultrasound provides a "direct" method of analysing right ventricular dimensions and functions.
View Article and Find Full Text PDF