Publications by authors named "Herman F Mannaerts"

Background: We studied the value of quantitative three-dimensional echocardiography (3DE) in the evaluation of mitral valve stenosis using the measurement of the mitral valve area (MVA) with two new indices: the doming volume and mitral valve volume.

Methods And Results: A total of 45 consecutive patients with mitral valve stenosis were studied. MVA was measured using Doppler with the pressure half-time (PHT) method.

View Article and Find Full Text PDF

Objective: Registry to report our single-centre experience in closing defects of the atrial septum.

Methods: Between 1996 and 2001, transcatheter device closure of significant atrial septal defects was performed in 32 adults (mean age 45.1 years, range from 15 to 76 years), using different device types.

View Article and Find Full Text PDF

A system for analyzing left ventricular (LV) electromechanical asynchrony based on transesophageal 3-dimensional echocardiography (3-DE) and semi-automatic endocardial contour detection is described. Eighteen consecutive patients underwent 3-DE. Using TomTec 4DLV software, a 3-dimensional endocardial surface was reconstructed throughout the cardiac cycle.

View Article and Find Full Text PDF

Aims: The usefulness of 3D echocardiography (3DE) for accurate evaluation of left ventricular (LV) remodelling after acute myocardial infarction (AMI), and early identification of remodelling in the subacute phase, was assessed.

Methods And Results: Thirty-three AMI patients (21 anterior AMIs) underwent 3DE prospectively at baseline (6+/-4 days) and at 3, 6, and 12 months post-AMI. Remodelling was defined as >20% increase in end-diastolic volume (EDV) at 6 or 12 months in relation to baseline.

View Article and Find Full Text PDF

The objective of this study was to validate the additional value of 3-dimensional (3D) transesophageal echocardiography (TEE) for patients with mitral valve stenosis undergoing percutaneous mitral balloon valvotomy (PTMV). Therefore, in a series of 21 patients with severe mitral valve stenosis selected for PTMV, 3D TEE was performed before and after PTMV. The mitral valve area was assessed by planimetry pre- and post-PTMV; the mitral valve volume was assessed and attention was paid to the amount of fusion of the commissures.

View Article and Find Full Text PDF

Objectives: Our aim was to validate 3-dimensional echocardiography (3DE) for assessment of left ventricular (LV) end-diastolic volume, end-systolic volume (ESV), stroke volume, and ejection fraction (EF) using the freehand-acquisition method. Furthermore, LV volumes by breath hold-versus free breathing-3DE acquisition were assessed and compared with magnetic resonance imaging (MRI).

Methods: From the apical position, a fan-like 3DE image was acquired during free breathing and another, thereafter, during breath hold.

View Article and Find Full Text PDF

Objective: The goal of this study was to assess effects of translation (horizontal displacement) and angulation (transducer tilting) on 3-dimensional (3D) echocardiographic volumes of both balloons and human left ventricles after autopsy.

Methods: Six water-filled (non-) aneurysmatic balloons of 150, 250, and 350 mL and 3 hearts of different sizes and shapes were suspended upright in a water bath. Angulation and/or translation was performed respectively by tilting the transducer with a mechanical arm in a vertical plane relative to the balloon tip or true apex of the hearts and by shifting the water bath in the same vertical plane.