Publications by authors named "Herk M"

Purpose: To evaluate the influence of a dietary protocol on cone beam computed tomography (CBCT) image quality, which is an indirect indicator for short-term (intrafraction) prostate motion, and on interfraction motion. Image quality is affected by motion (e.g.

View Article and Find Full Text PDF

Purpose: To discuss planning target volumes (PTVs) based on internal target volume (PTVITV), exhale-gated radiotherapy (PTVGating), and a new proposed midposition (PTVMidP; time-weighted mean tumor position) and compare them with the conventional free-breathing CT scan PTV (PTVConv).

Methods And Materials: Respiratory motion induces systematic and random geometric uncertainties. Their contribution to the clinical target volume (CTV)-to-PTV margins differs for each PTV approach.

View Article and Find Full Text PDF

As radiotherapy becomes more complicated, dose and geometry verification become more necessary. The aim of this study was to use back-projected EPID-based 3D in vivo dosimetry and cone-beam CT (CBCT) to obtain a complete account of the entire treatment for a select patient group. Nine hypo-fractionated rectum IMRT patient plans were investigated.

View Article and Find Full Text PDF

Aim: To determine the reliability of visual analysis of 99mTc-HYNIC-rh-annexin-V tumour uptake (ATU) compared to quantitative tracer uptake evaluation.

Methods: Thirty-eight patients (22 male, 16 female, mean age 57) with histologically proved lymphoma (n=31), non-small cell lung cancer (NSCLC) (n=4) and head and neck squamous cell carcinoma (H&NSCC) (n=3) were examined. 99mTc-HYNIC-rh-annexin-V scintigraphy (TAS) was acquired before and within 2 days after the start of anti-cancer treatment.

View Article and Find Full Text PDF

Purpose: To quantify the interfractional variability in lung tumor trajectory and mean position during the course of radiation therapy.

Methods And Materials: Repeat four-dimensional (4D) cone-beam computed tomography (CBCT) scans (median, nine scans/patient) routinely acquired during the course of treatment were analyzed for 56 patients with lung cancer. Tumor motion was assessed by using local rigid registration of a region of interest in the 3D planning CT to each phase in the 4D CBCT.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to determine the value of (99m)Tc Hynic-rh-Annexin-V-Scintigraphy (TAVS), a non-invasive in vivo technique to demonstrate apoptosis in patients with head and neck squamous cell carcinoma.

Methods: TAVS were performed before and within 48 h after the first course of cisplatin-based chemoradiation. Radiation dose given to the tumour at the time of post-treatment TAVS was 6-8 Gy.

View Article and Find Full Text PDF

Purpose: To derive guidelines for the need to use positron emission tomography (PET) for delineation of the primary tumor (PT) according to its anatomical location in the lung.

Methods And Materials: In 22 patients with non-small-cell lung cancer, thoracic X-ray computed tomography (CT) and PET were performed. Eleven radiation oncologists delineated the PT on the CT and on the CT-PET registered scans.

View Article and Find Full Text PDF

The purpose of this work was the development of a probabilistic planning method with biological cost functions that does not require the definition of margins. Geometrical uncertainties were integrated in tumor control probability (TCP) and normal tissue complication probability (NTCP) objective functions for inverse planning. For efficiency reasons random errors were included by blurring the dose distribution and systematic errors by shifting structures with respect to the dose.

View Article and Find Full Text PDF

Purpose: To develop and evaluate a correction strategy for prostate rotation using gantry and collimator angle adjustments.

Methods And Materials: Gantry and collimator angle adjustments were used to correct for prostate rotation without rotating the table. A formula to partially correct for left-right (LR) rotations was derived through geometric analysis of rotation-induced clinical target volume (CTV) beam's-eye-view shape changes.

View Article and Find Full Text PDF

To account for geometric uncertainties during radiotherapy, safety margins are applied. In many cases, these margins overlap organs at risk, thereby limiting dose escalation. The aim of image-guided radiotherapy is to improve the accuracy by imaging tumors and critical structures on the machine just before irradiation.

View Article and Find Full Text PDF

Objective: The aim of the study was to assess the dental students' attitude towards tobacco cessation counselling in the dental setting and to explore the influence of knowledge, belief in effectiveness, smoking status, gender and curriculum.

Material And Methods: The study group consisted of all undergraduate students from the 2002-2003 classes of the Ghent University (n = 96). A validated questionnaire was administered to all students involving four different sections: demographic characteristics, attitude related to tobacco cessation programmes in the dental setting, belief in their effectiveness and knowledge concerning tobacco health effects.

View Article and Find Full Text PDF

The gamma-evaluation method is a tool by which dose distributions can be compared in a quantitative manner combining dose-difference and distance-to-agreement criteria. Since its introduction, the gamma evaluation has been used in many studies and is on the verge of becoming the preferred dose distribution comparison method, particularly for intensity-modulated radiation therapy (IMRT) verification. One major disadvantage, however, is its long computation time, which especially applies to the comparison of three-dimensional (3D) dose distributions.

View Article and Find Full Text PDF

Irradiation of the heart is one of the major concerns during radiotherapy of breast cancer. Three-dimensional (3D) treatment planning would therefore be useful but cannot always be performed for left-sided breast treatments, because CT data may not be available. However, even if 3D dose calculations are available and an estimate of the normal tissue damage can be made, uncertainties in patient positioning may significantly influence the heart dose during treatment.

View Article and Find Full Text PDF

Purpose: The short-term displacement and reproducibility of the breast or chest wall, and the internal mammary (IM), infraclavicular (ICV), and supraclavicular (SCV) nodal regions have been assessed as a function of breath-hold state using an active breathing control (ABC) device for patients receiving loco-regional breast radiation therapy.

Methods And Materials: Ten patients underwent computed tomographic scanning using an ABC device at breath-hold states of end-exhale and 20%, 40%, 60%, and 80% of vital capacity (VC). Patients underwent scanning before treatment and at one third and two thirds of the way through treatment.

View Article and Find Full Text PDF

Purpose: Kilovoltage cone-beam computed tomography (CBCT) has been developed to provide accurate soft-tissue and bony setup information. We evaluated clinical CBCT setup data and compared CBCT measurements with electronic portal imaging device (EPID) images for lung cancer patients.

Methods And Materials: The setup error for CBCT scans at the treatment unit relative to the planning CT was measured for 62 patients (524 scans).

View Article and Find Full Text PDF

Purpose: To investigate the feasibility of replacing pretreatment verification with in vivo electronic portal imaging device (EPID) dosimetry for prostate intensity-modulated radiotherapy (IMRT).

Methods And Materials: Dose distributions were reconstructed from EPID images, inside a phantom (pretreatment) or the patient (five fractions in vivo) for 75 IMRT prostate plans. Planned and EPID dose values were compared at the isocenter and in two dimensions using the gamma index (3%/3 mm).

View Article and Find Full Text PDF

Purpose: To evaluate the image quality of retrospectively attenuation corrected Positron Emission Tomography (PET) scans used for gross tumor volume (GTV) delineation in lung cancer patients.

Materials And Methods: Data of 13 lymph node positive lung cancer patients were acquired on separate CT and PET scanners under free breathing conditions (for radiotherapy planning). First we determined a protocol for CT/PET registration.

View Article and Find Full Text PDF

Purpose: To determine the planning target volume (PTV) margin for an adaptive radiotherapy procedure that uses five computed tomography (CT) scans to calculate an average prostate position and rectum shape. To evaluate alternative methods to determine an average rectum based on a single delineation.

Methods And Materials: Repeat CT scans (8-13) of 19 patients were used.

View Article and Find Full Text PDF

The aim of this study was to demonstrate how dosimetry with an amorphous silicon electronic portal imaging device (a-Si EPID) replaced film and ionization chamber measurements for routine pre-treatment dosimetry in our clinic. Furthermore, we described how EPID dosimetry was used to solve a clinical problem. IMRT prostate plans were delivered to a homogeneous slab phantom.

View Article and Find Full Text PDF

This document is the report of a task group of the AAPM and has been prepared primarily to advise medical physicists involved in the external-beam radiation therapy of patients with thoracic, abdominal, and pelvic tumors affected by respiratory motion. This report describes the magnitude of respiratory motion, discusses radiotherapy specific problems caused by respiratory motion, explains techniques that explicitly manage respiratory motion during radiotherapy and gives recommendations in the application of these techniques for patient care, including quality assurance (QA) guidelines for these devices and their use with conformal and intensity modulated radiotherapy. The technologies covered by this report are motion-encompassing methods, respiratory gated techniques, breath-hold techniques, forced shallow-breathing methods, and respiration-synchronized techniques.

View Article and Find Full Text PDF

Many studies have reported dosimetric characteristics of amorphous silicon electronic portal imaging devices (EPIDs). Some studies ascribed a non-linear signal to gain ghosting and image lag. Other reports, however, state the effect is negligible.

View Article and Find Full Text PDF

Purpose: Four-dimensional (4D) respiration-correlated imaging techniques can be used to obtain (respiration) artifact-free computed tomography (CT) images of the thorax. Current radiotherapy planning systems, however, do not accommodate 4D-CT data. The purpose of this study was to develop a simple, new concept to incorporate patient-specific motion information, using 4D-CT scans, in the radiotherapy planning process of lung cancer patients to enable smaller error margins.

View Article and Find Full Text PDF

Purpose: To evaluate the short-term and long-term reproducibility of lung tumor position for scans acquired using an active breathing control (ABC) device.

Methods And Materials: Ten patients with lung cancer were scanned over three sessions during the course of treatment. For each session, two scans were acquired at deep inhale, and one scan each at half of deep inhale and at exhale.

View Article and Find Full Text PDF

Purpose: To quantify the effect of set-up errors and respiratory motion on dose distributions for non-small cell lung cancer (NSCLC) treatment.

Methods And Materials: Irradiations of 5 NSCLC patients were planned with 3 techniques, two (conformal radiation therapy (CRT) and intensity modulated radiation therapy (IMRT1)) with a homogeneous dose in the planning target volume (PTV) and a third (IMRT2) with dose heterogeneity. Set-up errors were simulated for gross target volume (GTV) and organs at risk (OARs).

View Article and Find Full Text PDF