Background: There have been no biomechanical evaluations of naviculocuneiform (NC) joint fixation. This study compared biomechanically 3 different fixation constructs for NC-1-3 joint fixation.
Methods: The present study compared the three fixation constructs lag screw with locking plate for each NC joint, two crossed lag screws for each NC joint and a separate lag screw for each NC joint with bridging locking plates.