Background: Bioresorbable scaffolds (BRS) were developed to overcome limitations related to late stent failures of drug-eluting stents, but lumen reductions over time after implantation of BRS have been reported. This study aimed to investigate if lesion preparation with a scoring balloon compared with a standard noncompliant balloon minimizes lumen reduction after implantation of a Magmaris BRS assessed with optical coherence tomography and intravascular ultrasound.
Methods: Eighty-two patients with stable angina were randomized in a ratio of 1:1 to lesion preparation with a scoring balloon versus a standard noncompliant balloon before implantation of a Magmaris BRS.
Contemp Clin Trials Commun
April 2024
Background: Target lesion failure (TLF) remains an issue with contemporary drug-eluting stents. The dual-therapy sirolimus-eluting and CD34 antibody-coated COMBO stent (DTS) was designed to improve early healing.
Aims: We aimed to compare the 3-year outcomes of the DTS and the sirolimus-eluting Orsiro stent (SES) in all-comer patients treated with percutaneous coronary intervention.
Background: The relation between the resting full cycle ratio (RFR) and fractional flow reserve (FFR) is not fully understood. This study aims to investigate the influence of coronary microvascular dysfunction, assessed by the index of microvascular resistance (IMR), on RFR compared to FFR in patients undergoing functional assessment for coronary stenosis.
Materials And Methods: Two-hundred patients with borderline stenosis underwent functional assessment of RFR, FFR, coronary flow reserve (CFR) and IMR.
Objectives: To compare the efficacy and safety of the dual-therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (O-SES) in patients with and without acute coronary syndrome (ACS) included in the SORT OUT X study.
Background: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with ACS when compared to patients without ACS. Whether the results from the SORT OUT X study apply to patients with and without ACS remains unknown.
Objectives: To compare the efficacy and safety of the dual therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (SES) in patients with and without diabetes mellitus (DM) included in the Scandinavian Organization for Randomized Trials with Clinical Outcome (SORT OUT) X study.
Background: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with DM when compared to patients without DM. Thus, whether the results from the SORT OUT X study apply to patients with and without DM remains unknown.
EuroIntervention
June 2022
Background: For patients with high bleeding risk, the BioFreedom stent is safer and more effective than a bare metal stent. However, at the one-year follow-up of the SORT OUT IX trial, the BioFreedom stent did not meet the criteria for non-inferiority for target lesion failure (TLF) when compared with the Orsiro stent and had a higher incidence of target lesion revascularisation (TLR).
Aims: The aim of the study was to compare the two-year outcomes following coronary implantation of the BioFreedom or the Orsiro stents in all-comer patients.
Background: The purpose of a bioresorbable scaffold (BRS) is to provide radial support during coronary healing. In this study, coronary artery healing after optical coherence tomography (OCT)- versus angiography-guided magnesium BRS (MBRS) implantation in patients with non-ST-segment-elevation myocardial infarction (NSTEMI) is compared.
Methods: 75 patients were randomized 1:1 to OCT- or angiography-guided implantation of a MBRS with protocolled pre- and post-dilation.
Background: Target lesion failure remains an issue with contemporary drug-eluting stents. Thus, the dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo stent (DTS) was designed to further improve early healing. This study aimed to investigate whether the DTS is noninferior to the sirolimus-eluting Orsiro stent (SES) in an all-comers patient population.
View Article and Find Full Text PDFCardiology
August 2021
Background: Bioresorbable scaffolds (BRSs) is a relatively new approach in treating coronary artery stenosis. The initial results of the first commercially available scaffolds consisting of a backbone of poly-L-lactide raised safety concerns related to delayed resorption and healing. The magnesium alloy-based scaffold degrades via bio-corrosion within months, whereas it often takes several years for polymer scaffolds to degrade.
View Article and Find Full Text PDFBackground: A significant number of women with angina and no obstructive coronary artery disease (CAD; <50% stenosis) have coronary microvascular dysfunction (CMD) which carries an adverse cardiovascular prognosis. Coronary microvascular function can be evaluated by transthoracic Doppler echocardiography (TTDE) as a coronary flow velocity reserve (CFVR) and by static CT myocardial perfusion (CTP) as a myocardial perfusion reserve (MPR). Whether these methods are correlated is not known.
View Article and Find Full Text PDFCirculation
June 2020
Background: In patients with increased bleeding risk, the biolimus A9-coated BioFreedom stent, a stainless steel drug-coated stent free from polymer, has shown superiority compared with a bare-metal stent. The aim of this study was to investigate whether the BioFreedom stent is noninferior to a modern ultrathin strut biodegradable polymer cobalt-chromium sirolimus-eluting Orsiro stent in an all-comers patient population treated with percutaneous coronary intervention.
Methods: The SORT OUT IX trial (Scandinavian Organization for Randomized Trials With Clinical Outcome IX), was a large-scale, registry-based, randomized, multicenter, single-blind, 2-arm, noninferiority trial.
Background: Drug-eluting stents with biodegradable polymers have been designed to improve safety and efficacy. However, drug-eluting stents with biodegradable polymers may not be a class effect, as stent strut thickness, polymer coating, and drug resorption differ between these groups of stents. Twelve months results of Scandinavian Organization for Randomized Trials With Clinical Outcome VII showed that ultrathin-strut sirolimus-eluting Orsiro stent was noninferior to the biolimus-eluting Nobori stent.
View Article and Find Full Text PDFEur Heart J
February 2020
Aims: The DANish Acute Myocardial Infarction 2 (DANAMI-2) trial found that interhospital transport to primary percutaneous coronary intervention (pPCI) was superior to fibrinolysis at the local hospital in patients with ST-segment elevation myocardial infarction (STEMI) at 30 days. The present study investigates the 16-year cardiovascular outcomes.
Methods And Results: We randomized 1572 STEMI patients to pPCI or fibrinolysis at 24 referral hospitals and 5 invasive centres in Denmark.
Background: Infarct evolution rate and response to acute reperfusion therapy may differ between patients, which is important to consider for accurate management and treatment of patients with ST-elevation myocardial infarction (STEMI). The aim of this study was therefore to investigate the association of infarct size and myocardial salvage with gender, smoking status, presence of diabetes or history of hypertension in a cohort of STEMI-patients.
Methods: Patients (n = 301) with first-time STEMI from the three recent multi-center trials (CHILL-MI, MITOCARE and SOCCER) underwent cardiac magnetic resonance (CMR) imaging to determine myocardium at risk (MaR) and infarct size (IS).
Background: A link between angina with no obstructive coronary artery disease (CAD) and heart failure with preserved left ventricular ejection fraction has been proposed, but evidence in support of this is lacking. In a cross-sectional study, we investigated whether left ventricular diastolic function in women with angina pectoris and no obstructive CAD differed from a reference population.
Methods: We included 956 women with angina and <50% coronary artery stenosis at invasive coronary angiography.
Aims: The aim of the trial was to examine the influence of ezetimibe on plaque morphology in patients with ST-segment Elevation Myocardial Infarction (STEMI) with respect to fibrous cap thickness (FCT) and arcs of lipid plaque, calcific plaque, and macrophages using Optical Coherence Tomography (OCT).
Methods And Results: In 87 statin naïve patients with STEMI treated with primary percutaneous intervention, a non-culprit study plaque in a non-infarct related coronary artery was assessed with OCT at baseline and after 12 months. Patients were treated with atorvastatin 80 mg and randomized (1:1) to ezetimibe 10 mg (n = 43) or placebo (n = 44).
Background: In patients with increased bleeding risk during dual antiplatelet therapy, the biolimus A9-coated BioFreedom, a stainless steel drug-coated stent devoid of polymer, has shown superiority compared to a bare-metal stent. The aim of this study was to investigate whether the polymer-free biolimus A9-coated BioFreedom is noninferior to a modern thin-strut biodegradable polymer cobalt-chromium sirolimus-eluting Orsiro stent in an all-comers patient population treated with percutaneous coronary intervention.
Methods: The multicenter SORT OUT IX trial (NCT02623140) randomly assigned all-comers patients to treatment with the BioFreedom drug-coated stent or the biodegradable polymer Orsiro stent in 4 Danish University Hospitals.
Background: Coronary microvascular dysfunction (CMD) may cause angina in the absence of obstructive coronary artery disease (CAD) and increases the risk of future adverse cardiovascular events. Transthoracic Doppler echocardiography (TTDE) with pharmacological stress can assess coronary flow velocity reserve (CFVR), a measure of coronary microvascular function. However, simpler methods would be preferable for diagnosing CMD.
View Article and Find Full Text PDFAm Heart J
August 2018
Background: The Combo stent (OrbusNeich, Hoevelaken, the Netherlands) combining an abluminal, bioabsorbable polymer eluting sirolimus with a luminal CD34+ antibody to capture endothelial progenitor cells has been developed to further improve safety and efficacy of coronary interventions. We have designed a large-scale registry-based randomized clinical trial to compare the Combo stent to the Orsiro stent (Biotronik, Bülach, Switzerland) in patients undergoing percutaneous coronary intervention.
Methods: The SORT OUT X study will randomly assign 3,140 patients to treatment with Combo or Orsiro stents at 3 sites in Western Denmark.
Sixty percent of stroke volume (SV) is generated by atrioventricular plane displacement (AVPD) in a healthy left ventricle (LV). The aims were to determine the effect of ST-elevation myocardial infarction (STEMI) on AVPD and contribution of AVPD to SV and to study the relationship between AVPD and infarct size (IS) and location. Patients from CHILL-MI and MITOCARE studies with cardiovascular magnetic resonance within a week of STEMI (n = 177, 59 ± 11 years) and healthy controls (n = 20, 62 ± 11 years) were included.
View Article and Find Full Text PDFBackground: Coronary microvascular dysfunction (CMD) is a potential cause of myocardial ischemia and may affect myocardial function at rest and during stress. We investigated whether CMD was associated with left ventricular diastolic and systolic function at rest and during pharmacologically induced hyperemic stress.
Methods: In a prospective cohort study, we included 963 women with angina, left ventricular ejection fraction (LVEF) >45%, and an invasive coronary angiogram without significant stenosis (<50%).
Background: Terminal "QRS distortion" on the electrocardiogram (ECG) (based on Sclarovsky-Birnbaum's Grades of Ischemia Score) is a sign of severe ischemia, associated with adverse cardiovascular outcome in ST-segment elevation myocardial infarction (STEMI). In addition, ECG indices of the acuteness of ischemia (based on Anderson-Wilkins Acuteness Score) indicate myocardial salvage potential. We assessed whether severe ischemia with or without acute ischemia is predictive of infarct size (IS), myocardial salvage index (MSI) and left ventricular ejection fraction (LVEF) in anterior versus inferior infarct locations.
View Article and Find Full Text PDFBackground: Coronary vasomotor dysfunction is an important mechanism for angina in patients with unobstructed coronary arteries.
Objectives: The purpose of this study was to determine sex differences in the prevalence and clinical presentation of vasomotor dysfunction in a European population and to examine sex differences in the dose of acetylcholine leading to a positive acetylcholine provocation test (ACH test).
Methods: Between 2007 and 2014, we included 1,379 consecutive patients with stable angina, unobstructed coronaries and ACH test performed for epicardial vasospasm or coronary microvascular dysfunction (CMD) due to microvascular spasm.