Publications by authors named "Henning Tretow"

Background: Abnormal angular and torsional alignment of the lower extremities during growth are a common reason for consultation of a paediatrician or orthopaedist. There is often uncertainty about the pathological value of these abnormalities and the need for treatment, even among specialists. In the course of physiological growth and development processes, the axial and torsional alignment of the legs sometimes change considerably and in characteristic patterns.

View Article and Find Full Text PDF

Background And Purpose: Magnetically controlled motorized intramedullary lengthening nails (ILNs) can be employed for simultaneous correction of angular deformities of the distal femur and leg length discrepancy. This spares typical complications of external fixators but requires precise preoperative planning and exact intraoperative execution. To date, its results are insufficiently reported.

View Article and Find Full Text PDF

For paediatric orthopaedic surgeons treating leg length discrepancy, knowledge of the available procedures and their options and limits is just as important as mastery of the very different surgical methods and implants, as well as the possible complications, in order to be able to advise and treat the children and adolescents and their parents comprehensively and in the best interests. Both the growth inhibiting procedures and the complex bone lengthening procedures require a great deal of experience to successfully guide patients and families through what is often a lengthy and sometimes complicated treatment process. Careful preoperative indications and planning, precise surgical techniques with suitable instruments and implants, and attentive postoperative check-ups are mandatory prerequisites for the desired therapeutic success.

View Article and Find Full Text PDF

Aims: This study aims to enhance understanding of clinical and radiological consequences and involved mechanisms that led to corrosion of the Precice Stryde (Stryde) intramedullary lengthening nail in the post market surveillance era of the device. Between 2018 and 2021 more than 2,000 Stryde nails have been implanted worldwide. However, the outcome of treatment with the Stryde system is insufficiently reported.

View Article and Find Full Text PDF

Background And Purpose: The PRECICE intramedullary limb lengthening system uses a new technique with a magnetic rod and a motorized external remote controller (ERC) with rotational magnetic field. We evaluated the reliability and safety of the PRECICE system.

Methods: We compared our preliminary results with PRECICE in 24 patients (26 nails) with the known difficulties in the use of mechanical lengthening devices such as the ISKD.

View Article and Find Full Text PDF

Background: In patients with multiple cartilaginous exostosis, distal ulnar osteochondromas frequently cause forearm deformities, with relative ulnar shortening, wrist joint deviation, and varus bowing. Progressive deformation often leads to pain, functional impairment, and cosmetic problems. Surgical ulnar lengthening is necessary to restore the carpal balance.

View Article and Find Full Text PDF

Background: This research was undertaken to determine whether there is a need for a second tibial tunnel in anatomic anterior cruciate ligament reconstruction.

Hypothesis: Anatomic two-bundle reconstruction with two tibial tunnels restores knee anterior tibial translation in response to 134 N and to 5-N.m internal tibial torque combined with 10-N.

View Article and Find Full Text PDF