Purpose: The purpose of this study was to evaluate the effects of temperature and blinking on contact lens (CL) dehydration using an in vitro blink model.
Methods: Three silicone hydrogel (delefilcon A, senofilcon A, and comfilcon A) and two conventional hydrogel (etafilcon A and omafilcon A) CL materials were evaluated at 1 and 16 hours. The water content (WC) of the CLs was measured using a gravimetric method.
Significance: Previous in vitro measurements of contact lenses commonly investigate the impact of nonpolar tear film lipids (i.e., sterols).
View Article and Find Full Text PDFPurpose: The purpose of this study was to develop an advanced in vitro blink model that can be used to examine the release of a wide variety of components (for example, topical ophthalmic drugs, comfort-inducing agents) from soft contact lenses.
Methods: The model was designed using computer-aided design software and printed using a stereolithography 3D printer. The eyelid and eyeball were synthesized from polyvinyl alcohol and silicone material, respectively.
Purpose: To develop an in vitro model to determine pre-lens non-invasive break-up time (NIBUT) and to subsequently use this method to compare the NIBUT over contemporary daily disposable (DD) contact lenses (CL).
Methods: Three silicone hydrogel (SH) and two conventional hydrogel (CH) DD CLs were incubated in an artificial tear solution (ATS). A model blink cell (MBC) was utilised to mimic intermittent air exposure.
The purpose of this work was to determine the release of polyvinyl alcohol (PVA) from etafilcon A, omafilcon A, and nelfilcon A daily disposable hydrogel contact lenses using a novel in vitro model. PVA is an ocular lubricant that can be found in multiple formulations of artificial tears. Nelfilcon A innately contains PVA, so only the release of PVA from this lens was evaluated.
View Article and Find Full Text PDFPurpose: To determine the efficacy of multipurpose solutions (MPSs) on the removal of cholesterol deposits from silicone hydrogel (SH) contact lens materials using an in vitro model.
Materials And Methods: Five SH lens materials: senofilcon A, comfilcon A, balafilcon A, lotrafilcon A, and lotrafilcon B were removed from the blister pack (n=4 for each lens type), incubated for 7 days at 37°C in an artificial tear solution containing C radiolabeled cholesterol. Thereafter, lenses were stored in a preserved saline solution control (Sensitive Eyes Saline Plus) or cleaned with 1 of the 5 MPSs incorporating different preservatives (POLYQUAD/ALDOX, polyquaternium-1/alexidine, polyquaternium-1/PHMB, and 2 based on PHMB alone) using a rub and rinse technique, according to the manufacturer's recommendations, and stored in the MPS for a minimum of 6 hr.
The traditional method to measure release of components from CLs is a vial containing a static volume of PBS (phosphate buffered saline). However, this model does not simulate physiologically relevant tear volume and natural tear flow, air exposure, and mechanical rubbing. These factors can significantly impact release kinetics.
View Article and Find Full Text PDFPurpose: We evaluate the differences in lipid uptake and penetration in daily disposable (DD) contact lenses (CL) using a conventional "in-vial" method compared to a novel in vitro eye model.
Methods: The penetration of fluorescently labelled 22-(N-(7-Nitrobenz-2-Oxa-1,3-Diazol-4-yl)Amino)-23,24-Bisnor-5-Cholen-3beta-Ol (NBD)-cholesterol on three silicone hydrogel (SH) and four conventional hydrogel (CH) DD CLs were investigated. CLs were incubated for 4 and 12 hours in a vial, containing 3.
Objective: To characterize the location of fluorescently labeled lysozyme on commercial contact lenses (CLs) using an in vitro eye model that simulates tear volume, tear flow, air exposure, and mechanical wear.
Methods: One commercially available conventional hydrogel CL material (etafilcon A) and three silicone hydrogel CL materials (balafilcon A, lotrafilcon B, and senofilcon A) were evaluated in this study. The CLs were mounted on the in vitro eye model and exposed to artificial tear fluid containing fluorescein isothiocyanate (FITC)-labeled lysozyme for 2 and 10 hrs.
Currently, in vitro evaluations of contact lenses (CLs) for drug delivery are typically performed in large volume vials, which fail to mimic physiological tear volumes. The traditional model also lacks the natural tear flow component and the blinking reflex, both of which are defining factors of the ocular environment. The development of a novel model is described in this study, which consists of a unique 2-piece design, eyeball and eyelid piece, capable of mimicking physiological tear volume.
View Article and Find Full Text PDFPurpose: The goal of this study was to analyze how various incubation times affect the uptake of cholesterol on silicone hydrogel (SH) and conventional hydrogel (CH) daily disposable (DD) contact lens materials using an in vitro radiochemical detection method.
Methods: Three SH (somofilcon A, delefilcon A, and narafilcon A) and four CH (etafilcon A, nesofilcon A, ocufilcon A, and nelfilcon A) contact lenses were incubated in an artificial tear solution that contained major tear film components and a portion of radioactive C-cholesterol. Lenses (N = 4) were incubated for four incubation times (2, 6, 12, or 16 h) to assess the effects on cholesterol deposition.
Purpose: The purpose of this study was to analyze the impact that incubation time, lipid concentration, and solution replenishment have on silicone hydrogel (SiHy) and conventional hydrogel (CH) contact lens cholesterol deposition via in vitro radiochemical experiments.
Methods: Four SiHy (senofilcon A, lotrafilcon B, comfilcon A, balafilcon A) and two CH (etafilcon A and omafilcon A) contact lenses were incubated in an artificial tear solution (ATS) that contained major tear film proteins, lipids, salts, salts, and a trace amount of radioactive C-cholesterol. Lenses were incubated for various incubation times (1, 3, 7, 14, or 28 days), with three concentrations of lipid (0.