We report an ultranarrow-linewidth laser spectrometer at 657 nm, consisting of a diode laser locked in a single stage to a stable high-finesse reference cavity. The system is characterized by comparison with a second independent system. From beat frequency measurements a linewidth below 1.
View Article and Find Full Text PDFWe demonstrate a method with which to calibrate a Shack-Hartmann sensor for absolute wavefront measurement of collimated laser beams. Nearly perfect spherical wavefronts originating from a single-mode fiber were used as references. After the calibration, the uncertainty of the wavefront was less than lambda/100 peak to valley across a diameter of 6 mm.
View Article and Find Full Text PDFWe demonstrate how to realize an optical clock with neutral atoms that is competitive to the currently best single ion optical clocks in accuracy and superior in stability. Using ultracold atoms in a Ca optical frequency standard, we show how to reduce the relative uncertainty to below 10(-15). We observed atom interferences for stabilization of the laser to the clock transition with a visibility of 0.
View Article and Find Full Text PDFUltracold atoms at temperatures close to the recoil limit have been achieved by extending Doppler cooling to forbidden transitions. A cloud of (40)Ca atoms has been cooled and trapped to a temperature as low as 6 microK by operating a magnetooptical trap on the spin-forbidden intercombination transition. Quenching the long-lived excited state with an additional laser enhanced the scattering rate by a factor of 15, while a high selectivity in velocity was preserved.
View Article and Find Full Text PDFSimultaneous cw laser emission has been observed in a He-Ne discharge at 611.8-, 629.3-, 632.
View Article and Find Full Text PDFA dye laser spectrometer for ultrahigh spectral resolution is described. The laser frequency is stabilized to the side of a transmission fringe of an optical cavity by means of the usual differencing servo technique. With an intralaser-cavity AD(*)P phase modulator, driven by improved fast servo electronics, the linewidth of the jet stream dye laser was reduced to 1.
View Article and Find Full Text PDFWe used a tunable cw dye laser to observe Doppler-free two-photon transitions to alkali-atom Rydberg levels. Real-time signals were obtained in an ionization cell of appropriate construction. The two-photon transition wavelengths to rubidium s levels were measured up to n = 50 with better than 1 x 10(-7) absolute accuracy and can be represented to within the experimental precision by a simple function of the principal quantum number, Other related transitions and future possibilities are considered.
View Article and Find Full Text PDFBull Group Int Rech Sci Stomatol
October 1968
Bull Group Int Rech Sci Stomatol
October 1968
Bull Group Int Rech Sci Stomatol
October 1968
Bull Group Int Rech Sci Stomatol
October 1968
Bull Group Int Rech Sci Stomatol
October 1968
Bull Group Int Rech Sci Stomatol
October 1968
Dtsch Zahnarztl Z
September 1966