Publications by authors named "Helge Servatius"

Background: Early recurrences of atrial tachyarrhythmias (ERATs) after pulmonary vein isolation (PVI) are common. While many correlate to late recurrences (LRs), some do not. The impact of ERATs timing is difficult to assess with noninvasive Holter monitoring because of undersampling.

View Article and Find Full Text PDF
Article Synopsis
  • Single-shot devices, like the Arctic Front cryoballoon, are becoming popular for pulmonary vein isolation in atrial fibrillation, with a new option, the FARAPULSE pulsed field ablation device, aiming for better safety and effectiveness.
  • The SINGLE SHOT CHAMPION trial involves 210 patients with paroxysmal atrial fibrillation randomly assigned to either the FARAPULSE or the cryoballoon treatment, with thorough monitoring for outcomes.
  • The study's primary focus is on the first recurrence of atrial tachyarrhythmias within a year after the procedure, alongside safety measures and quality of life assessments.
View Article and Find Full Text PDF
Article Synopsis
  • - The study compared the effects of dexmedetomidine and propofol on heart function in patients undergoing atrial fibrillation ablation, focusing on how each sedative impacts sinus node function and atrioventricular (AV) conduction.
  • - A total of 160 patients were enrolled, with findings indicating that patients given dexmedetomidine experienced slower sinus rates and prolonged AV conduction times compared to those given propofol.
  • - Despite these differences, both sedatives did not significantly affect certain aspects of heart conduction, such as infrahissian AV conduction and ventricular repolarization, and arrhythmia occurrence was similar across both groups.
View Article and Find Full Text PDF

Background: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology. Its potential value for repeat procedures after unsuccessful thermal ablation for atrial fibrillation has not been assessed.

Objective: The purpose of this study was to summarize our initial experience with patients undergoing repeat procedures using PFA.

View Article and Find Full Text PDF
Article Synopsis
  • Pulmonary vein isolation is an effective treatment for atrial fibrillation, with cryoballoon ablation being superior to medication; the study compares the new PolarX cryoballoon with the existing Arctic Front cryoballoon.
  • Patients with symptomatic paroxysmal atrial fibrillation were randomly assigned to receive either cryoballoon treatment and monitored for recurrence of atrial tachyarrhythmias and procedural safety within one year.
  • Results showed that the PolarX cryoballoon had a similar effectiveness compared to Arctic Front but caused significantly more cases of phrenic nerve palsies (5% vs. 0%).
View Article and Find Full Text PDF

Aims: Pacemaker (PM) patients may require a subsequent upgrade to an implantable cardioverter defibrillator (ICD). Limited data exists on this patient population. We sought to characterize this population, to assess predictors for ICD upgrade, and to report the outcome.

View Article and Find Full Text PDF

Background: Recurrence of paroxysmal atrial fibrillation (AF) following pulmonary vein isolation (PVI) is presumably caused by pulmonary vein (PV) reconnections. However, there is little data available on the durability of PVI and incidence of arrhythmia recurrence in patients with persistent AF.

Objectives: The purpose of this study was to evaluate the lesion durability by means of an a priori planned remapping procedure in patients with persistent AF undergoing CLOSE-guided PVI.

View Article and Find Full Text PDF

Background: Pulsed-field ablation (PFA) has shown promising data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI), with similar long-term outcomes compared to radiofrequency ablation (RFA) and cryoballoon ablation (CBA) in patients with paroxysmal atrial fibrillation (AF).

Objective: The purpose of this study was to compare the procedural and long-term outcomes in patients with persistent AF undergoing PVI using PFA, CBA, or RFA.

Methods: Consecutive patients with persistent AF undergoing first PVI with PFA, CBA, or RFA were included.

View Article and Find Full Text PDF

Aims: Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood.

View Article and Find Full Text PDF

Background: Screening for atrial fibrillation (AF) may reveal incidental arrhythmias of relevance. The aim of this study was to describe incidental arrhythmias detected during screening for AF in the STAR-FIB (Predicting SilenT AtRial FIBrillation in Patients at High Thrombembolic Risk) cohort study.

Methods And Results: In the STAR-FIB cohort study, we screened hospitalized patients for AF with 3 repeat 7-day Holter ECGs.

View Article and Find Full Text PDF

Objectives: Epicardial adipose tissue (EAT) remodeling is associated with atrial fibrillation (AF). Left atrial (LA) EAT dispersion on cardiac CT is a non-invasive imaging biomarker reflecting EAT heterogeneity. We aimed to investigate the association of LA EAT dispersion with AF recurrence after pulmonary vein isolation (PVI).

View Article and Find Full Text PDF

Aims: Implantation of an implantable cardiac monitor (ICM) is a simple procedure, but adds significant and increasing workload to the arrhythmia service. In 2020, we established a nurse-led ICM implantation service. We aimed to analyse patient satisfaction, adverse events during implant, and ICM re-interventions with nurse-led ICM implantation (N-Implant) compared to physician-led ICM implantation (P-Implant).

View Article and Find Full Text PDF

Background: Pulsed-field ablation (PFA) has shown favourable data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI). We sought to compare procedural and 1-year follow-up data of patients with paroxysmal atrial fibrillation (AF) undergoing PVI using PFA, cryoballoon ablation (CBA) and radiofrequency ablation (RFA).

Methods: Consecutive patients with paroxysmal AF undergoing a first PVI with PFA at our institution were included.

View Article and Find Full Text PDF
Article Synopsis
  • The study examines the effectiveness of two cryoballoon devices (PolarX and Arctic Front) for treating atrial fibrillation through a multicenter, randomized clinical trial involving 200 patients.
  • The primary goal is to determine the time until the first recurrence of atrial tachyarrhythmias within a year after the procedure, alongside assessing procedural safety and various secondary outcomes like quality of life and repeat procedures.
  • The trial aims to provide insights on whether the new PolarX device can surpass the established Arctic Front technology for pulmonary vein isolation in patients experiencing their first episode of atrial fibrillation.
View Article and Find Full Text PDF

Background: Prediction of the chamber of origin in patients with outflow tract ventricular arrhythmias (OTVA) remains challenging. A clinical risk score based on age, sex and presence of hypertension was associated with a left ventricular outflow tract (LVOT) origin. We aimed to validate this clinical score to predict an LVOT origin in patients with OTVA.

View Article and Find Full Text PDF

Background: A novel multipolar pulsed-field ablation (PFA) catheter has recently been introduced for pulmonary vein isolation (PVI). Pre-market data showed high rates for PVI-durability during mandatory remapping studies.

Objective: To present post-market data in patients with recurrent arrhythmias.

View Article and Find Full Text PDF

Introduction: Anomalous cardiac veins are not rare and pulmonary vein (PV) isolation for atrial fibrillation (AF) treatment should include these veins. Pulsed-field ablation (PFA) is a novel technology for AF ablation with excellent efficacy and safety profile. In this case series, we describe our first experience of isolation of anomalous cardiac veins using PFA in patients with AF.

View Article and Find Full Text PDF

Background: The implantation procedure of left ventricular (LV) leads and the management of cardiac resynchronization therapy (CRT) patients can be challenging. The IS-4 standard for CRT offers additional pacing vectors compared to bipolar leads (IS-1). IS-4 leads improve procedural outcome and may also result in lower adverse events during follow-up (FU) and improve clinical outcome in CRT patients.

View Article and Find Full Text PDF

Background: We describe our initial experience using a multipolar pulsed-field ablation catheter for the treatment of left atrial (LA) reentry tachycardia.

Methods: We included all patients with LA reentry tachycardia treated with PFA at our institution between September 2021 and March 2022. The tachycardia mechanism was identified using 3D electro-anatomical mapping (3D-EAM).

View Article and Find Full Text PDF

Background: Congenital long-QT syndrome (LQTS) is a major cause of sudden cardiac death (SCD) in young individuals, calling for sophisticated risk assessment. Risk stratification, however, is challenging as the individual arrhythmic risk varies pronouncedly, even in individuals carrying the same variant.

Materials And Methods: In this study, we aimed to assess the association of different electrical parameters with the genotype and the symptoms in patients with LQTS.

View Article and Find Full Text PDF

Aims: The aim of the study was to compare the 1-year efficacy and safety of a novel cryoballoon (NCB) ablation system (POLARx; Boston Scientific) for pulmonary vein isolation (PVI) compared with the standard cryoballoon (SCB) system (Arctic Front, Medtronic).

Methods And Results: Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SCB at two centres were included. We report 1-year efficacy after 12 months, short-term safety and hospitalizations within the blanking period, and predictors for AF recurrence.

View Article and Find Full Text PDF

Aims: To validate the performance of a multipolar pulsed-field ablation (PFA) catheter compared to a standard pentaspline 3D-mapping catheter for endpoint assessment of pulmonary vein isolation (PVI). PFA for PVI using single-shot devices combines the benefits of high procedural efficacy and safety. A newly available multipolar PFA catheter allows real-time recording of pulmonary vein (PV) signals during PVI.

View Article and Find Full Text PDF

Background The association of epicardial adipose tissue (EAT) and its metabolic activity with atrial fibrillation (AF) is an area of active investigation. Left atrial (LA) enhancing EAT (e-EAT) at cardiac CT may be a noninvasive surrogate marker for the metabolic activity of EAT. Purpose To determine the relationship between LA e-EAT and recurrence after AF ablation.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve implantation (TAVI) is associated with new onset brady- and tachyarrhythmias which may impact clinical outcome.

Aims: To investigate the true incidence of new onset arrhythmias within 12 months after TAVI using an implantable cardiac monitor (ICM).

Methods: One hundred patients undergoing TAVI received an ICM within 3 months before or up to 5 days after TAVI.

View Article and Find Full Text PDF