Background: There has been no large evaluation of the ISHLT 2004 acute cellular rejection grading scheme for heart graft endomyocardial biopsy specimens (EMBs).
Methods: We evaluated agreement within the CARGO II pathology panel and between the panel (acting by majority) and the collaborating centers (treated as a single entity), regarding the ISHLT grades of 937 EMBs (with all grades ≥2R merged because of small numbers).
Results: Overall all-grade agreement was almost 71% both within the panel and between the panel and the collaborating centers but, in both cases, was largely because of agreement on grade 0: for the average pair of pathologists, fewer than a third of the EMBs assigned grade ≥2R by at least one were assigned this grade by both.
Objective: Infections are among the most common and serious complications of ventricular assist device implantation. These infections generally occur within the first 2 months after surgery. The basis for this high incidence of infection is not well established, so a murine intravascular infection model was developed with aortic implantation of the textured polyurethane patch material currently used in HeartMate ventricular assist devices (Thoratec Corporation Pleasanton, Calif).
View Article and Find Full Text PDFVentricular assist devices (VADs) are an important form of therapy for end-stage congestive heart failure. However, infection of the VAD, which is often caused by Staphylococcus aureus, poses a major threat to survival. Using a novel in vitro binding assay with VAD membranes and a heterologous lactococcal system of expression, we identify 3 S.
View Article and Find Full Text PDFEndomyocardial biopsy is the mainstay for monitoring cardiac allograft rejection. A noninvasive strategy--peripheral blood gene expression profiling of circulating leukocytes--is an alternative with proven benefits, but unclear economic implications. Financial data were obtained from five cardiac transplant centers.
View Article and Find Full Text PDF