His bundle pacing has been proposed as a more physiologic approach to chronic ventricular stimulation, yet the achievement of permanent His bundle pacing can be challenging.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
April 2023
Background: His bundle (HB) pacing techniques are challenging and time-consuming. This is primarily due to the limitations in locating the relatively small area of the HB body for pacing.
Methods: Permanent HB pacing was performed in 133 consecutive patients with symptomatic bradycardia.
Atrioventricular node (AVN) ablation is a strategy to manage patients with drug-refractory atrial fibrillation (AF) and heart failure in whom cardiac resynchronization therapy (CRT) device implantation has been prescribed. This study describes a practical method to perform these two procedures using the same surgical site. Twenty-seven patients were indicated for AVN ablation and concurrent CRT device implantation while presenting with AF and rapid ventricular response (RVR) refractory to medical therapy.
View Article and Find Full Text PDFObjectives: This study sought to determine whether the nonabsorbable TYRX Antibacterial Envelope (TYRX) reduces major cardiovascular implantable electronic device (CIED) infections 12 months after implant.
Background: TYRX is a monofilament polypropylene mesh impregnated with minocycline and rifampin specifically designed to hold a CIED in place and elute antimicrobials over time. There are limited data on its ability to reduce CIED infections.
Aims: Right ventricular (RV) pacing has been shown to be potentially detrimental to left ventricular function. In conventional dual-chamber pacing the position of the atrial lead could influence duration of the atrio-ventricular (AV) intervals, which is one of the variables that could be associated with an increased percentage of RV pacing. We wanted to see if lead placement at selected atrial septal sites could reduce AV intervals in patients receiving a dual-chamber pacemaker or implantable cardioverter defibrillator.
View Article and Find Full Text PDFIntroduction: Previous studies have suggested that, among septal sites, the inferior portion of the interatrial septum (IAS) is the most likely to prevent atrial fibrillation, though inserting an active fixation lead at this site can be tedious and time consuming. We describe a relatively straightforward technique to insert a lead at this site without special tools.
Method: We studied 117 consecutive patients (mean age = 76 +/- 8 years, 69% men) with ACC/AHA class I and II pacing indications and histories of paroxysmal or permanent atrial fibrillation, undergoing implantation of a dual chamber pacing system.
This is a case report of a male patient with nonischemic cardiomyopathy who had severely depressed left ventricular systolic function and functional class III congestive heart failure (CHF). He also had left bundle branch block (LBBB) and recurrent ventricular tachycardia (VT). Though the patient's CFH functional class improved after implantation of a transvenous biventricular ICD system, recurrent VT episodes required the initiation of amiodarone.
View Article and Find Full Text PDFBackground: Delivery of inappropriate shocks caused by misdetection of supraventricular tachycardia (SVT) remains a substantial complication of implanted cardioverter/defibrillator (ICD) therapy. Whether use of optimally programmed dual-chamber ICDs lowers this risk compared with that in single-chamber ICDs is not clear.
Methods And Results: Subjects with a clinical indication for ICD (n=400) at 27 participating centers received dual-chamber ICDs and were randomly assigned to strictly defined optimal single- or dual-chamber detection in a single-blind manner.
Pacing Clin Electrophysiol
January 2005
AutoCapture (AC) can confirm ventricular capture with true bipolar single coil leads of implantable cardioverter defibrillators (ICD). The compatibility of AC with a new, true bipolar, dual-coil ICD lead needed to be evaluated. This multicenter study enrolled 46 patients (69 +/- 10 years, 37 men) undergoing ICD implantation.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
February 2002
Introduction: Serum cardiac troponin I (cTnI) is a sensitive and specific marker for myocardial injury. Myocardial ischemia and/or injury can be a trigger for ventricular arrhythmias. The aim of this study was to assess the frequency and significance of elevated serum cTnI levels after spontaneous implantable cardioverter defibrillator (ICD) shocks.
View Article and Find Full Text PDF