Publications by authors named "Heiko Lehrmann"

Background: The prognostic value of (non)-invasive programmed ventricular stimulation (NIPS) to predict recurrences of ventricular tachycardia (VT) is under discussion. Optimal endpoints of VT ablation are not well defined, and optimal timepoint of NIPS is unknown. The goal of this study was to evaluate the ability of programmed ventricular stimulation at the end of the VT ablation procedure (PVS) and NIPS after VT ablation to identify patients at high risk for VT recurrence.

View Article and Find Full Text PDF

Background: Patients undergoing ventricular tachycardia (VT) ablation often present with structural heart disease (SHD) and reduced ejection fraction. Inducing VT by programmed electrical stimulation (PES) puts these patients at risk for hemodynamic instability and cerebral hypoperfusion.

Objective: The present study screens for cerebral oxygen desaturation phases (ODPs) in patients undergoing VT ablation.

View Article and Find Full Text PDF
Article Synopsis
  • Pulsed field ablation (PFA) is a new method for treating atrial fibrillation (AF) that focuses on ablating heart tissue while minimizing harm to nearby structures.
  • In the MANIFEST-17K study, data from 106 centers involved 17,642 patients and showed no serious complications like esophageal damage, with only a 1% major complication rate.
  • The results suggest that PFA has a strong safety profile and may change how AF is treated, compared to traditional thermal ablation methods.
View Article and Find Full Text PDF

Background: It is currently unknown whether 3D-mapping and micro-electrodes add meaningful benefits in catheter ablation of Wolff-Parkinson-White (WPW) syndrome and challenging, e.g. -Hisian accessory pathways (APs).

View Article and Find Full Text PDF

Background: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF).

Objective: To assess the outcomes of pulsed-field ablation (PFA) in HF.

View Article and Find Full Text PDF

Background: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF).

Objective: This study sought to assess the outcomes of pulsed field ablation (PFA) in HF.

View Article and Find Full Text PDF
Article Synopsis
  • Brugada syndrome (BrS) is associated with abnormal heart rhythms, particularly ST-elevations in specific leads, increasing the risk of sudden cardiac death, and understanding its mechanisms can be aided by computational modeling.
  • Researchers tested two main hypotheses—'delayed depolarization' and 'early repolarization'—using a 3D whole-heart computational model that simulated different ionic changes affecting the heart's electrical activity.
  • Results showed that realistic coved-type ST-elevation, characteristic of BrS, was only produced by delayed epicardial depolarization, supporting the depolarization hypothesis and suggesting early repolarization does not play a significant role in the ECG changes observed in BrS.
View Article and Find Full Text PDF
Article Synopsis
  • Pulmonary vein isolation (PVI) alone is often inadequate for treating persistent atrial fibrillation, and adding left atrial posterior wall (LAPW) ablation has had mixed results due to concerns about safety and effectiveness.
  • This study compares the safety and effectiveness of PVI combined with LAPW ablation versus PVI alone using pulsed-field ablation (PFA) in patients with persistent atrial fibrillation.
  • Results show no significant difference in freedom from arrhythmias or major adverse events between the two groups, indicating that adding LAPW ablation may not improve outcomes in this patient population.
View Article and Find Full Text PDF
Article Synopsis
  • Epicardial ablation is a treatment for a heart problem called ventricular tachycardias (VT), and this study looks at how safe and effective it is.
  • The study examined 197 patients over several years and found that while some had complications, most procedures were successful in accessing the heart.
  • About half of the patients showed no more VT after the treatment, highlighting that both the special fluid used (D5W) and regular saline were effective options.
View Article and Find Full Text PDF

Background: Pulmonary vein isolation (PVI) is an effective treatment option for patients with symptomatic atrial fibrillation (AF). However, the electrical recovery of pulmonary veins (PVs) is the main trigger for AF recurrences. This study investigates the characteristics of patients admitted for redo AF ablation, the PV reconnection rates depending on previous ablation modalities and the impact of different ablation strategies for redo procedures.

View Article and Find Full Text PDF

Importance: Previous studies evaluating the association of patient sex with clinical outcomes using conventional thermal ablative modalities for atrial fibrillation (AF) such as radiofrequency or cryoablation are controversial due to mixed results. Pulsed field ablation (PFA) is a novel AF ablation energy modality that has demonstrated preferential myocardial tissue ablation with a unique safety profile.

Objective: To compare sex differences in patients undergoing PFA for AF in the Multinational Survey on the Methods, Efficacy, and Safety on the Postapproval Clinical Use of Pulsed Field Ablation (MANIFEST-PF) registry.

View Article and Find Full Text PDF

Aims: Electro-anatomical voltage, conduction velocity (CV) mapping, and late gadolinium enhancement (LGE) magnetic resonance imaging (MRI) have been correlated with atrial cardiomyopathy (ACM). However, the comparability between these modalities remains unclear. This study aims to (i) compare pathological substrate extent and location between current modalities, (ii) establish spatial histograms in a cohort, (iii) develop a new estimated optimized image intensity threshold (EOIIT) for LGE-MRI identifying patients with ACM, (iv) predict rhythm outcome after pulmonary vein isolation (PVI) for persistent atrial fibrillation (AF).

View Article and Find Full Text PDF
Article Synopsis
  • - Interventional electrophysiology provides various treatments for patients with cardiac arrhythmias, with catheter ablation being a key method for managing tachycardias.
  • - The field has advanced significantly, using multiple ablation tools and techniques to improve the accuracy of procedures while relying heavily on fluoroscopy for guidance.
  • - However, the use of X-ray technology presents health risks, prompting a focus on strategies to minimize fluoroscopy use and enhance radiation protection for both patients and healthcare providers.
View Article and Find Full Text PDF

Introduction: Improved sinus rhythm (SR) maintenance rates have been achieved in patients with persistent atrial fibrillation (AF) undergoing pulmonary vein isolation plus additional ablation of low voltage substrate (LVS) during SR. However, voltage mapping during SR may be hindered in persistent and long-persistent AF patients by immediate AF recurrence after electrical cardioversion. We assess correlations between LVS extent and location during SR and AF, aiming to identify regional voltage thresholds for rhythm-independent delineation/detection of LVS areas.

View Article and Find Full Text PDF

Background: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care.

View Article and Find Full Text PDF

Aim: This study sought to develop and validate diagnostic models to identify individuals with atrial fibrillation (AF) using amplified sinus-p-wave analysis.

Methods: A total of 1,492 patients (491 healthy controls, 499 with paroxysmal AF and 502 with persistent AF) underwent digital 12-lead-ECG recording during sinus rhythm. The patient cohort was divided into training and validation set in a 3:2 ratio.

View Article and Find Full Text PDF

Aims: With recurrence rates up to 50% after pulmonary vein isolation (PVI) in persistent atrial fibrillation (AF), predictive tools to improve patient selection are needed. Patient selection based on left atrial late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) has been proposed previously (UTAH-classification). However, this approach has not been widely established, in part owed to the lack of standardization of the LGE quantification method.

View Article and Find Full Text PDF

Aims: Transseptal puncture (TP) for left-sided catheter ablation procedures is routinely performed under fluoroscopic or echocardiographic guidance [transoesophageal echocardiography (TEE) or intracardiac echocardiography (ICE)], although three-dimensional (3D) mapping systems are readily available in most electrophysiology laboratories. Here, we sought to assess the feasibility and safety of a right atrial (RA) 3D map-guided TP.

Methods And Results: In 104 patients, 3D RA mapping was performed to identify the fossa ovalis (FO) using the protrusion technique.

View Article and Find Full Text PDF

Background: Low-voltage-substrate (LVS)-guided ablation for persistent atrial fibrillation (AF) has been described either in sinus rhythm (SR) or AF. Prolonged fractionated potentials (PFPs) may represent arrhythmogenic slow conduction substrate and potentially co-localize with LVS. We assess the spatial correlation of PFP identified in AF (PFP-AF) to those mapped in SR (PFP-SR).

View Article and Find Full Text PDF

Introduction: Phrenic nerve (PN) injury is a rare but severe complication of radiofrequency (RF) pulmonary vein isolation (PVI). The objective of this study was to characterize the typical intracardiac course of the PN with a three-dimensional electroanatomic mapping system, to quantify the need for modification of the ablation trajectory to avoid delivering an ablation lesion on sites with PN capture, and to identify very circumscribed areas of common PNC on the routine ablation trajectory of a RF-PVI, allowing fast and effective PN screening for everyday usage.

Methods: We enrolled 137 consecutive patients (63 ± 9 years, 64% men) undergoing PVI.

View Article and Find Full Text PDF

Aims: The cornerstone of pulmonary vein (PV) isolation (PVI) is a wide-area circumferential ablation (WACA) resulting in an antral PVI area. Pulsed-field ablation (PFA) is a new nonthermal 'single-shot' PVI technique resulting in well-characterized posterior isolation areas. However, information on circumferential PVI area is lacking.

View Article and Find Full Text PDF

Background: The Octaray (Biosense Webster) is a novel, multispline mapping catheter with 48 closely spaced microelectrodes enabling high-resolution electroanatomical mapping.

Objectives: This study sought to report the initial clinical mapping experience with this novel catheter in a variety of cardiac arrhythmias and to compare the mapping performance with the 5-spline Pentaray.

Methods: Fifty consecutive procedures among 46 patients were retrospectively analyzed regarding safety, efficacy, and acute procedural success defined as termination or noninducibility of clinical tachycardia, conduction block across an ablation line, or pulmonary vein isolation.

View Article and Find Full Text PDF

Aims: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications.

Methods And Results: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval.

View Article and Find Full Text PDF

Aims: Atrial cardiomyopathy (ACM) is associated with increased arrhythmia recurrence rates after pulmonary vein isolation (PVI). We compare the most common left atrial (LA) late gadolinium enhancement magnetic resonance imaging (LGE-MRI)-methods [Utah-method and image intensity ratio (IIR)-methods] and endocardial voltage mapping for ACM-detection and outcome prediction after PVI for atrial fibrillation (AF).

Methods And Results: In this prospective observational study, 37 ablation-naive patients (66 ± 9 years, 84% male) with persistent AF underwent LA-LGE-MRI and high-definition voltage and activation mapping (2129 ± 484 sites) in sinus rhythm prior to PVI.

View Article and Find Full Text PDF

Objective: Atrial cardiomyopathy (ACM) is associated with development of AF, left atrial (LA) thrombogenesis, and stroke. Diagnosis of ACM is feasible using both echocardiographic LA strain imaging and measurement of the amplified p-wave duration (APWD) in digital 12-lead-ECG. We sought to determine the thresholds of LA global longitudinal strain (LA-GLS) and APWD that identify patients with AF at risk for LA appendage (LAA) thrombogenesis.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionp5jt0l9oaoi9rt1tvtjvppqcn3o1ms2j): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once