RNA-based therapeutics, including siRNA, have obtained recognition in recent years due to their potential to treat various chronic and rare diseases. However, there are still limitations to lipid-based drug delivery systems in the clinical use of RNA therapeutics due to the need for optimization in the design and the preparation process. In this study, we propose adaptive focused ultrasound (AFU) as a drug loading technique to protect RNA from degradation by encapsulating small RNA in nanoliposomes, which we term nanoplexes.
View Article and Find Full Text PDFAdv Sci (Weinh)
September 2024
Superhydrophobic surfaces (SHS) exhibit a pronounced ability to resist wetting. When immersed in water, water does not penetrate between the microstructures of the SHS. Instead, a thin layer of trapped gas remains, i.
View Article and Find Full Text PDFObjective: Needle biopsy is a common technique used to obtain cell and tissue samples for diagnostics. Currently, two biopsy methods are widely used: (i) fine-needle aspiration biopsy (FNAB) and (ii) core needle biopsy (CNB). However, these methods have limitations.
View Article and Find Full Text PDFJ Acoust Soc Am
November 2023
Annually, more than 16 × 109 medical needles are consumed worldwide. However, the functions of the medical needle are still limited mainly to cutting and delivering material to or from a target site. Ultrasound combined with a hypodermic needle could add value to many medical applications, for example, by reducing the penetration force needed during the intervention, adding precision by limiting the needle deflection upon insertion into soft tissues, and even improving tissue collection in fine-needle biopsy applications.
View Article and Find Full Text PDFBioactive glass (BAG) is a bone substitute that can be used in orthopaedic surgery. Following implantation, the BAG is expected to be replaced by bone via bone growth and gradual degradation of the BAG. However, the hydroxyapatite mineral forming on BAG resembles bone mineral, not providing sufficient contrast to distinguish the two in X-ray images.
View Article and Find Full Text PDFIt has been recently demonstrated that use of ultrasound increases the tissue yield in ultrasound-enhanced fine-needle aspiration biopsy (USeFNAB) as compared to conventional fine-needle aspiration biopsy (FNAB). To date, the association between bevel geometry and needle tip action has not been widely explored. In this study, we studied the needle resonance characteristics and deflection magnitude of various needle bevel geometries with varying bevel lengths.
View Article and Find Full Text PDFNon-invasive therapeutic ultrasound (US) methods, such as high-intensity focused ultrasound (HIFU), have limited access to tissue targets shadowed by bones or presence of gas. This study demonstrates that an ultrasonically actuated medical needle can be used to translate nanoparticles and fluids under the action of nonlinear phenomena, potentially overcoming some limitations of HIFU. A simulation study was first conducted to study the delivery of a tracer with an ultrasonically actuated needle (33 kHz) inside a porous medium acting as a model for soft tissue.
View Article and Find Full Text PDFUltrasonic cavitation is being used in medical applications as a way to influence matter, such as tissue or drug vehicles, on a micro-scale. Oscillating or collapsing cavitation bubbles provide transient mechanical force fields, which can, e.g.
View Article and Find Full Text PDFDespite the ubiquitous use over the past 150 years, the functions of the current medical needle are facilitated only by mechanical shear and cutting by the needle tip, i.e. the lancet.
View Article and Find Full Text PDFWe provide research findings on the physics of aerosol and droplet dispersion relevant to the hypothesized aerosol transmission of SARS-CoV-2 during the current pandemic. We utilize physics-based modeling at different levels of complexity, along with previous literature on coronaviruses, to investigate the possibility of airborne transmission. The previous literature, our 0D-3D simulations by various physics-based models, and theoretical calculations, indicate that the typical size range of speech and cough originated droplets ( ) allows lingering in the air for ) so that they could be inhaled.
View Article and Find Full Text PDFPeople suffering from glaucoma often endure high intra-ocular pressure (IOP). Methods for determining IOP either contact the eye or are unpleasant to some patients. There is therefore a need for a rapid and patient friendly non-contacting method to determine IOP.
View Article and Find Full Text PDFLocalized delivery of drugs into an osteoarthritic cartilaginous lesion does not yet exist, which limits pharmaceutical management of osteoarthritis (OA). High-intensity focused ultrasound (HIFU) provides a means to actuate matter from a distance in a non-destructive way. In this study, we aimed to deliver methylene blue locally into bovine articular cartilage in vitro.
View Article and Find Full Text PDFWe investigated nozzleless ultrasound-enhanced electrospinning (USES) as means to generate nanofibrous drug delivery systems (DDSs) for pharmaceutical and biomedical applications. Traditional electrospinning (TES) equipped with a conventional spinneret was used as a reference method. High-molecular polyethylene oxide (PEO) and chitosan were used as carrier polymers and theophylline anhydrate as a water-soluble model drug.
View Article and Find Full Text PDFArch Pathol Lab Med
November 2019
Context.—: Needle biopsy of diseased tissue is an essential diagnostic tool that is becoming even more important as precision medicine develops. However, the capability of this modality to efficiently provide samples adequate for diagnostic and prognostic analysis remains quite limited relative to current diagnostic needs.
View Article and Find Full Text PDFStudies in optics and acoustics have employed metamaterial lenses to achieve sub-wavelength localization, e.g. a recently introduced concept called 'acoustojet' which in simulations localizes acoustic energy to a spot smaller than λ/2.
View Article and Find Full Text PDFOne of the earliest changes in osteoarthritis (OA) is a surface discontinuity of the articular cartilage (AC), and these surface changes become gradually more complex with OA progression. We recently developed a contrast enhanced micro-computed tomography (μCT) method for visualizing AC surface in detail. The present study aims to introduce a μCT analysis technique to parameterize these complex AC surface features and to demonstrate the feasibility of using these parameters to quantify degenerated AC surface.
View Article and Find Full Text PDFElectrospinning is commonly used to produce polymeric nanofibers. Potential applications for such fibers include novel drug delivery systems, tissue engineering scaffolds, and filters. Electrospinning, however, has shortcomings such as needle clogging and limited ability to control the fiber-properties in a non-chemical manner.
View Article and Find Full Text PDFResearch is ongoing to develop drug therapies to manage osteoarthritis (OA) and articular cartilage (AC) injuries. However, means to deliver drug to localized AC lesions are highly limited and not clinically available. This study investigates the capability of laser ultrasound (laser-induced plasma sound source) to deliver agents (methylene blue, MB, in PBS) into bovine AC.
View Article and Find Full Text PDFContrast-enhanced micro-computed tomography (CEμCT) with phosphotungstic acid (PTA) has shown potential for detecting collagen distribution of articular cartilage. However, the selectivity of the PTA staining to articular cartilage constituents remains to be elucidated. The aim of this study was to investigate the dependence of PTA for the collagen content in bovine articular cartilage.
View Article and Find Full Text PDFAcoustic levitation provides potential to characterize and manipulate material such as solid particles and fluid in a wall-less environment. While attempts to levitate small animals have been made, the biological effects of such levitation have been scarcely documented. Here, our goal was to explore if zebrafish embryos can be levitated (peak pressures at the pressure node and anti-node: 135 dB and 144 dB, respectively) with no effects on early development.
View Article and Find Full Text PDFThere is no cure for osteoarthritis. Current drug delivery relies on systemic delivery or injections into the joint. Because articular cartilage (AC) degeneration can be local and drug exposure outside the lesion can cause adverse effects, localized drug delivery could permit new drug treatment strategies.
View Article and Find Full Text PDFPurpose: Up to 25% of women suffer from uterine fibroids (UF) that cause infertility, pain, and discomfort. MR-guided high intensity focused ultrasound (MR-HIFU) is an emerging technique for noninvasive, computer-guided thermal ablation of UFs. The volume of induced necrosis is a predictor of the success of the treatment.
View Article and Find Full Text PDFPurpose: To evaluate the accuracy of the size and location of the ablation zone produced by volumetric magnetic resonance (MR) imaging-guided high-intensity focused ultrasound ablation of uterine fibroids on the basis of MR thermometric analysis and to assess the effects of a feedback control technique.
Materials And Methods: This prospective study was approved by the institutional review board, and written informed consent was obtained. Thirty-three women with 38 uterine fibroids were treated with an MR imaging-guided high-intensity focused ultrasound system capable of volumetric feedback ablation.
Purpose: To describe the preliminary safety and accuracy of a magnetic resonance (MR) imaging-guided high-intensity-focused ultrasound (HIFU) system employing new technical developments, including ablation control via volumetric thermal feedback, for the treatment of uterine leiomyomata with histopathologic correlation.
Materials And Methods: In this phase I clinical trial, 11 women underwent MR-guided HIFU ablation (Sonalleve 1.5T; Philips Medical Systems, Vantaa, Finland), followed by hysterectomy within 30 days.
Ultrasound indentation measurements have been shown to provide means to assess cartilage integrity and mechanical properties. To determine cartilage stiffness in the ultrasound indentation geometry, cartilage is compressed with an ultrasound transducer to determine the induced strain from the ultrasound signal using the time-of-flight principle. As the ultrasound speed in cartilage has been shown to vary during compression, the assumption of constant speed generates significant errors in the values of mechanical parameters.
View Article and Find Full Text PDF