Objectives: In multiple myeloma and its precursor stages, plasma cell infiltration (PCI) and cytogenetic aberrations are important for staging, risk stratification, and response assessment. However, invasive bone marrow (BM) biopsies cannot be performed frequently and multifocally to assess the spatially heterogenous tumor tissue. Therefore, the goal of this study was to establish an automated framework to predict local BM biopsy results from magnetic resonance imaging (MRI).
View Article and Find Full Text PDFInvest Radiol
September 2022
Objectives: The aim of this study was to estimate the prospective utility of a previously retrospectively validated convolutional neural network (CNN) for prostate cancer (PC) detection on prostate magnetic resonance imaging (MRI).
Materials And Methods: The biparametric (T2-weighted and diffusion-weighted) portion of clinical multiparametric prostate MRI from consecutive men included between November 2019 and September 2020 was fully automatically and individually analyzed by a CNN briefly after image acquisition (pseudoprospective design). Radiology residents performed 2 research Prostate Imaging Reporting and Data System (PI-RADS) assessments of the multiparametric dataset independent from clinical reporting (paraclinical design) before and after review of the CNN results and completed a survey.
Background/objectives: Apparent diffusion coefficient (ADC) and signal intensity (SI) measurements play an increasing role in magnetic resonance imaging (MRI) of monoclonal plasma cell disorders. The purpose of this study was to assess interrater variability, repeatability, and reproducibility of ADC and SI measurements from bone marrow (BM) under variation of MRI protocols and scanners.
Patients And Methods: Fifty-five patients with suspected or confirmed monoclonal plasma cell disorder were prospectively included in this institutional review board-approved study and underwent several measurements after the standard clinical whole-body MR scan, including repeated scan after repositioning, scan with a second MRI protocol, scan at a second 1.
Background: In 2014, the diagnostic criteria for multiple myeloma were updated, leading to revised recommendations for imaging modalities and definition of therapy response. This review provides an overview of the current definitions of monoclonal plasma cell disease, diagnostic options, and changes relevant to radiologists.
Method: A pubmed search regarding the multiple myeloma guidelines was conducted, and results were filtered considering publications of international associations and expert reviews.
Background and purpose - There is a lack of information on any associations between the functional outcome and age and diagnosis in patients who have undergone shoulder arthroplasty. We therefore evaluated the functional outcome in "young" and "old" patients treated with either hemiarthroplasty (HA) or total shoulder arthroplasty (TSA) with diverse diagnoses. Patients and methods - The functional results of 496 primary shoulder arthroplasties were analyzed using the Constant score (age- and sex-adjusted) and subjective satisfaction.
View Article and Find Full Text PDFPurpose: Paclitaxel is an antiproliferative agent in drug-eluting stents with largely unknown tissue interaction. Toxicity might result from overdosage and/or accumulation. Part 1 of this two-step study investigated how paclitaxel uptake depends on dose density, coronary drug transfer kinetics, and elution efficacy.
View Article and Find Full Text PDFPurpose: In part 1 of the present study, the authors demonstrated that coronary paclitaxel uptake from drug eluting stents (DESs) was not dependent on exposure time and dose. In this second part, the effect of the different paclitaxel dose densities on long-term biologic behavior was evaluated.
Materials And Methods: In 40 minipigs, (with 4- and 12-week follow-up), identical stents with the same three paclitaxel dose densities as in part 1 were implanted in the right coronary artery.
Purpose: To determine the arterial distribution pattern of the embolic agent Embozene within the porcine kidney and compare it with those of other spherical embolic agents.
Materials And Methods: Embozene, Embosphere, Bead Block, and Contour SE in size classes of 100-300 microm, 500-700 microm, and 700-900 microm and Embozene and Embosphere in the size class of 40-120 microm were used for total arterial occlusion in minipig kidneys. Organs were evaluated microscopically regarding vascular distribution of the different embolic agents and particle sizes.
Purpose: To evaluate the immunohistochemical inflammatory reaction after porcine renal embolization with the new spherical embolic agent Embozene and to compare it with other spherical embolic agents.
Materials And Methods: After superselective porcine renal embolization (40 pigs) with different sizes of embolic agents (Embozene, Embosphere, Bead Block, Contour SE), tissue arrays were obtained (size ranges, 40-120 microm, 100-300 microm, 500-700 microm, 700-900 microm). After immunostaining for CD subtyping (CD45 and CD68) and cytokines (C-reactive protein [CRP] and interleukin-1 beta), a semiquantitative immunoreactivity score was calculated for each marker: intensity of staining was scored between 0 (negative) and 3 (intensive) and extent of staining between 0 and 4 (>80%), indicating the percentage of positive staining.
We sought to describe and compare material specific inflammatory and foreign body reactions after porcine liver embolization with spherical embolic agents. In 40 animals, superselective liver embolization was performed with four different spherical embolic agents of various sizes: 40-120 microm (Embozene, Embosphere), and 100-300 microm, 500-700 microm, and 700-900 microm (Embozene, Embosphere, Bead Block, and Contour SE, respectively). After 4 or 12 weeks, inflammatory reactions were evaluated microscopically according to the Banff 97 classification.
View Article and Find Full Text PDFThe purpose of this study was to investigate the potential of nanoscale coating with the highly biocompatible polymer Polyzene-F (PZF), in combination with cobalt chromium and stainless steel stents, to reduce in-stent stenosis, thrombogenicity, and vessel wall injury and inflammation. One bare cobalt chromium, PZF-nanocoated stainless steel or PZF-nanocoated cobalt chromium stent was implanted in right coronary artery of 30 mini-pigs (4- or 12-week follow-up). Primary study end points were in-stent stenosis and thrombogenicity.
View Article and Find Full Text PDFPurpose: To evaluate the pattern of recanalization and specific inflammatory reaction after superselective embolization with four commercially available spherical embolic agents of different sizes in the mini pig kidney model.
Materials And Methods: In 40 mini pigs, the lower poles of both kidneys were superselectively embolized with Embozene, Embosphere, Bead Block, and Contour SE particles in sizes of 40-120 mircom (Embozene, Embosphere) and 100-300 microm, 500-700 microm, and 700-900 microm (Embozene, Embosphere, Bead Block, Contour SE). After a follow-up time of 4 or 12 weeks, recanalization was determined with angiography.
The objective of this study was to evaluate inflammatory response and recanalization after embolization with a new spherical embolic agent based on a core and shell design with a hydrogel core of polymethylmethacrylate (PMMA) and a Polyzene-F nanoscale coating in a porcine kidney model. Thirty-six minipigs were enrolled for superselective renal embolization. Polyzene-F-coated PMMA particles and uncoated PMMA particles with a diameter of 300-600 mum were used.
View Article and Find Full Text PDFPurpose: To date no direct experimental comparison between the CYPHER-Select and TAXUS-Express stents is available. Therefore, we investigated late in-stent stenosis, thrombogenicity, and inflammation, comparing the CYPHER-Select, TAXUS-Express, and custom-made cobalt chromium Polyzene-F nanocoated stents (CCPS) in the minipig coronary artery model.
Methods: The three stent types were implanted in the right coronary artery of 30 minipigs.