Background: This study prospectively assesses different aspects of short- and long-term quality of life (QoL) after catheter ablation for atrial fibrillation (AF). An analysis of 7 validated generic and tailored questionnaires was performed with regard to the relation of QoL to ablation success.
Methods: The study included 133 patients (74% men, age 57±10) who underwent pulmonary vein isolation ± linear or electrogram-guided substrate modification for AF.
Introduction: Electromagnetic interference with pacemaker and implantable cardioverter defibrillator (ICD) systems may cause temporary or permanent system malfunction of implanted devices. The aim of this study was to evaluate potential interference of a novel magnetic navigation system with implantable rhythm devices.
Methods: A total of 121 devices (77 pacemakers, 44 ICDs) were exposed to an activated NIOBE II® Magnetic Navigation System (Stereotaxis, St.
Aims: Ablation of complex fractionated atrial electrograms (CFAEs) is a new approach for the treatment of atrial fibrillation (AF). The purpose of the study was to assess the efficacy of CFAE ablation as a stand-alone strategy in patients with persistent AF and to compare it with a combined approach of CFAE ablation and pulmonary vein isolation (PVI).
Methods And Results: The study included 77 consecutive patients with persistent AF who underwent radiofrequency (RF) ablation of CFAE as a sole ablation procedure (CFAE group, n = 23 patients) or a combined approach of CFAE ablation and PVI (CFAE plus PVI group, n = 54 patients).
Unlabelled: We report on a 32-year-old man with tricuspid atresia, pulmonary stenosis and hypoplastic right ventricle. He had received a Fontan-Kreutzer procedure (anastomosis between the right atrial appendage and the pulmonary artery) at the age of 14 years. At the age of 2 years, an abdominal VVI-pacemaker with an epicardial ventricular lead had been implanted because of symptomatic third degree AV-block.
View Article and Find Full Text PDFAims: The aim of the study was to investigate the feasibility of performing segmental pulmonary vein (PV) isolation guided by the NavX (Endocardial Solutions, St Jude Medical, Inc., St Paul, MN, USA) system without the three-dimensional (3D) geometric reconstruction option and whether the use of NavX system will reduce the radiation exposure and procedure duration.
Methods And Results: The study included 64 patients with symptomatic paroxysmal or permanent atrial fibrillation, in whom PV isolation was performed using fluoroscopic guidance (n=32) or the NavX system (n=32).
Background: Predictors of atrioventricular nodal reentrant tachycardia (AVNRT) recurrence after radiofrequency ablation including the importance of residual slow pathway conduction are not known. The aim of this study was to report the acute and long-term results of slow pathway ablation in a large series of consecutive patients with AVNRT and to analyze the potential predictors of arrhythmia recurrence with a particular emphasis on the residual slow pathway conduction after ablation.
Methods: The study included 506 consecutive patients with AVNRT (mean age 52.