Publications by authors named "Hector D Barone"

Background: Although endovascular treatment of the thoracic aorta (TEVAR) has become an elective procedure for treatment of complicated type B aortic dissection, its role in treating post dissection thoraco-abdominal aortic aneurysm (TAAA), is still limited. This is a case of aortic vascular disease, which reports the use of a new endovascular device.

Case Presentation: We present the case of a 62 year old male patient with a history of hypertension, active smoker, who presented penetrating descending thoracic aortic ulcer in the setting of a chronic abdominal aortic dissection.

View Article and Find Full Text PDF

Purpose: To report the use of a branched, balloon-deployable stent-graft to treat abdominal aortic aneurysm (AAA) in the setting of a solitary kidney.

Case Report: A 72-year-old man with a solitary intrapelvic kidney and multiple comorbid conditions was diagnosed with an asymptomatic 5.3-cm abdominal aortic aneurysm (AAA); the renal artery emerged from the aneurysm sac.

View Article and Find Full Text PDF

Purpose: To determine the evolution of the proximal aortic neck diameter in mid- to long-term follow-up after endovascular aneurysm repair of abdominal aortic aneurysm (AAA) with a balloon-expandable stent-graft.

Methods: Thirty patients (27 men; average age 71 years, range 56-87) with infrarenal AAAs were treated with the SETA-Latecba balloon-expandable stent-graft (6 aortomonoiliac and 24 bifurcated configurations). Follow-up ranged from 4 to 8 years (mean 73.

View Article and Find Full Text PDF

Twenty-nine modular stent-grafts deployed transrenally to repair AAAs with short necks in dogs were harvested at autopsy of the animals after scheduled durations of implantations of 10 days, one month, three months, and six months. Analyses of the explanted devices included non-destructive techniques such as gross observations, X-rays CT scan, IVUS and angioscopy. Further to appropriate dissection, histological investigations were carried out by means of scanning electron microscopy (SEM) and light microscopy.

View Article and Find Full Text PDF

Severely angulated (> 60 degrees ) or short (< 15 mm) proximal necks remain significant anatomical limitations for endovascular stent-graft repairs for abdominal aortic aneurysms. Ensuring proper proximal fixation of the stent-graft to the host artery without the short-or long-term risks of endoleak or migration represents a particular technical challenge for these anatomical circumstances. An innovative balloon expandable stent combined with a weft-knitted prosthesis was specifically designed for these situations by modelling the stent to the neck anatomy without overdistension or potential barotrauma allowing better incorporation of the device.

View Article and Find Full Text PDF