Early active motion limits adhesion formation and thus improves functional performance after tendon grafting. The early strength of distal fixation is critical to successful tendon grafting. We describe a new Y-tunnel technique of distal fixation and compare it with 2 established methods, the Pulvertaft transverse tunnel and the Bunnell button over the fingernail techniques, in a human cadaver model to determine which is the strongest method.
View Article and Find Full Text PDFTo compare the biomechanical performances of six 4-strand flexor tendon repairs at zone II, we used an in situ testing model in 54 cadaver profundus tendons. The techniques studied were the modified Becker, modified double Tsuge, Lee, locked cruciate, Robertson, and Strickland. Prerepair and postrepair comparisons for work of flexion to a 3.