Background: With the introduction of Doppler-tipped guide wires, intracoronary Doppler flow measurement has been increasingly accepted as an additional diagnostic approach in the catheterization laboratory. However, the safety of intracoronary Doppler flow measurement has not been well-investigated. The purpose of our study was to evaluate the safety of intracoronary Doppler flow measurement using the Doppler FloWire (Cardiometrics, Mountain View, Calif).
View Article and Find Full Text PDFIn Europe more than fifty stents are currently available for the therapy of coronary artery disease. Nonetheless it is unknown whether material and design influence the stent's behavior. We have studied the recoil and dilatation behavior of five currently available stainless steel (316L) stents compared to stent prototypes made of pure titanium.
View Article and Find Full Text PDFBasic Res Cardiol
June 2000
The evaluation of regional myocardial blood flow (RMBF) during cardiac catheterization is of particular diagnostic interest. The purpose of this investigation was to validate x-ray densitometric parameters for the evaluation of RMBF. In five anesthetized dogs, arterial flow in the circumflex coronary artery was measured continuously with an electromagnetic flowmeter, and RMBF was determined by colored microspheres.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
June 2000
Objectives: In order to limit the variability of coronary flow velocity reserve (CFVR), we analyzed which factors independently affect CFVR and established a new parameter integrating these factors.
Background: Coronary flow velocity reserve (CFVR) is a frequently used parameter for evaluating the physiological significance of epicardial stenosis and microvascular function. Since CFVR measurements are done in substantially different hemodynamic and clinical situations, interpretation of CFVR requires correction for major influencing factors.
Catheter Cardiovasc Interv
March 2000
Aims: Evaluation of angiographical and intracoronary Doppler-derived parameters of coronary stenosis severity.
Methods And Results: A total of 225 patients with one-vessel disease were studied before PTCA and at 6 months follow-up. Exercise electrocardiography was performed to document presence (n = 157) or absence (n = 138) of an ST segment shift (> or =0.
Conventional manual compression and subsequent application of pressure bandages is associated with prolonged immobility and significant patient discomfort. Routine anticoagulation as well as the use of new interventional devices and platelet inhibiting strategies lead to a higher incidence of local bleeding complications after diagnostic cardiac catheterization or coronary angioplasty. Immediate sheath removal increases patient comfort.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
February 2000
The hemostatic puncture closure device Angio-Seal is a quick, safe, and easy-to-use system, allowing rapid sealing of the vascular access site following coronary angiography and interventional procedures. It is advantageous for patients in whom early mobilization is desired and may therefore decrease hospital costs. Despite the documented low complication rate, there are some specific problems.
View Article and Find Full Text PDFWe report on a 46-year-old male with unstable angina pectoris due to a total proximal occlusion of the left circumflex artery. At the side of a plaque rupture there was a thrombotic occlusion. With PTCA recanalization was possible, but a dissection occurred, therefore coronary stents were implanted.
View Article and Find Full Text PDFCoronary flow velocity reserve (CFVR) measurement using intracoronary Doppler techniques has been increasing accepted for the assessment of physiological significance of epicardial stenosis and the functional changes after coronary interventions. However, large discrepancy exists concerning the acute changes of CFVR immediately after intervention. The purpose of this study was to investigate the prevalence of microvascular dysfunction in patients with significant coronary artery disease.
View Article and Find Full Text PDFIn about 10 to 30% of patients with typical angina undergoing coronary angiography for suspicion of stenotic coronary artery disease angiographically normal coronary arteries are found. Kemp et al. in 1973 coined the term syndrome X to describe this entity.
View Article and Find Full Text PDFBackground: Intravascular ultrasound (IVUS) offers a new modality by which to image the vessel wall in high resolution. The aim of the study was to classify atherosclerotic lesions using IVUS according to American Heart Association (AHA) recommendation.
Methods: IVUS was performed using a 20 or 30 MHz mechanically rotated catheter in 190 patients (aged from 35 to 75 years, mean 59 +/- 9 years) who presented with suspicion of coronary artery disease based on clinical examination.
Background: Large discrepancies exist concerning the incidence of myocardial bridging. This has been reported to be 0.5%-2.
View Article and Find Full Text PDFRecently, alpha(2)-adrenoceptor activation was shown to play an important role in the vasoconstriction of normal coronary arteries, whereas in the presence of atherosclerosis, the activation of both alpha(1)- and alpha(2)-adrenoceptors reduces coronary blood flow in humans. alpha(2)-Adrenoceptors activate pertussis toxin (PTX)-sensitive G proteins, whereas alpha(1)-adrenoceptors couple to PTX-insensitive G proteins. Thus, the 825T allele of the beta3 subunit of heterotrimeric G proteins, associated with enhanced PTX-sensitive G protein signaling, was expected to determine the alpha(2)-adrenoceptor-, but not the alpha(1)-adrenoceptor-, mediated reduction in coronary blood flow (CBF).
View Article and Find Full Text PDFBackground: Coronary artery remodeling is a common phenomenon in human atherosclerotic arteries. Controversies exist concerning the presence of absence of the remodeling process in diseased human coronary saphenous vein bypass grafts. The purpose of the study was to observe the vessel and lumen dimensions in patients who had undergone saphenous vein grafting with intravascular ultrasound to find out whether the remodeling process exists in the diseased human saphenous vein bypass grafts.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
August 1999
Coating stents with autologous venous grafts has been suggested to prevent problems associated with conventional stenting, but the need for surgical vessel harvest hampered broad application. A novel synthetic coronary stent graft (CSG) overcomes this limitation by a synthetic membrane, fixed between two thin metallic stents. We successfully implanted 21 CSGs in 18 patients for treatment of acute coronary rupture, thrombus-containing lesions, and lesions with plaque rupture or adjacent pseudoaneurysm.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
September 1999
We sought to describe the value of electron beam computed tomography (EBCT) to detect stent restenoses at follow-up and to identify characteristic EBCT features of coronary stents. Six coronary stents (GRII, Jostent, NIR, PS, Micro, Wiktor) were scanned in vitro (10 1. 5-mm-thick slices, 15-cm FoV, 100-ms AT) before and after inflation with 3.
View Article and Find Full Text PDFObjectives: This study evaluated safety and efficacy of excimer laser angioplasty for treatment of restenosed or occluded coronary stents.
Background: Balloon angioplasty of in-stent restenosis is limited by a high recurrence rate. Debulking by laser angioplasty is a novel concept to treat in-stent restenosis.
Chest pain following successful percutaneous coronary interventions is a common problem. Although the development of chest pain after coronary interventions may be of benign character, it is disturbing to patients, relatives and hospital staff. Such pain may be indicative of acute coronary artery closure, coronary artery spasm or myocardial infarction, but may also simply reflect local coronary artery trauma.
View Article and Find Full Text PDFThe objective of this study was to evaluate the potential benefit of stepwise intravascular ultrasound (IVUS)-guided coronary stent deployment compared to angiographic stent implantation with final IVUS assessment only. Acute procedural success and 6-month angiographic follow-up were compared in both groups. Intravascular ultrasound was performed using a 20- or 30-MHz mechanically rotated catheter in 85 patients who were prospectively randomized to group A (n=42; IVUS-guided) and group B (n=43; angiography +/- final IVUS assessment).
View Article and Find Full Text PDFAim: To visualise the characteristics of ruptured plaques by intravascular ultrasound (IVUS) and to correlate plaque characteristics with clinical symptoms to establish a quantitative index of plaque vulnerability.
Methods: 144 consecutive patients with angina were examined using IVUS. Ruptured plaques, characterised by a plaque cavity and a tear on the thin fibrous cap, were identified in 31 patients (group A), of whom 23 (74%) presented with unstable angina.
Background: Although adrenergic activation plays a major role in the initiation of experimental myocardial ischemia, the significance of alpha-adrenergic coronary constriction in humans has been questioned. The present study assessed the impact of selective alpha-adrenergic receptor activation in patients with normal or atherosclerotic coronary arteries.
Methods And Results: In 39 patients, coronary blood flow (CBF, mL/min) was determined from combined angiography and Doppler measurements.
Aims: The purpose of this part of the INTERVENT project was (1) to redefine and individually predict post-procedural complications associated with coronary interventions, including alternative/adjunctive techniques to PTCA and (2) to employ the prognostic INTERVENT computer model to clarify the structural relationship between (pre)-procedural risk factors and post-procedural outcome.
Methods And Results: In a multicentre study, 2500 data items of 455 consecutive patients (mean age: 61.1+/-8.