Publications by authors named "Hatice Bilge"

The present study was undertaken to investigate the suitability of alternative internal target volume (ITV) delineation strategies based on maximum intensity projection (MIP), average intensity projection (AIP), 2 extreme phases and 4 phases images relative to the ITV in stereotactic body radiation therapy (SBRT) for lung cancer. The 4-dimensional computed tomography (4DCT) data of 15 lung cancer patients treated with SBRT in our clinic were used. Five different ITVs were generated as follows: merging GTVs from 10 phases (ITV); merging GTVs from 2 extreme phases (0%, 50%) (ITV); merging GTVs from 4 phases (0%, 20%, 50%, and 70%) (ITV); delineating GTV on MIP (ITV), and delineating GTV on AIP (ITV).

View Article and Find Full Text PDF

In this study we develop an efficient computational procedure that generates medically acceptable treatment plans for volumetric modulated arc therapy with constant gantry speed. Our proposed method is a column generation heuristic based on a mixed integer linear programming model, where the objective function contains minimization of total monitor unit of the treatment plan and dose-volume requirements are included as conditional value-at-risk constraints. Our heuristic generates a full treatment arc for the restricted master problem and calibrates the right hand side parameters of the conditional value-at-risk constraints in the first phase.

View Article and Find Full Text PDF

In radiotherapy, dose distributions are obtained by using dose calculation algorithms that are implanted in treatment planning systems (TPS). This study aims to compare the surface doses of separate field sizes calculated by different version of The Analytical Anisotropic Algorithm (AAA) and measured by the parallel-plate ion chamber that is admitted as the most reliable dosimetry system for the surface region dose measurements. In order to measure the near surface dose, water equivalent solid phantom was used and measurements were made for 6MV photon beam at 100 cm source-detector distance for 5×5, 10×10, and 20×20 cm2 field sizes.

View Article and Find Full Text PDF

The aim of the study was to investigate the effect of the Hybrid technique which was created by combining of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) for the treatment of nasopharyngeal cancer (NPC) patients. 7 to 9 field IMRT, triple arc VMAT, and Hybrid plans were generated for 10 advanced stage NPC patients. The homogeneity index (HI) and the conformity index (CI) of planning target volumes (PTVs) were calculated for each technique to evaluate the plan quality.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to perform pretreatment patient-specific quality assurance (QA) for intracranial irradiation using CyberKnife with an ion chamber.

Methods: Twenty-five intracranial plans created using the ray-tracing algorithm were used for this study. Computed tomography (CT) images of the water-equivalent RW3 slab phantom with PinPoint ionization chamber were acquired with 1-mm slice thickness and transferred to the MultiPlan treatment planning system (TPS).

View Article and Find Full Text PDF

Purpose: This study aims to investigate the factors that reduce fetal dose in pregnant patients with breast cancer throughout their radiation treatment. Two main factors in a standard radiation oncology center are considered as the treatment planning systems (TPSs) and simple shielding for intensity modulated radiation therapy technique.

Materials And Methods: TPS factor was evaluated with two different planning algorithms: Anisotropic analytical algorithm and Acuros XB (external beam).

View Article and Find Full Text PDF

To investigate the dose-volume variations of planning target volume (PTV) and organ at risks (OARs) in eleven prostate cancer patients planned with single and double arc volumetric modulated arc therapy (VMAT) when varying collimator angle. Single and double arc VMAT treatment plans were created using Monaco5.0(®) with collimator angle set to 0°.

View Article and Find Full Text PDF

The aim of this research was to investigate the fetal doses of pregnant patients undergoing conformal radiotherapy or intensity-modulated radiation therapy (IMRT) for breast cancers. An Alderson Rando phantom was chosen to simulate a pregnant patient with breast cancer who is receiving radiation therapy. This phantom was irradiated using the Varian Clinac DBX 600 system (Varian Medical System, Palo Alto, CA) linear accelerator, according to the standard treatment plans of both three-dimensional conformal radiation therapy (3-D CRT) and IMRT techniques.

View Article and Find Full Text PDF

In recent years, small-field electron beams have been used for the treatment of superficial lesions, which requires small circular fields. However, when using very small electron fields, some significant dosimetric problems may occur. In this study, dose distributions and outputs of circular fields with dimensions of 5cm and smaller, for nominal energies of 6, 9, and 15MeV from the Siemens ONCOR Linac, were measured and compared with data from a treatment planning system using the pencil-beam algorithm in electron beam calculations.

View Article and Find Full Text PDF

In this study, the peripheral dose outside the applicator was measured using electron beams produced by an Oncor linear accelerator and compared with the data of the treatment planning system (TPS). The dose profiles have been measured, by using a water-equivalent slab phantom and a parallel plate ionisation chamber, at 6, 9 and 15 MeV energy levels in 5×5, 10×10, 15×15, 20×20 and 25×25 cm(2) applicators and at 0, 10 and 20° gantry angles; and at the surface, 0.2, 0.

View Article and Find Full Text PDF

Purpose: High-energy photons are most commonly used in radiotherapy to treat cancer. Wedge filters are required to obtain homogeneous dose distribution in the patient. Different wedge filter types create different surface doses.

View Article and Find Full Text PDF

The aim of this study is to determine the effect of bolus to the surface dose in oblique electron incidences. Irradiations with 4.5, 6, 7.

View Article and Find Full Text PDF

The aim of this study was to determine the surface doses using GafChromic EBT films and compare them with plane-parallel ionization chamber measurements for 6 and 18 MV high energy photon beams. The measurements were made in a water equivalent solid phantom in the build-up region of the 6 and 18MV photon beams at 100 cm SSD for various field sizes. Markus type plane-parallel ion chamber with fixed-separation between collecting electrodes was used to measure the percent depth doses.

View Article and Find Full Text PDF

The accuracy of the Leksell GammaPlan, the dose planning system of the Gamma Knife Model-B, was evaluated near tissue inhomogeneities, using the gel dosimetry method. The lack of electronic equilibrium around the small-diameter gamma beams can cause dose calculation errors in the neighborhood of an air-tissue interface. An experiment was designed to investigate the effects of inhomogeneity near the paranosal sinuses cavities.

View Article and Find Full Text PDF

The primary goal in this study was to investigate 3-D dose distribution, near the areas of tissue inhomogeneities, in Gamma Knife Radiosurgery with the gel dosimetry. The spherical glass balloon of a diameter of 16 cm filled with the gel forms the homogeneous phantom; and an identical balloon with two corks placed on each side to represent the air cavities forms the inhomogeneous phantom. Dose calibration is performed by irradiating vials at known doses and then utilizing the R2- dose calibration curve.

View Article and Find Full Text PDF

Aim: To evaluate the prevalent topical therapeutic modalities available for the treatment of acute radiation proctitis compared to formalin.

Methods: A total of 120 rats were used. Four groups (n = 30) were analyzed with one group for each of the following applied therapy modalities: control, mesalazine, formalin, betamethasone, and misoprostol.

View Article and Find Full Text PDF

Radiation enteritis occurs during the radiotherapy of many intraabdominal malignancies. Radiation induces cellular injury directly and through the generation of free radicals. In the present study we aimed to investigate the effect of octreotide (OCT) pretreatment in irradiation-induced enteritis.

View Article and Find Full Text PDF

Radiation enteritis is a significant clinical problem in patients receiving ionizing radiation directed to the abdomen or pelvis. Although radiation is aimed to be directed against the malignant tissue, adjacent healthy tissues are also affected. The small intestine is the most sensitive organ to radiation.

View Article and Find Full Text PDF

Background: Radiation rectitis is a major problem associated with high-doseirradiation used for pelvic malignancies.

Objective: The aim of this study was to investigate the possible protectiveeffect of mesalamine against irradiation-induced oxidative tissue damage in an experimental model.

Methods: THREE GROUPS OF FEMALE SPRAGUE DAWLEY RATS WERE ASSIGNED TO RECEIVE TREATMENT AS FOLLOWS: mesalamine enema (60 mg/mL) BID + irradiation (IR) was given to the mesalamine + IR group, and isotonic saline enema BID + irradiation to the control group.

View Article and Find Full Text PDF

We studied the effect of total body X-ray irradiation on the heme oxygenase-1 (HO-1) induction in the livers of young and aged rats. For this purpose, male rats were irradiated with a dose of 17 Gy. The animals were killed 5 h after irradiation.

View Article and Find Full Text PDF

Nitric oxide has many functions in wound healing and metabolism of bone. In the current study the role of nitric oxide on bone healing was investigated. Thirty-six young adult male Sprague-Dawley rats were divided into three groups: control, nitroso-bovine serum albumin, and aminoguanidine.

View Article and Find Full Text PDF