Background: The target volume for postoperative breast irradiation is the remaining breast tissue, and the axillary region is not an intentional target volume.
Patients And Methods: Between 2001 and 2009, eligible women with pT1-2cN0/pN0(sn) breast cancer underwent breast-conserving therapy without axillary dissection. Treatment outcomes between 2 radiotherapy planning groups, high tangent fields with 2-dimensional (2-D) simulation-based planning and 3-dimensional (3-D) computed tomography-based planning with a field-in-field technique, were compared.
Purpose: We analyzed whether axillary nodal irradiation could control clinically node-negative disease, including those patients with a positive sentinel lymph node biopsy (SLNB), most of whom received regional nodal irradiation. We also evaluated toxicity profiles that resulted from nodal irradiation.
Patients And Methods: From 1988 to 2011, 2107 patients with cT1-T2N0M0 breast cancer underwent breast conservation therapy in the absence of axillary dissection: nx group (n = 1548), without any axillary surgery; the sn(-) group (n = 518), with a negative SLNB; and sn(+) group (n = 104), with a positive SLNB.
Purpose: The aim of this study was to evaluate the efficacy and safety of redistributed subclavian arterial infusion chemotherapy (RESAIC). We have focused on the local response, quality of life (QOL), and complications. We have also investigated factors that influence the local response of RESAIC.
View Article and Find Full Text PDFPurpose: To correlate punctate hyperechoic foci (PHF) on ultrasound (US) with microcalcifications detected by mammography (MMG) and at histopathology.
Materials And Methods: Forty-eight subjects who underwent stereotactic vacuum-assisted breast biopsy (SVABB) for evaluation of breast microcalcifications between April and December 2008 were evaluated for 191 lesions obtained after SVABB. The concordance between PHF on US with microcalcifications detected on MMG and histopathology was therefore evaluated for 191 lesions.
Objective: The purpose of this study was to use synchrotron radiation imaging with 6-microm resolution to evaluate amorphous and pleomorphic breast tissue microcalcifications.
Conclusion: Synchrotron radiation imaging depicted microcalcifications as small as 24 microm. Imaging with this technique revealed that most amorphous and pleomorphic calcifications on conventional mammograms are clusters of fine specks and that in addition to the shape or density of a speck, the distribution density of clustered specks is a factor determining the apparent shape.
Purpose: To prospectively evaluate the accuracy of high-resolution (HR)-MRI as a secondary examination in women with abnormal calcifications detected on mammography.
Materials And Methods: We used a 4.7-cm microscopy coil to acquire HR-MRI signal data.
Based on the enzymatic saccharification of the various pulps in the previous 0.8 l ultrasonic stirred tank reactor, the ultrasound-enhanced saccharification of waste papers such as newspaper, carton paper, office paper etc. was carried out in the same reactor as well as larger scale stirred tank reactors of size 3.
View Article and Find Full Text PDFThe breast and ovarian tumor suppressor BRCA1 forms a heterodimeric RING-type ubiquitin ligase with BARD1 to catalyze untraditional Lys-6-linked polyubiquitin chains. It is not clear how the BRCA1-BARD1 ligase regulates various cellular processes such as DNA repair, cell-cycle progression, transcriptional regulation, and centrosome duplication. Here we report that BRCA1-BARD1 catalyzes the polyubiquitination of nucleolar phosphoprotein nucleophosmin/B23 (NPM).
View Article and Find Full Text PDFSynchrotron radiation (SR) imaging of an RMI 156 mammography quality control phantom, serial number 156-15330, revealed some defects which degraded the visibility of calcification specks. SR imaging was performed at SPring-8, in Harima, Japan by using a monochromatic energy of 20 KeV with a field-of-view of 24 X 24 mm. Different kinds of images were obtained by changing sample-to-detector distances; absorption images and refraction-enhanced images.
View Article and Find Full Text PDFThe surgical techniques and clinical results of quadrantectomy as a form of breast-conserving surgery are described. A quadrantectomy is a breast-conserving technique including wide resection and tumorectomy. A quadrantectomy is designed to remove an anatomic segment of breast tissue (duct-lobular system).
View Article and Find Full Text PDFIn Japan the mortality and incidence rates of breast cancer have been increasing. In 2000, the number of breast cancer deaths in female was 9,171. In 1996, the aged adjusted incidence rate of breast cancer was 38.
View Article and Find Full Text PDF