Supercontinuum sources based on intrapulse difference frequency generation (IDFG) from mode-locked lasers open new opportunities in mid-infrared gas spectroscopy. These sources provide high power and ultra-broadband spectral coverage in the molecular fingerprint region with very low relative intensity noise. Here, we demonstrate the performance of such a light source in combination with a multipass cell and a custom-built Fourier transform spectrometer (FTS) for multispecies trace gas detection.

View Article and Find Full Text PDF

Broadband mid-infrared (MIR) spectroscopy is a well-established and valuable diagnostic technique for reactive plasmas. Plasmas are complex systems and consist of numerous (reactive) types of molecules; it is challenging to measure and control reaction specificity with a good sensitivity. Here, we demonstrate the first use of a novel MIR supercontinuum (SC) source for quantitative plasma spectroscopy.

View Article and Find Full Text PDF

The aim of this study was to investigate volatile organic compounds (VOCs) in exhaled breath as possible non-invasive markers to monitor the inflammatory response in inflammatory bowel disease (IBD) patients as a result of repeated and prolonged moderate-intensity exercise. We included 18 IBD patients and 19 non-IBD individuals who each completed a 30, 40, or 50 km walking exercise over three consecutive days. Breath and blood samples were taken before the start of the exercise event and every day post-exercise to assess changes in the VOC profiles and cytokine concentrations.

View Article and Find Full Text PDF

A major challenge for breath research is the lack of standardization in sampling and analysis. To address this, a test that utilizes a standardized intervention and a defined study protocol has been proposed to explore disparities in breath research across different analytical platforms and to provide benchmark values for comparison. Specifically, theinvolves the targeted analysis in exhaled breath of volatile constituents of peppermint oil after ingestion of the encapsulated oil.

View Article and Find Full Text PDF

We present a fast-scanning Fourier transform spectrometer (FTS) in combination with high-repetition-rate mid-infrared supercontinuum sources, covering a wavelength range of 2-10.5 µm. We demonstrate the performance of the spectrometer for trace gas detection and compare various detection methods: baseband detection with a single photodetector, baseband balanced detection, and synchronous demodulation at the repetition rate of the supercontinuum source.

View Article and Find Full Text PDF

We present a multi-species trace gas sensor based on a fast, compact home-built Fourier transform spectrometer (FTS) combined with a broadband mid-infrared supercontinuum (SC) source. The spectrometer covers the spectral bandwidth of the SC source (2 - 4 µm) and provides a best spectral resolution of 1 GHz in 6 seconds. It has a detection sensitivity of a few hundred of ppbv Hz for different gas species.

View Article and Find Full Text PDF

Volatile organic compounds (VOCs) in exhaled breath provide insights into various metabolic processes and can be used to monitor physiological response to exercise and medication. We integrated and validated in situ a sampling and analysis protocol using proton transfer reaction time-of-flight mass spectrometry (PTR-ToF-MS) for exhaled breath research. The approach was demonstrated on a participant cohort comprising users of the cholesterol-lowering drug statins and non-statin users during a field campaign of three days of prolonged and repeated exercise, with no restrictions on food or drink consumption.

View Article and Find Full Text PDF

Conventional mechanical Fourier Transform Spectrometers (FTS) can simultaneously measure absorption and dispersion spectra of gas-phase samples. However, they usually need very long measurement times to achieve time-resolved spectra with a good spectral and temporal resolution. Here, we present a mid-infrared dual-comb-based FTS in an asymmetric configuration, providing broadband absorption and dispersion spectra with a spectral resolution of 5 GHz (0.

View Article and Find Full Text PDF

We present a multi-species trace gas sensor based on a high-repetition-rate mid-infrared supercontinuum source, in combination with a 30 m multipass absorption cell, and a scanning grating spectrometer. The output of the spectrometer is demodulated by a digital lock-in amplifier, referenced to the repetition rate of the supercontinuum source. This improved the detection sensitivity of the system by a factor 5, as compared to direct baseband operation.

View Article and Find Full Text PDF

The production of volatile organic compounds (VOCs) during programmed cell death (PCD) is still insufficiently studied and their implication in the process is not well understood. The present study demonstrates that the release of VOSCs with presumed antioxidant capacity (methanethiol, dimethylsulfide and dimethyldisulfide) accompanies the cell death in chemical-stressed tobacco BY-2 suspension cultured cells. The cells were exposed to cell death inducers of biotic nature mastoparan (MP, wasp venom) and camptothecin (CPT, alkaloid), and to the abiotic stress agent CdSO.

View Article and Find Full Text PDF

Dual-comb spectroscopy can provide broad spectral bandwidth and high spectral resolution in a short acquisition time, enabling time-resolved measurements. Specifically, spectroscopy in the mid-infrared wavelength range is of particular interest, since most of the molecules have their strongest rotational-vibrational transitions in this "fingerprint" region. Here we report time-resolved mid-infrared dual-comb spectroscopy, covering ~300 nm bandwidth around 3.

View Article and Find Full Text PDF

Recent advancements of mid-infrared (MIR) supercontinuum light sources have opened up new possibilities in laser-based trace gas sensing. While the supercontinuum sources inherently support wide spectral coverage, the detection of broadband absorption signals with high speed and low cost is traditionally limited by the MIR detector arrays. In this work, we demonstrate that this limitation can be circumvented by upconverting the MIR signal into the near-infrared (NIR) region, where cost-effective silicon-based detector arrays can be utilized to measure broadband absorption.

View Article and Find Full Text PDF

We demonstrate an absolute-frequency-calibrated mid-infrared dual-comb spectrometer by using a reference absorption cell. The source is based on a singly-resonant OPO containing two MgO:PPLN crystals in a common ring cavity, synchronously pumped by two mode-locked Yb-fiber lasers. The repetition-rate of the two pumps are stabilized while their offset frequencies and the OPO cavity length are not actively controlled.

View Article and Find Full Text PDF

This joint feature issue of Optics Express and Applied Optics highlights contributions from authors who presented their latest research at the OSA Light, Energy and the Environment Congress, held in Sentosa Island, Singapore from 5 to 8 November 2018. The joint feature issue comprises 11 contributed papers, which expand upon their respective conference proceedings. The published papers introduced here cover a broad range of timely research topics in optics and photonics for lighting and illumination, solar energy, hyperspectral imaging, and environmental sensing.

View Article and Find Full Text PDF

Nitrate and ammonia deferentially modulate primary metabolism during the hypersensitive response in tobacco. In this study, tobacco RNAi lines with low nitrite reductase (NiRr) levels were used to investigate the roles of nitrite and nitric oxide (NO) in this process. The lines accumulate NO2-, with increased NO generation, but allow sufficient reduction to NH4+ to maintain plant viability.

View Article and Find Full Text PDF

This joint feature issue of Optics Express and Applied Optics highlights contributions from authors who presented their latest research at the OSA Light, Energy and the Environment Congress, held in Sentosa Island, Singapore from 5-8 November 2018. The joint feature issue comprises 11 contributed papers, which expand upon their respective conference proceedings. The published papers introduced here cover a broad range of timely research topics in optics and photonics for lighting and illumination, solar energy, hyperspectral imaging, and environmental sensing.

View Article and Find Full Text PDF

We present a fully integrated and transportable multi-species trace gas sensor based on a mid-infrared (MIR) supercontinuum light source. The high brightness (surpassing synchrotron) and ultra-broad spectral bandwidth (2-4 μm) of this light source allows simultaneous detection of multiple broadband absorbing gas species. High sensitivity in the sub-ppmv level has been achieved by utilizing an astigmatic multipass cell.

View Article and Find Full Text PDF

Collision-induced absorption between O2 and CO2 molecules associated with the a1Δg (v = 1) ← X3Σ-g (v = 0) band of oxygen around 1060 nm was measured using cavity ring-down spectroscopy. The lineshape for this transition is measured for the first time, and the integrated cross-section is found to be smaller than the only previous report. For pure oxygen, we find an integrated absorption value of (2.

View Article and Find Full Text PDF

In the field of laser-based absorption spectroscopy, off-axis integrated cavity output spectroscopy is considered to be a sensitive and robust method, employing a simple optical design. However, one of the major drawbacks of non-mode-matched cavities combined with highly reflective mirrors (>99.98%) is its low output intensity.

View Article and Find Full Text PDF

We employed a single-mode, widely tunable (~300 cm) external-cavity quantum cascade laser operating around 8 µm for broadband direct absorption spectroscopy and wavelength modulation spectroscopy where a modulation frequency of 50 kHz was employed with high modulation amplitudes of up to 10 GHz. Using a compact multipass cell, we measured the entire molecular absorption band of acetone at ~7.4 µm with a spectral resolution of ~1 cm.

View Article and Find Full Text PDF

Despite the established importance of nitric oxide (NO) in many physiological and molecular processes in plants, most methods for quantifying NO are open to criticism This reflects the differing methods either lacking specificity or sensitivity, or even from an undue dependence of results on experimental conditions (i.e., chemical concentrations, pH, etc.

View Article and Find Full Text PDF

A 3D ray tracing model is used to simulate optical reinjection in a nonresonant optical cavity, for off-axis integrated cavity output spectroscopy. The optical cavities are optimized for maximum intensity enhancement factors via a grid search and a genetic algorithm. Intensity enhancement factors up to 1400 are found for short cavities (3 cm) and up to 101 for long cavities (50 cm).

View Article and Find Full Text PDF

Detection and analysis of volatile compounds in exhaled breath represents an attractive tool for monitoring the metabolic status of a patient and disease diagnosis, since it is non-invasive and fast. Numerous studies have already demonstrated the benefit of breath analysis in clinical settings/applications and encouraged multidisciplinary research to reveal new insights regarding the origins, pathways, and pathophysiological roles of breath components. Many breath analysis methods are currently available to help explore these directions, ranging from mass spectrometry to laser-based spectroscopy and sensor arrays.

View Article and Find Full Text PDF

Nitric oxide (NO) is a key messenger in plant stress responses but its exact role in drought response remains unclear. To investigate the role of NO in drought response we employed transgenic barley plants (UHb) overexpressing the barley non-symbiotic hemoglobin gene HvHb1 that oxidizes NO to NO. Reduced NO production under drought conditions in UHb plants was associated with increased drought tolerance.

View Article and Find Full Text PDF

Increasing demand for field instruments designed to measure gas composition has strongly promoted the development of robust, miniaturized and low-cost handheld absorption spectrometers in the mid-infrared. Efforts thus far have focused on miniaturizing individual components. However, the optical absorption path that the light beam travels through the sample defines the length of the gas cell and has so far limited miniaturization.