There may be inter-/intra-surgeon variability in the repair of congenital heart defects. The objective was to analyze and visualize inter-/intra-surgeon variability in the level of patch suture lines and in the shape and size of patches developed through surgical simulation for partial anomalous pulmonary venous connection (PAPVC) repair using a patient-specific 3D-printed heart model. A patient with PAPVC and preoperative computed tomography data were selected, and a patient-specific heart model was obtained.