Publications by authors named "Haochen Kang"

Objective: Current shear wave elastography methods primarily focus on 2D imaging. To explore mechanical properties of biological tissues in 3D, a four-dimensional (4D, x, y, z, t) ultrasound shear wave elastography is required. However, 4D ultrasound shear wave elastography is still challenging due to the limitation of the hardware of standard ultrasound acquisition systems.

View Article and Find Full Text PDF

Retinal degeneration, a leading cause of irreversible low vision and blindness globally, can be partially addressed by retina prostheses which stimulate remaining neurons in the retina. However, existing electrode-based treatments are invasive, posing substantial risks to patients and healthcare providers. Here, we introduce a completely noninvasive ultrasonic retina prosthesis, featuring a customized ultrasound two-dimensional array which allows for simultaneous imaging and stimulation.

View Article and Find Full Text PDF

Bionic multifunctional structural materials that are lightweight, strong, and perceptible have shown great promise in sports, medicine, and aerospace applications. However, smart monitoring devices with integrated mechanical protection and piezoelectric induction are limited. Herein, we report a strategy to grow the recyclable and healable piezoelectric Rochelle salt crystals in 3D-printed cuttlebone-inspired structures to form a new composite for reinforcement smart monitoring devices.

View Article and Find Full Text PDF

High element density and strict constraints of the element's size have significantly limited the design and fabrication of 2-D ultrasonic arrays, especially fully sampled 2-D arrays. Recently, 3-D printing technology has been one of the most rapidly developing fields. Along with the great progress of 3-D printing technology, complex and detailed 3-D structures have become readily available with a short iteration cycle, which allows us to reduce the complexity of routing and helps to ameliorate assembly problems in 2-D ultrasound array fabrication.

View Article and Find Full Text PDF

Argus II retinal prosthesis is the US Food and Drug Administration (FDA) approved medical device intended to restore sight to a patient's blind secondary to retinal degeneration (i.e., retinitis pigmentosa).

View Article and Find Full Text PDF

Large aperture ultrasonic arrays can be implemented by tiling together multiple pretested modules of high-density acoustic arrays with closely integrated multiplexing and buffering electronics to form a larger aperture with high yield. These modular arrays can be used to implement large 1.75D array apertures capable of focusing in elevation for uniform slice thickness along the axial direction which can improve image contrast.

View Article and Find Full Text PDF

Electronic visual prostheses, or biomimetic eyes, have shown the feasibility of restoring functional vision in the blind through electrical pulses to initiate neural responses artificially. However, existing visual prostheses predominantly use wired connections or electromagnetic waves for powering and data telemetry, which raises safety concerns or couples inefficiently to miniaturized implant units. Here, we present a flexible ultrasound-induced retinal stimulating piezo-array that can offer an alternative wireless artificial retinal prosthesis approach for evoking visual percepts in blind individuals.

View Article and Find Full Text PDF

Ultrasound single-beam acoustic tweezer system has attracted increasing attention in the field of biomechanics. Cell biomechanics play a pivotal role in leukemia cell functions. To better understand and compare the cell mechanics of the leukemia cells, herein, we fabricated an acoustic tweezer system in-house connected with a 50-MHz high-frequency cylinder ultrasound transducer.

View Article and Find Full Text PDF

Ultrasound medical imaging is an entrenched and powerful tool for medical diagnosis. Image quality in ultrasound is mainly dependent on performance of piezoelectric transducer elements, which is further related to the electromechanical performance of the constituent piezoelectric materials. With rising need for piezoelectric materials with better performance and low cost, a highly 〈001〉 textured piezo ceramic, Pb(Mg1/3Nb2/3)O3-Pb(Zr, Ti)O3, has been developed.

View Article and Find Full Text PDF
Article Synopsis
  • Acoustic Radiation Force Optical Coherence Elastography (ARF-OCE) has been effectively used to assess soft tissue properties like the cornea and retina with high resolution, but existing OCE methods have limitations in spatial and temporal control.
  • A new technique called 2-D ultrasonic array-based OCE imaging combines the benefits of dynamic electronic steering and high-resolution optical coherence tomography (OCT) to improve accuracy in mapping biomechanical properties.
  • Validation and experiments on rabbit corneal tissue show that this innovative approach has the potential to be an important diagnostic tool in ophthalmology.
View Article and Find Full Text PDF

Purpose: To quantitatively investigate both optic nerve head (ONH) and peripapillary sclera (PPS) biomechanical properties of porcine eyes through an ultrasonic elastography imaging system in response to both increasing and decreasing intraocular pressure (IOP).

Methods: The Young's modulus of the ONH and PPS were assessed using our high resolution ultrasonic imaging system which utilized a mechanical shaker to induce shear waves and an off-axis aligned 40 MHz needle transducer to track micron-level displacement along the direction of wave propagation. In this study, imaging on a total of 8 ex vivo porcine eyes preloaded with IOPs from 6 mmHg to 30 mmHg was performed.

View Article and Find Full Text PDF

Since the emergence of the COVID-19 pandemic in December of 2019, clinicians and scientists all over the world have faced overwhelming new challenges that not only threaten their own communities and countries but also the world at large. These challenges have been enormous and debilitating, as the infrastructure of many countries, including developing ones, had little or no resources to deal with the crisis. Even in developed countries, such as Italy, health systems have been so inundated by cases that health care facilities became oversaturated and could not accommodate the unexpected influx of patients to be tested.

View Article and Find Full Text PDF

Thermoelectric generators (TEGs) provide a unique solution for energy harvesting from waste heat, presenting a potential solution for green energy. However, traditional rigid and flexible TEGs cannot work on complex and dynamic surfaces. Here, we report a stretchable TEG (S-TEG) (over 50% stretchability of the entire device) that is geometrically suitable for various complex and dynamic surfaces of heat sources.

View Article and Find Full Text PDF

Objective: The choroidal vessels, which supply oxygen and nutrient to the retina, may play a pivotal role in eye disease pathogenesis such as diabetic retinopathy and glaucoma. In addition, the retrobulbar circulation that feeds the choroid shows an important pathophysiologic role in myopia and degenerative myopia. Owing to the light-absorbing retinal pigment epithelium (RPE) and optically opaque sclera, choroidal and retrobulbar vasculature were difficult to be observed using clinically accepted optical coherence tomography angiography (OCT-A) technique.

View Article and Find Full Text PDF

Tiled modular 2-D ultrasound arrays have the potential for realizing large apertures for novel diagnostic applications. This work presents an architecture for fabrication of tileable 2-D array modules implemented using 1-3 composites of high-bandwidth (BW) PIN-PMN-PT single-crystal piezoelectric material closely coupled with high-voltage CMOS application-specific integrated circuit (ASIC) electronics for buffering and multiplexing functions. The module, which is designed to be operated as a λ -pitch 1.

View Article and Find Full Text PDF

Objective: To explore the protective mechanism of Fengshiqing Recipe (FR) against bone destruction in collagen-induced arthritis (CIA) rats.

Methods: Rats were divided into four groups in the experiment,i.e.

View Article and Find Full Text PDF