Ten stable loci for freezing tolerance (FT) in wheat were detected by genome-wide association analysis. The putative candidate gene TaRPM1-7BL underlying the major locus QFT.ahau-7B.
View Article and Find Full Text PDFPurpose: To commission MCsquare (a multi-cores CPU-based dose calculation engine) for pencil beam scanning (PBS) proton therapy, integrate it into RayStation treatment plan system (TPS) to create a dedicated platform for fast independent dose verification.
Method: A MCsquare-based independent dose verification platform (MC2InRS) was developed to realize automatic dose re-calculation for clinical use, including data preparation, dose calculation, 2D/3D gamma analysis. MCsquare was commissioned based on in-air lateral dose profiles, integrated depth dose, and the absolute dose of different beam energies for ProteusONE.
Zhongguo Yi Liao Qi Xie Za Zhi
June 2021
Aiming at the problem of timeliness of CBCT reconstruction, a CBCT fast short scan reconstruction method is proposed. At the same time, the image reconstruction process in which a new attenuation compensation algorithm is applied to improve image quality. When performing FDK three-dimensional reconstruction of a single-frame acquisition image, the Parker-weighted image is calculated in real time, and a new attenuation compensation algorithm is applied in the back projection process to complete the short scan Parker-weighted reconstruction.
View Article and Find Full Text PDF3D/3D image registration in IGRT, which aligns planning Computed Tomography (CT) image set with on board Cone Beam CT (CBCT) image set in a short time with high accuracy, is still a challenge due to its high computational cost and complex anatomical structure of medical image. In order to overcome these difficulties, a new method is proposed which contains a coarse registration and a fine registration. For the coarse registration, a supervised regression convolutional neural networks (CNNs) is used to optimize the spatial variation by minimizing the loss when combine the CT images with the CBCT images.
View Article and Find Full Text PDFZhongguo Yi Liao Qi Xie Za Zhi
January 2019
In order to improve the speed and accuracy of cone beam CT image quality assurance, an automatic image quality assurance software based on feature extraction is designed and implemented. This paper introduces how the software can realize the positioning of Catphan500 phantoms and the selection of ROI in each module through Canny algorithm and Hough transform circle detection. For the different modules in the Catphan500 phantom, this paper describes the calculation methods of HU accuracy, spatial linearity, HU uniformity and spatial linearity in the software.
View Article and Find Full Text PDF