Unlabelled: This multicenter prospective cohort study assessed the safety and performance of the Trabecular Metal Total Ankle System (TM Ankle; Zimmer) for primary total ankle arthroplasty (TAA).
Methods: One hundred and twenty-one consecutive patients qualifying for primary TAA were enrolled in the study. All patients received the TM Ankle implant.
Background: Peri-implant osteolysis is one of the major complications related to total ankle replacement. The aim of this study was to investigate the short- to midterm incidence of peri-implant osteolysis using computed tomography (CT) as imaging method for the Trabecular Metal Total Ankle (TMTA) implant representing a novel total ankle replacement (TAR) implant design regarding material and surgical technique.
Methods: In total, 104 consecutive patients who had a primary TMTA replacement between March 2013 and October 2017 were included in the study.
Background: The range of motion (ROM) in reverse shoulder arthroplasty (RSA), is mechanically limited by the surrounding bony obstacles especially in abduction and rotation planes. However, the clinical effect of implant positioning, prosthesis design, and individual differences in bone morphology, on ROM is obscure. The aim of this study was to investigate the correlation between radiographic geometry and clinical glenohumeral (GH) ROM after RSA.
View Article and Find Full Text PDFBackground: To measure the motion of polyethylene insert and implant components of mobile-bearing total ankle replacement (TAR) by cone-beam CT scanning.
Methods: 10 TAR patients with high amount of clinical motion after the CCI implant (Ceramic Coated Implant; Wright Medical Technology, Arlington, TN, USA) with average age at operation 64,3 years (range 47-84) and average clinical total range of motion 42 degrees (range 35-55) were included.
Results: The average total range of motion between the insert and the tibial component was 0.
Eur J Orthop Surg Traumatol
August 2021
Background: The semi-constrained Discovery® Elbow System (LimaCorporate, San Daniele del Friuli, Italy) allows varus-valgus laxity of 7° [8]. It has been reported to provide good pain relief and increased range of motion [5, 9] on mid-term follow-up. The aim of the study was to evaluate long-term outcomes of total elbow arthroplasty using the Discovery® Elbow System (LimaCorporate, San Daniele del Friuli, Italy).
View Article and Find Full Text PDFBackground: Total ankle arthroplasty is an alternative for arthrodesis. The objective of this study was to investigate the safety of trabecular-metal ankle prosthetic system with transfibular approach and external frame and its association with changes in clinical and functional scores.
Methods: Between May 2013 and June 2017, a total of 104 consecutive patients underwent primary total ankle arthroplasty with a trabecular metal implant.
Background: We retrospectively evaluated the medium-term follow-up of bone grafting due to periprosthetic osteolytic lesions in ankles.
Methods: 34 ankles (32 patients) with total ankle arthroplasty (TAA) underwent re operation. Indications were large periprosthetic osteolytic lesions or continuous growing of the lesions.
Background: The study reports the medium to long-term results of 130 Ankle Evolutive System total ankle replacements operated at a single-centre. Previously high amount of peri-implant osteolysis was reported from the same material.
Methods: Between 2002 and 2008 one hundred and thirty consecutive ankles replaced with AES ankle prosthesis were followed both radiologically and clinically.
Background: The purpose of this study was to evaluate the long-term results of the Scandinavian Total Ankle Replacement (STAR) implant in a single center.
Methods: Between 1997 and 2002, 34 consecutive ankles were replaced with the STAR ankle prosthesis and reviewed in 2016. Patients were followed both radiologically and clinically; clinical outcomes were measured with the Kofoed ankle score and subjective measurements.
Objectives: To evaluate the trajectory of the change in range of motion after reverse shoulder joint replacement during 3-year follow-up among patients with rheumatoid arthritis.
Methods: Retrospective cohort longitudinal study of 76 shoulder replacements performed in a university clinic. The range of shoulder motion was assessed by a physiotherapist using a manual goniometer with 5-degree precision before the surgery and 1, 3, 6, 12, and 36 months postoperatively.
Background: The major longer term complications of ankle arthroplasty are periprosthetic osteolysis and aseptic loosening. Follow-up studies of total hip arthroplasties show that measurements of periprosthetic osteolytic lesions on radiographs underestimate the size compared with those made on computed tomography (CT), and some of the lesions may even remain undetected on radiographs. However, it is unclear whether the same applies to total ankle arthroplasty (TAA).
View Article and Find Full Text PDFPurpose: Body mass index (BMI) has a significant effect on the spread of sensory spinal block in rheumatoid patients. We tried to achieve the same spread of spinal block for patients in three different BMI groups and, on the basis of the results from a preliminary study, used a simple method feasible for clinical practice. We hypothesized that BMI-related inverse dosing of plain bupivacaine according to low, normal, and high BMI would result in no difference in block extent.
View Article and Find Full Text PDF