Publications by authors named "Hanns Plenk"

The main obstacle in realization of a totally implantable hearing aid is a lack of reliable implantable microphone. In this paper we have described a potentially miniature fiber-optic vibrometer based on a modified Michelson interferometer, designed to serve as a middle-ear microphone for totally implantable cochlear- or middle-ear hearing aids. A model of the sensing system was used for in-vitro and in-vivo investigation of acoustical response of sheep's middle-ear ossicles.

View Article and Find Full Text PDF

Conclusion: The intraoperative application of glucocorticoid-loaded hydrogels seems to cause a reduction in neutrophil infiltration. No beneficial effect on hearing thresholds was detected.

Objectives: To evaluate the application of dexamethasone- and triamcinolone acetonide-loaded hydrogels for effects on hearing preservation and foreign body reaction in a guinea pig model for cochlear implantation (CI).

View Article and Find Full Text PDF

Detailed knowledge of histomorphology is a prerequisite for the understanding of function, variation, and development. In bats, as in other mammals, penis and baculum morphology are important in species discrimination and phylogenetic studies. In this study, nondestructive 3D-microtomographic (microCT, µCT) images of bacula and iodine-stained penes of Pipistrellus pipistrellus were correlated with light microscopic images from undecalcified surface-stained ground sections of three of these penes of P.

View Article and Find Full Text PDF

Objectives: CT assessment of the entire course of the inferior alveolar artery (IAA) within the mandibular canal.

Methods: After contrast medium injection (180 or 400 mg/ml iodine concentration) into the external carotid arteries of 15 fresh human cadaver heads, the main IAA's position in the canal (cranial, buccal, lingual or caudal) was assessed in dental CT images of partially edentulous mandibles.

Results: The course of the main IAA could be followed at both iodine concentrations.

View Article and Find Full Text PDF

The biocompatibility of all metallic, polymeric, or ceramic materials used for functional electrical stimulation is governed by the inevitable inflammatory tissue response, but possibly also by immunological reactions to the bulk material or released constituents. Besides chemical, physical, and corrosion properties of the conductive electrode materials, increased surface area and roughness of the electrode can influence tissue contact and signal delivery, and can also affect electrode-tissue impedance due to increased connective tissue encapsulation. The polymeric materials used for electrode insulation and those for leads and stimulator packaging seem more or less compatible in an aggressive biological environment.

View Article and Find Full Text PDF

For the first time, the histomorphology of the penis bone of a bat (Plecotus austriacus) was examined in detail. From Plecotus austriacus, 14 whole penes and 11 isolated bacula were studied and compared to bacula of Plecotus auritus and Plecotus macrobullaris. The baculum was located on specimen microradiographs and in micro-CT images in the tip of the penis.

View Article and Find Full Text PDF

Objectives: A new method is introduced for the esthetic evaluation of the periimplant mucogingival complex through collection of standardized oral photographs and computer-assisted measurement of reproducible data. Using this method, different soft tissue and crown parameters in the dentogingival complex can be measured and the esthetic outcome monitored.

Material And Methods: A photographic device for standardized oral photography and a standard protocol for the esthetic evaluation of the crown-mucogingival complex is presented, comprising six soft tissue parameters: (1) mesial and (2) distal papilla areas, (3) mesial and (4) distal papilla heights, (5) soft tissue-crown perimeter, and (6) gingival recession.

View Article and Find Full Text PDF

Scanning Electron Microscopy (SEM) revealed that the palate of Cuora amboinensis has a flat surface with keratinized and non-keratinized regions. Keratinization is reflected in disc-shaped keratinized dead cells with rough microplicae on the surface, and is concentrated close to the rhamphotheca. The surface of the non-keratinized hexagonal epithelial cells is dotted with microvilli and sometimes with cilia.

View Article and Find Full Text PDF

Purpose: Radiation therapy influence on bone healing around 3 types of endosseous dental implants in dogs was evaluated.

Materials And Methods: Implants with 3 different surfaces (A = machined commercially pure titanium screws, B = commercially pure titanium plasma spray-coated cylinders, C = hydroxyapatite [HA] -ceramic coated cylinders) were first implanted unilaterally into the right posterior edentulous mandibles of 7 dogs as nonirradiated controls. After 12 weeks without functional loading and after sequential fluorochrome labeling these implants were retrieved by block dissection.

View Article and Find Full Text PDF

Objective: Occlusion rates (OR) and coil densities were quantified by computer-assisted morphometry on angiograms and histological ground sections of coil-embolized experimental aneurysms. The aims of this study were 1) to develop computer-assisted evaluations of angiographic OR and histometrical OR, 2) to compare these results to subjectively estimated angiographic OR from clinical practice, and 3) to test the correlation between histometrical data of coil density and occlusion.

Methods: Eight rabbit carotid-bifurcation aneurysms had been followed by digital subtraction angiography (DSA) before and after Guglielmi detachable coil embolization and at sacrifice (1 h to 24 wk postembolization).

View Article and Find Full Text PDF

The purpose of this study was to compare the periapical tissue responses and cementum regeneration in response to three widely used root-end filling materials, amalgam, SuperEBA, and Mineral Trioxide Aggregate (MTA). These materials were placed using modern microsurgical techniques on endodontically treated dog premolars and molars. After 5 months, the cell and tissue reactions of surface-stained un-decalcified ground sections were evaluated by light microscopy and statistically analyzed.

View Article and Find Full Text PDF

Objectives: Soft and hard tissue healing around submerged and nonsubmerged versions of one dental implant design was evaluated in an experimental canine peri-implantitis model.

Material And Methods: Forty-eight c.p.

View Article and Find Full Text PDF

The aim of this study was to lengthen the sheep mandible with a fully buried device and to quantitatively analyze the tissue regenerate in the distraction gap by means of two-dimensional and three-dimensional histomorphometry. A custom-made device for continuous distraction was used in five adult sheep and fixed with three bicortical screws on either side of an osteotomy, anterior to the premolar region of the mandible. A cable-connected power and control unit was implanted in the neck region.

View Article and Find Full Text PDF

Purpose: To evaluate the feasibility and efficacy of the local application of a replication-defective adenovirus construct for the expression of the antiinflammatory protein I kappa B alpha, inhibitor of nuclear factor kappa B (NF-kappa B), to reduce neointimal formation after stent placement.

Materials And Methods: Nitinol stents were implanted in the iliac arteries of hypercholesterolemic rabbits, followed by balloon dilation (30 seconds at 6 atm). Local adenovirus-mediated transfer of I kappa B alpha (3 mL of 10(9) plaque-forming units per milliliter at 6 atm) was performed and compared with three control groups: stent alone, stent plus local delivery of phosphate-buffered saline (PBS) (3 mL at 6 atm), and stent plus local delivery of control adenovirus coding for green fluorescent protein (GFP) (3 mL of 10(9) plaque-forming units per milliliter at 6 atm).

View Article and Find Full Text PDF